Plan Review Details - Permit 14120822
Plan Review Stops For Permit 14120822
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-01-20 Cont ID  
Sent By shill Date 2015-01-20 Time 18:26 Rev Time 0.00
Received By shill Date 2015-01-20 Time 18:26 Sent To  
Notes
2015-01-20 18:27:11SUBSTANTIAL IMPROVEMENT WHEN RENOVATION IS SUBMITTED
 RENOVATION WILL COMPLY PER ARCHITECT
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-12-30 Cont ID  
Sent By shill Date 2014-12-30 Time 12:12 Rev Time 0.00
Received By shill Date 2014-12-30 Time 12:12 Sent To  
Notes
2014-12-30 12:12:50SEE COMMENTS IN NFIP REVIEW
  
  
2014-12-29 16:33:22TO SHILL DESK.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-01-09 Cont ID  
Sent By skennedy Date 2015-01-09 Time 13:16 Rev Time 0.00
Received By skennedy Date 2015-01-09 Time 13:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-12-30 Cont ID  
Sent By dhayes Date 2014-12-30 Time 13:50 Rev Time 0.00
Received By dhayes Date 2014-12-30 Time 13:50 Sent To  
Notes
2014-12-30 13:50:5212/30/2014
 PROJECT: FLAGLER SOUTH RESIDENCE
 PERMIT#: 14120822
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 PROVIDE BASIC ELMENTS OF ELECTRICAL DEMOLITION TO
 INCLUDE THE FOLLOWING:
  
 1) THE LOCATION OF THE ELECTRICAL SERVICE,
 DISCONNECT(S), AND PANEL(S).
 2) LOCATION AND SOURCE OF TEMPORARY POWER FOR
 DEMOLITION/RENNOVATION.
 3) DETAIL OF LIGHTING AFFECTED BY DEMOLITION. INCLUDE
 LIGHTING AND SWITCHES THAT WILL REMIAN AND LIGHTING AND
 SWITCHES THAT WILL BE REMOVED TO INCLUDE THE SAFE
 TERMINATION OF DEMOLISHED CIRCUITRY BACK TO THE NEAREST
 SOURCE.
 4) PROVIDE THE SAME DETAILS FOR THE SAFE REMOVAL
 RECEPTACLE OUTLETS, MECHANICAL EQUIPMENT, WATER HEATER,
 APPLIANCES AND CIRCUITRY AFFECTED BY DEMOLITION AND THE
 TERMINATION OF CIRCUITRY BACK TO THE NEAREST SOURCE.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-01-20 Cont ID  
Sent By shill Date 2015-01-20 Time 18:27 Rev Time 0.00
Received By shill Date 2015-01-09 Time 13:07 Sent To  
Notes
2015-01-12 12:53:48TO SAK DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-12-30 Cont ID  
Sent By dhayes Date 2014-12-30 Time 14:00 Rev Time 0.00
Received By dhayes Date 2014-12-30 Time 12:25 Sent To  
Notes
2014-12-30 12:25:19TO DAH DESK
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status P Date 2015-01-12 Cont ID  
Sent By shill Date 2015-01-12 Time 12:53 Rev Time 0.00
Received By shill Date 2015-01-12 Time 12:50 Sent To  
Notes
2015-01-12 12:53:32SUBSTANTIAL IMPROVEMENT WHEN RENOVATION IS SUBMITTED
 RENOVATION WILL COMPLY PER ARCHITECT
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2014-12-30 Cont ID  
Sent By shill Date 2014-12-30 Time 10:22 Rev Time 0.00
Received By shill Date 2014-12-30 Time 10:22 Sent To  
Notes
2014-12-30 10:42:03****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. WITHOUT INFORMATION REGARDING THE ENTIRE PROJECT, IT
 CANNOT BE DETERMINED WHETHER OR NOT THIS CONSTITUTES A
 SUBSTANTIAL IMPROVEMENT. HOWEVER, DUE TO THE SCOPE OF
 THE PROPOSED DEMOLITION, IT APPEARS THAT THIS PROJECT
 WILL BE CONSIDERED A SUBSTANTIAL IMPROVEMENT. SEE THE
 CITY OF WEST PALM BEACH MUNICIPAL CODE 94-546(B), FBC
 2010 EXISTING BUILDING 202, 601.3, 1003.5.
  
 COMPLIANCE WITH THE REQUIREMENTS FOR SUBSTANTIAL
 IMPROVEMENT ARE TO BE INCORPORATED INTO THE PERMIT
 DOCUMENTS, EITHER BY REVISING THE SHEETS SUBMITTED OR
 PROVIDING A NEW PAGE.
  
 THE SURVEY SHOWS FFE AT FRONT DOOR = 8.99', LOWER FLOOR
 = 7.42', GARAGE =7.63'. AS THIS STRUCTURE IS LOCATED IN
 FLOOD ZONE A7 WITH A BASE FLOOD ELEVATION OF 7', AND
 WEST PALM BEACH HAS A 6" FREEBOARD, THE MINIMUM
 ELEVATION FOR HABITABLE SPACE AND EQUIPMENT IS 7'6".
 ENCLOSURES UNDER THE HABITABLE SPACE OR AREAS USED FOR
 PARKING, STORAGE OR ACCESS CAN BE LESS THAN 7'6" BUT
 THEN MUST HAVE FLOOD RESISTANT CONSTRUCTION, BE
 DESIGNED TO RESIST FLOOD LOADS, AND HAVE FLOOD VENTS
 INSTALLED. IT IS NOT CLEAR FROM THE SURVEY WHETHER THE
 AREA WHICH IS 7.42' WILL NEED TO BE RAISED TO 7.5'.
  
 WHEN RESUBMITTING, PROVIDE A "CONSTRUCTION DRAWINGS"
 PHASE ELEVATION CERTIFICATE. TWO ADDITIONAL ELEVATION
 CERTIFICATES WILL BE REQUIRED; "BUILDING UNDER
 CONSTRUCTION" AND "FINISHED CONSTRUCTION".
  