Plan Review Details - Permit 14120816
Plan Review Stops For Permit 14120816
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-03-27 Cont ID  
Sent By jwitmer Date 2015-03-27 Time 07:29 Rev Time 0.00
Received By jwitmer Date 2015-03-27 Time 07:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-01-09 Cont ID  
Sent By jwitmer Date 2015-01-09 Time 17:30 Rev Time 0.00
Received By jwitmer Date 2015-01-09 Time 16:30 Sent To  
Notes
2015-01-09 17:15:59BUILDING PLAN REVIEW
 PERMIT: 14120816
 ADD: 8100 IBIS BLVD
 CONT: RIGHT ANGLE CONSTRUCTION
 TEL: (561)313-3301
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 1ST REVIEW
 DATE: FRI. JAN. 09/2015
 ACTION: DENIED
  
 1)SHEET C1 OF 1 NOTES 22 & 23 MAKE THIS PLAN APPEAR TO
 BE A STATE APPROVED BUILDING UNDER THE MODULAR BUILDING
 PROGRAM. CONCRETE MODULAR SYSTEMS DOES NOT HAVE THIS
 MODEL LISTED AS STATE APPROVED NOR DOES IT LIST A STATE
 PLAN REVIEW APPROVAL. THE ENGINEER OF RECORD WILL HAVE
 TO SIGN AND DATE EACH PAGE OF HE PLANS AND THE COVER
 SHEET OF CALCULATION WITH INDEX SHEET WILL ALSO NEED TO
 BE SIGNED AND DATED.
  
 61G15-23.002(2) FL. ADMIN. CODE. PLANS SIGNED & SEALED
 BY A PROFESSIONAL ENGINEER SHALL INCLUDE EITHER THE:
 NAME, ADDRESS AND LICENSE NUMBER OF THE ENGINEER OR,
 THE NAME AND LICENSE NUMBER OF THE ENGINEER AND THE
 NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER
 OF THE ENGINEERING BUSINESS THROUGH WHICH THE ENGINEER
 IS PRACTICING (471.025 F.S. AND 471.023 F.S.).
  
 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR INDEX
 SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED AND
 THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE
 PRODUCTION & PREPARATION OF EACH SECTION OF THE
 ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION
 ON THE COVER SHEET OR INDEX.
  
 2) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 ((C) WALL LOUVERS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (F) SKYLIGHTS WILL NEED TO MEET LARGE MISSILE IMPACT
 TESTING.
  
 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 4) 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE,
 THE CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE
 AND DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS,
 FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND
 RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED.
 PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE
 COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE
 SPECIFIC SITE OR A STATEMENT BY AN ARCHITECT OR
 ENGINEER FOR THE SPECIFIC SITE MUST BE SUBMITTED WITH
 THE CONSTRUCTION DOCUMENTS.
  
 5) STRUCTURAL CALCULATIONS FOR B1798 SHOW V 140 MPH, IS
 THIS VULT OR VASD? THE PRESSURES WILL VARY GREATLY.IT
 APPEARS THE BUILDING CATEGORY IS DESIGNED AS A II WHICH
 WOULD REFLECT A 140 MPH VASD, PLEASE VERIFY ON PLANS.
  
 6) SKYLIGHT DETAIL SHEET D1 OF 1 NEEDS TO BE UPDATED IN
 DESIGN TO THE 2010 FBC-B ASCE 7-10.
  
 7) SHEET C1 OF 1 ALSO INDICATES A SINGLE WATER FOUNTAIN
 PLEASE SHOW CONFORMANCE WITH 2010 FBC-ACCESSIBILITY
 211.2 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING
 FOUNTAINS SHALL BE PROVIDED. ONE DRINKING FOUNTAIN
 SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH 602.7.
  
 8) NO SOILS REPORT WAS SUBMITTED SHOWING HOW THE
 MINIMUM SAFE BEARING VALUE OF 2000 PSF WILL BE
 ACHIEVED. 2010 FBC-B 1803.5.2.
  
 9) SHEET S1 NOTE 2 INDICATES SEE SHEET 3 FOR
 FOUNDATION. SHEET 3 INDICATES FLOOR SLAB DESIGN IS
 BASED ON A FOUNDATION SYSTEM (PROVIDED BY OTHERS), NO
 FOUNDATION DESIGN WAS PROVIDED. 2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION, MINIMUM PLAN REVIEW CRITERIA FOR
 COMMERCIAL BUILDINGS 107.3.5.1.1 (8) FOUNDATIONS .
  
 10) 2010 FBC-B 1809.4 DEPTH AND WIDTH OF FOOTINGS. THE
 MINIMUM DEPTH OF FOOTINGS BELOW THE UNDISTURBED GROUND
 SURFACE SHALL BE 12 INCHES (305 MM). WHERE APPLICABLE,
 THE REQUIREMENTS OF SECTION 1809.5 SHALL ALSO BE
 SATISFIED. THE MINIMUM WIDTH OF FOOTINGS SHALL BE 12
 INCHES (305 MM).
  
 11) PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B 1816.1
 TERMITE PROTECTION.
  
 12) THE PLANS FAIL TO PROVIDE HOW THE BUILDING IS
 DESIGNED TO TRANSFER THE LOADS OF UPLIFT, LATERAL
 LOADS, FROM SLIDDING, MISSING TIE IN TO THE FOUNDATION,
 MAIN WIND FORCE RESISTING SYSTEM. 1609.6.4 DESIGN
 PROCEDURE. THE MWFRS AND THE COMPONENTS AND CLADDING OF
 EVERY BUILDING OR OTHER STRUCTURE SHALL BE DESIGNED FOR
 THE PRESSURES CALCULATED USING EQUATION 16-34.
  
 13) 1503.7 PROTECTION AGAINST DECAY AND TERMITES.
 CONDENSATE LINES AND ROOF DOWNSPOUTS SHALL DISCHARGE AT
 LEAST 1 FOOT (305 MM) AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR
 SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON
 ALL BUILDINGS WITH EAVES OF LESS THAN 6 INCHES (152 MM)
 HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON
 A ROOF ABOVE ANOTHER ROOF.
  
 14) PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B 1203.4.1
 VENTILATION AREA REQUIRED. THE MINIMUM OPENABLE AREA TO
 THE OUTDOORS SHALL BE 4 PERCENT OF THE FLOOR AREA BEING
 VENTILATED.
  
 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-03-31 Cont ID  
Sent By rlecky Date 2015-03-31 Time 11:31 Rev Time 0.00
Received By rlecky Date 2015-03-31 Time 11:31 Sent To  
Notes
2015-03-31 11:32:57SEE ELECTRIC PERMIT #15020067 FOR FEEDER INFORMATION

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-03-26 Cont ID  
Sent By rlecky Date 2015-03-26 Time 14:20 Rev Time 0.00
Received By rlecky Date 2015-03-26 Time 14:15 Sent To  
Notes
2015-03-26 14:20:1614120816
 8100 IBIS BLVD
 MODULAR RESTROOMS
  
 NOTE THAT THESE COMMENTS ARE THE SAME BECAUSE THE
 RESUBMITTAL DID NOT INCLUDE A RESPONSE TO THE ORGINAL
 ELECTRIC COMMENTS.
  
 PROVIDE AN ELECTRIC PERMIT WITH A SITE PLAN SHOWING THE
 LOCATION OF ELECTRICAL SERVICE AND SERVICE FEEDERS. NEC
 215.5
  
 PROVIDE AN ELECTRICAL PLAN WITH THE RISER, PANEL BOARD,
 FAULT CURRENT RATING, ETC?. NEC 215.5
  
 SHOW ALL REQUIRED ACCESS AND SAFE WORKING CLEARANCES
 FOR THE ELECTRICAL SERVICE, MAIN DISCONNECTS AND PANEL
 BOARDS. NEC 110.26
  
 INCREASE THE VALUE OF CONSTRUCTION TO INCLUDE THE
 ELECTRICAL SYSTEM.
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS REVIEW
 561-373-3701
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-01-08 Cont ID  
Sent By rlecky Date 2015-01-08 Time 11:14 Rev Time 0.00
Received By rlecky Date 2015-01-08 Time 11:14 Sent To  
Notes
2015-01-08 11:17:0114120816
 8100 IBIS BLVD
 MODULAR RESTROOMS
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 REVIEW COMMENTS.
  
 PROVIDE AN ELECTRIC PERMIT WITH A SITE PLAN SHOWING THE
 LOCATION OF ELECTRICAL SERVICE AND SERVICE FEEDERS. NEC
 215.5
  
 PROVIDE AN ELECTRICAL PLAN WITH THE RISER, PANEL BOARD,
 FAULT CURRENT RATING, ETC?. NEC 215.5
  
 SHOW ALL REQUIRED ACCESS AND SAFE WORKING CLEARANCES
 FOR THE ELECTRICAL SERVICE, MAIN DISCONNECTS AND PANEL
 BOARDS. NEC 110.26
  
 INCREASE THE VALUE OF CONSTRUCTION TO INCLUDE THE
 ELECTRICAL SYSTEM.
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS REVIEW
 561-373-3701
 [email protected]
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-12-31 Cont ID  
Sent By pleduc Date 2014-12-31 Time   Rev Time 0.00
Received By pleduc Date 2014-12-31 Time 13:49 Sent To  
Notes
2014-12-31 14:52:58THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PROVIDE A FIRE EXTINGUISHER; 2A:10BC MINIMUM.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-04-11 Cont ID  
Sent By tklarge Date 2015-04-11 Time 02:41 Rev Time 0.00
Received By tklarge Date 2015-04-11 Time 01:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-03-27 Cont ID  
Sent By   Date 2015-03-27 Time   Rev Time 0.00
Received By mmanhong Date 2015-03-26 Time 14:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-01-13 Cont ID  
Sent By ajones Date 2015-01-13 Time 10:40 Rev Time 0.00
Received By ajones Date 2014-12-24 Time 11:20 Sent To  
Notes
2014-12-29 11:14:02SENT TO C13 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2015-04-14 Cont ID  
Sent By ndaniels Date 2015-04-14 Time 16:42 Rev Time 0.00
Received By ndaniels Date   Time   Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2015-01-09 Time   Rev Time 0.00
Received By jwitmer Date 2015-01-09 Time 16:31 Sent To  
Notes
2015-01-09 16:30:57BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2015-01-09 Cont ID  
Sent By jwitmer Date 2015-01-09 Time 17:23 Rev Time 0.00
Received By jwitmer Date 2015-01-09 Time 17:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-04-11 Cont ID  
Sent By tklarge Date 2015-04-11 Time 02:41 Rev Time 0.00
Received By tklarge Date 2015-04-11 Time 01:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-03-27 Cont ID  
Sent By tklarge Date 2015-03-27 Time 05:51 Rev Time 0.00
Received By tklarge Date 2015-03-27 Time 05:18 Sent To  
Notes
2015-03-27 05:30:021) SHOW ON THE SITE PLAN HOW WATER AND SEWER WILL BE
 BROUGHT TO THIS BUILDING. SHOW THE WATER AND SEWER
 LINES ON THE SITE PLAN AND SHOW THE SIZES OF EACH LINE.
 WPB AMEND. TO 2010 FBC SEC.107.2.1.2ND REQUEST.
 2) A MINIMUM OF A DOUBLE CHECK VALVE BACKFLOW PREVENTER
 SHALL BE INSTALLED ON THE WATER SERVICE AT THE METER IN
 ACCORDANCE WITH THE CWPB CROSS CONNECTION MANUAL. SHOW
 THE LOCATION OF THE BFP DEVICE & METER ON THE SITE
 PLAN. 2ND REQUEST.
 3) A MINIMUM OF TWO DRINKING FOUNTAINS ARE REQUIRED PER
 THE 2010 FL. ACCESSIBILITY CODE SEC.211.2. ONLY ONE
 DRINKING FOUNTAIN IS SHOWN. 2ND REQUEST.
 4) THE DESCRIPTION OF WORK ON THE PLUMBING APPLICATION
 REFERS TO A MINI LIFT STATION. SUBMIT MANUFACTURER'S
 SPECS ON THE LIFT STATION ( PUMPS & BASIN ) AND A
 PIPING DIAGRAM FOR ALL PIPING. SHOW THE LOCATION OF THE
 LIFT STATION ON THE SITE PLAN, WPB AMEND. TO 2010 FBC
 SEC.107.2.1. SUMP, EJECTOR AND PIPING SHALL COMPLY W/
 2010 FPC SEC. 712.1, 712.2, 712.3.2, 712.3.5, 712.4.2,
 916.5 & 916.5.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-01-04 Cont ID  
Sent By tklarge Date 2015-01-04 Time 06:58 Rev Time 0.00
Received By tklarge Date 2015-01-04 Time 06:46 Sent To  
Notes
2015-01-04 06:02:101) SHOW ON THE SITE PLAN HOW SEWER AND WATER WILL BE
 BROUGHT TO THIS BUILDING. WPB AMENDMENTS TO 2010 FBC
 SEC.107.2.1.
 2) SUBMIT DOCUMENTATTION THAT THE SUBMITTED PLANS HAVE
 BEEN REVIEWED AND APPROVED BY A AN AGENCY AUTHORIZED TO
 PERFORM PLAN REVIEW IN ACCORDANCE WITH FL. ADMIN. CODE
 RULE 9B-1, FL. STATUTE 553.37 & THE 2010 FBC
 SEC.428.4.2 AND THAT THEY COMPLY WITH THE 2010 FBC PER
 THE 2010 FBC SEC.428.4.1.
 3) A MINIMUM OF A DOUBLE CHECK VALVE BACKFLOW
 PREVENTION DEVICE SHALL BE INSTALLED ON THE WATER
 SERVICE NEAR THE SOURCE PER THE CWPB CROSS CONNECTION
 ORDINANCE.
 4) A MINIMUM OF TWO DRINKING FOUNTAINS ARE REQUIRED PER
 THE 2010 FL. ACCESSIBILITY CODE SEC. 211.2.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2015-01-13 Cont ID  
Sent By avann Date 2015-01-13 Time 10:39 Rev Time 0.00
Received By ajones Date 2015-01-13 Time 10:39 Sent To  
Notes
***NONE***