Plan Review Details - Permit 14120688
Plan Review Stops For Permit 14120688
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2015-03-12 Cont ID  
Sent By jwitmer Date 2015-03-12 Time 14:17 Rev Time 0.00
Received By jwitmer Date 2015-03-10 Time 06:01 Sent To  
Notes
2015-03-10 06:20:26BUILDING PLAN REVIEW
 PERMIT: 14120688/ CLUBHOUSE
 ADD: 820 GRANT ST.
 CONT: T. B. D. /AYALA MANUEL
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2ND 1ST REVIEW
 DATE: TUES. MARCH 10/ 2015
 ACTION: APPROVED
  
 1) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2
 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION,
 DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF
 THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE
 APPLICATION AND THAT ARE TO BE SUBMITTED TO THE
 BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL
 OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF
 THE BUILDING OFFICIAL. THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE
 DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR
 REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED
 SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL
 REVIEW THEM AND FORWARD THEM TO THE
 BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND
 FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE
 BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE
 INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN APPROVED BY THE BUILDING OFFICIAL.
  
 COMPONENTS & CLADDING
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (E) SHUTTERS
 (F) SKYLIGHTS
 (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C
 STANDS
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-01-12 Cont ID  
Sent By jwitmer Date 2015-01-12 Time 16:58 Rev Time 0.00
Received By jwitmer Date 2015-01-12 Time 15:23 Sent To  
Notes
2015-01-12 16:13:18BUILDING PLAN REVIEW
 PERMIT: 14120688/ CLUBHOUSE
 ADD: 820 GRANT ST.
 CONT: T. B. D. /AYALA MANUEL
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JAN. 12/ 2015
 ACTION: DENIED
  
 1) SHEET S2 INDICATES THE EXISTANCE OF A SOILS REPORT
 BY ARDAMIN & ASSOC. FILE# 14-1657 MAY 23/ 14TH. PLEASE
 SUBMIT 3 ORIGINAL SIGNED & SEALED REPORTS.
  
  
 2) PAGE 007 FIRST FLOOR LIFE SAFETY: GREAT ROOM 1841
 SQ. FT./ 15= 122 THE DESIGNER HAS DROPPED THE FRACTION
 OF AN OCCUPANT, YOU ROUND UP NOT DOWN TO THE NEXT WHOLE
 NUMBER. FBC-B 1004.1. ALSO SEE BOAF INFORMAL
 INTERPRETATION 5479. THIS HAS ALSO OCCURED IN THE
 LOUNGE 177/15= 12.
  
 3) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2
 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION,
 DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF
 THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE
 APPLICATION AND THAT ARE TO BE SUBMITTED TO THE
 BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL
 OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF
 THE BUILDING OFFICIAL. THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE
 DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR
 REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED
 SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL
 REVIEW THEM AND FORWARD THEM TO THE
 BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND
 FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE
 BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE
 INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN APPROVED BY THE BUILDING OFFICIAL.
  
 3A) NOA 12-0320.07 SUNSHINE 2000 SERIES SINGLE HUNG,
 LMI PLEASE CIRCLE THE UNITS HEIGHT, WIDTH, PRESSURES &
 ANCHORAGE.
  
 3B) NOA 13-0122.05 SUNSHINE 8000 SERIES STOREFRONT, LMI
 PLEASE CIRCLE THE UNITS HEIGHT, WIDTH, PRESSURES &
 ANCHORAGE.
  
 3C) NOA 11-1216.02 SUNSHINE MULLION CIRCLE WIDTH, SPAN,
 MULLION SIZE PRESSURES AND TYPE OF ANCHORS.
  
 3D) NOA 14-0109.06 SUNSHINE ALUMINUM, OUTSWING FRENCH
 DOORS NOTE FLUSHBOLTS WILL NEED TO WORK FROM A WHEEL
 CHAIR POSITION, PLEASE CIRCLE THE UNITS HEIGHT, WIDTH,
 PRESSURES & ANCHORAGE.
  
 3E) FL. 14237-R1 FLEMING BARON CIRCLE IF SINGLE OR
 PAIR, INSWEING OR OUT, TYPE OF LATCH ANCHORAGE AND
 ASSOCIATED PRESSURES.
  
 3F) NOA 13-1104.12 GAF TIMBERLINE ULTRA HD SHINGLES .
  
 3G) PLEASE PROVIDE THE WINDOW AND DOOR SHGC OF 0.5
 FBC-ENERGY 402.3.
  
 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 5) ROOF VENTILATION PAGE 010, A-1.03 THE PLANS INDICATE
 THE USE OF SOFFIT VENTILATION BUT DO NOT INDICATE
 COMPLIANCE WITH FBC-B 1203.2 50 PERCENT OF THE REQUIRED
 VENTILATING AREA PROVIDED BY VENTILATORS LOCATED IN THE
 UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3
 FEET (914 MM) ABOVE EAVE OR CORNICE VENTS WITH THE
 BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR
 CORNICE VENTS. IF THE CUPALO IS AN ACTIVE VENTILATING
 CUPALO PLEASE PROVIDE THE SQ. FT. OF VENTING AND HOW
 THIS UNIT WILL BE FRAMED AND TIED INTO THE ROOF
 FRAMING.
  
 6) PAGE 011/ A-1.04 THERE ARE (3) CODE SECTIONS SECTION
 1817 HIGH VELOCITY HURRICANE- EXCAVATIONS, SECTION 1818
 HIGH VELOCITY HURRICANE ZONES BEARING CAPACITY OF
 SOILS, & SECTION 2326 HIGH VELOCITY HURRICANE ZONES-
 REOTECTION OF WOOD, THESE CODE SECTION WILL NEED TO BE
 REMOVED FROM THE PLANS, THESE CODE SECIONS ARE FOR
 BROWARD AND MIAMI-DADE COUNTY ONLY. PALM BEACH COUNTY
 IS NOT IN THE HVHZ BUT IN A WIND BORN DEBRIS REGION.
  
 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 8). A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-04-25 Cont ID  
Sent By dhayes Date 2015-04-25 Time 16:08 Rev Time 0.00
Received By dhayes Date 2015-04-25 Time 15:40 Sent To  
Notes
2015-04-25 15:59:29THIS ELECTRICAL DESIGN SUBMITTED IS APPROVED FOR
 PERMIT. PLEASE PROVIDE AN ELECTRICAL PERMIT APPLICATION
 FROM A REGISTERED ELECTRICAL CONTRACTOR PRIOR TO
 COMMENCEMENT OF THE ELECTRICAL INSTALLATION.
  
 THE FIRE ALARM SYSTEM MODIFICATION HAS NOT BEEN
 REVIEWED OR APPROVED FOR PERMIT AT THIS TIME. PLEASE
 PROVIDE A SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY
 MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS
 FOR ALL LOW VOLTAGE SPECIALTY SYSTEMS SUCH AS BUT NOT
 LIMITED TO THE FOLLOWING:
  
 FIRE ALARM, SITE LIGHTING, GENERATORS.
 DATA/COMMUNICATION, ACCESS CONTROL SYSTEM, SECURITY,
 CCTV, AND/OR AUDIO/VIDEO IF PROPOSED FOR FUTURE USE.
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-03-11 Cont ID  
Sent By dhayes Date 2015-03-11 Time 10:16 Rev Time 0.00
Received By dhayes Date 2015-03-11 Time 09:24 Sent To  
Notes
2015-03-11 10:15:313/11/2015
 PROJECT: DUNBAR BLDG 3 CLUBHOUSE
 PERMIT#: 14120688
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 2ND ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 SHEET E3.1
 1) REVISE THE FEEDER SCHEDULE KEY NOTES. THE 11/4"
 CONDUIT INDICATED IN KEY NOTES 2 AND 3 IS NOT ADAQUATE
 TO SUPPORT THE 4, 4/0 CONDUCTORS. NEC ANNEX C
 2) PROVIDE A FAULT CURRENT STUDY TO DETERMINE THE
 VAULUE OF THE FAULT CURRENT AVAILABLE AT THE EQUIPMENT.
 I DENTIFY THE FAULT CURRENT RATING OF THE EQUIPMENT
 PROPOSED TO VERIFY IF WILL BE EQUIPPED WITH A 3) FAULT
 CURRENT RATING THAT IS SUFFICIENT AT NOMINAL CIRCUIT
 VOLTAGE FOR THE CURRENT THAT MUST BE INTERRUPTED. NEC
 110.9
 4) PROVIDE SAFETY LABELING FOR ARC FLASH PROTECTION FOR
 THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. NEC
 110.16.
 5) VERIFY SUFFICIENT ACCESS AND WORKING SPACE IS
 PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT
 TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF
 SUCH EQUIPMENT. NEC110.26
 6) REVISE SIZE OF GROUNDING ELECTRODE CONDUCTOR FOR
 CONSISTANCY. THE RISER DIAGRAM INDICATES A #3 GEC BUT
 THE GROUNDING DETAIL AND NOTES ON SHEET E5.1 INDICATE
 THE USE OF A #3/0 CU GEC. FBC107
  
 SHEET E4.1
 ADD NOTE 4 TO CIRCUIT #31 FOR EXTERIOR LIGHTING
  
 SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY
 MANUFACTURERS EQUIPMENT SUBMITTALS, WIND LOAD
 ENGINEERING ARE REQUIRED FOR SITE LIGHTING.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-01-26 Cont ID  
Sent By dhayes Date 2015-01-26 Time 16:56 Rev Time 0.00
Received By dhayes Date 2015-01-26 Time 16:28 Sent To  
Notes
2015-01-26 16:56:391/26/2015
 PROJECT: DUBAR SENIOR COMPLEX CLUBHOUSE
 PERMIT#: 14120688
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) SHEET E1.1
 A.) PROVISIONS SHALL BE MADE TO PROVIDE EMERGENCY
 ILLUMINATION AND EXIT LIGHTING FOR SAFE MEANS OF EGRESS
 TO A PUBLIC RIGHT OF WAY. NFPA 101, 7.10.1.5.1, NEC
 700.16, NEC 700.12
 B.) CHANGE THE MOTION SENSOR SWITCH IN THE ELECTRICAL
 ROOM TO A STANDARD TOGGLE SWITCH. FBC ENERGY 505.2.2
 EX(4) SPACES WHERE AN AUTOMATIC SHUTOFF WOULD ENDANGER
 OCCUPANT SAFETY OR SECURITY.
 C.) IDENTIFY THE OUTLET FOR THE DRINKING FOUNTAIN AS
 GFCI PROTECTED. ELECTRIC DRINKING FOUNTAINS SHALL BE
 PROTECTED WITH GROUND FAULT CIRCUIT INTERRUPTER
 PROTECTION. NEC 422.52
 D.) PROVISIONS SHALL BE MADE FOR THE REQUIRED WORKING
 CLEARANCE, DISCONNECTING MEANS AND ACCESS TO ELECTRICAL
 EQUIPMENT FOR THE A/C AHU IN THE ATTIC SPACE. SEE NEC
 110.33(B), NEC 440.11, FBC-M 306.3.2
 E.) PROVIDE A SWITCHED LIGHT AT THE ATTIC ACCESS FOR
 ILLUMINATION AT ELECTRICAL EQUIPMENT. SEE NEC 210.70(3)
  
 2) SHEET E3.1
 THE PROPOSED ELECTRICAL RISER DIAGRAM MAKES REFFRENCE
 TO A GROUNDING ELECTRODE DETAIL ON SHEET E8.3 HOWEVER
 THERE IS NO SHEET E8.3 IN THIS SUBMITTAL PACKAGE.
 PLEASE CLARIFY. WPB AMENDMENTS TO FBC 107.2
  
 3) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY
 MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS
 ARE REQUIRED FOR SITE LIGHTING, GENERATORS. HOOD
 EXHAUST, FIRE ALARM, ACCESS CONTROL SYSTEM, SECURITY,
 CCTV, AUDIO/VIDEO, NETWORK, DATA, AND, COMMUNICATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2015-03-11 Cont ID  
Sent By cranford Date 2015-03-11 Time 11:47 Rev Time 0.00
Received By cranford Date 2015-03-11 Time 11:41 Sent To  
Notes
2015-03-11 11:46:52ALSO BEING REVIEWED UNDER ENGINEERING APPLICATION
 E14120027.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2015-01-02 Cont ID  
Sent By cranford Date 2015-01-02 Time 15:35 Rev Time 0.00
Received By cranford Date 2015-01-02 Time 15:33 Sent To  
Notes
2015-01-02 15:35:34PLEASE SUBMIT APPLICATIONS FOR A DEVELOPMENT PERMIT
 FROM THE ENGINEERING DEPARTMENT. APPLICATION FORMS CAN
 BE FOUND AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
 (SECTIONS 2-421 AND 78-432, CODE OF ORDINANCES)
  
 ALSO SEE COMMENTS UNDER APP 14120680

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2015-03-04 Cont ID  
Sent By wjolin Date 2015-03-04 Time 15:14 Rev Time 0.00
Received By wjolin Date 2015-03-04 Time 14:28 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-02-06 Cont ID  
Sent By wjolin Date 2015-02-06 Time 16:14 Rev Time 0.00
Received By wjolin Date 2015-02-06 Time 15:04 Sent To  
Notes
2015-02-06 15:39:27820 GRANT STREET - CLUBHOUSE
 PERMIT #14120688
 REVIEW COMMENTS - FIRE DEPARTMENT
  
  
 GENERAL: STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE LETTER R DESIGNATION PER
 FLORIDA STATUTE 633.027 AND FLORIDA ADMINISTRATIVE CODE
 69A-60.0081.
  
 GENERAL: EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED
 SEATS SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED
 IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE
 ROOM. SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF
 OCCUPANTS PERMITTED FOR EACH ROOM.
  
 SHEET A-0.01: THE TURNING RADIUS APPEARS TO BE TOO
 SMALL TO ACCOMODATE A 47'-0" LONG LADDER TRUCK FOR THE
 PARKING LOT ACCESS ROAD DIRECTLY SOUTH OF THE CLUBHOUSE
 (NOT THE DROP-OFF AREA).
  
 SHEET A-0.04: ANOTHER EXIT SIGN IS NEEDED OUTSIDE THE
 LOUNGE, OTHERWISE THE COMMON PATH OF TRAVEL EXCEEDS 20
 FOR AN AREA SERVING MORE THAN 50 PERSONS. PANIC
 HARDWARE WILL BE NEEDED ON THE LOUNGE DOOR.
  
 SHEET A-0.04: INDICATE THE LOCATION/TRAVEL TO THE
 PUBLIC WAY FOR THE NORTH EXIT.
  
 SHEET A-0.04: UTILITY (LAUNDRY) ROOMS SHALL BE PROVIDED
 WITH A 1-HOUR FIRE SEPARATION AND AUTOMATIC SPRINKLER
 PROTECTION PER SECTION 12.3.2.1.2(2)(A) OF NFPA 101.
  
 SHEET A-1.01: PROVIDE A PROPOSED FURNITURE LAYOUT TO
 SUPPORT THE USE OF THE 15 SQ.FT. PER PERSON OCCUPANT
 LOAD FACTOR.
  
 SHEET A-6.01: FOR ASSEMBLY OCCUPANCIES WITH AN OCCUPANT
 LOAD OF 100 OR MORE PERSONS (50 PERSONS PER THE FLORIDA
 BUILDING CODE), PANIC HARDWARE SHALL BE PROVIDED ON
 DOORS TO RELEASE THE LOCK/LATCH. NO OTHER LOCKS OR
 LATCHES ARE PERMITTED THAT WOULD NOT BE RELEASED BY THE
 PANIC HARDWARE. AS A SUBSTITUTE FOR PANIC HARDWARE, THE
 MAIN ENTRANCE IS PERMITTED TO HAVE AN INTERIOR KEYED
 DOOR LOCK (AND NO LATCH) WITH A READILY VISIBLE SIGN
 STATING THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING
 IS OCCUPIED. SIGN LETTERS SHALL BE AT LEAST 1 INCH IN
 HEIGHT. KEYED LOCK TO BE EQUIPPED WITH AN "OPEN/LOCKED"
 INDICATOR WINDOW (SUCH AS ADAMS RITE 4089 OR SIMILAR).
 A THUMB TURN STYLE LOCK IS NOT PERMITTED TO BE
 SUBSTITUTED FOR A KEYED LOCK.
  
 SHEET E-1.1: COULD NOT LOCATE ANY EXIT SIGNS OR
 EMERGENCY LIGHTS.
  
 SHEET FA0.1: FIRE ALARM SYSTEM SHALL BE FULLY
 ADDRESSABLE. A CERTIFICATE OF COMPLETION AND A THIRD
 PARTY MONITORING/VERIFICATION (UL OR ETL) CERTIFICATE
 SHALL BE PROVIDED AT TIME OF FINAL FIRE ALARM
 INSPECTION.
  
 SHEET FA1.1: INSUFFICIENT NOTIFICATION APPLIANCES
 PROVIDED. ADDITIONALLY, PROVIDE AN EXTERIOR
 NOTIFICATION DEVICE TO ALERT EMERGENCY RESPONDERS
 PROMPTLY.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-05-12 Cont ID  
Sent By skennedy Date 2015-05-12 Time 09:48 Rev Time 0.00
Received By skennedy Date 2015-04-03 Time 08:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-02 Cont ID  
Sent By lmarchan Date 2015-04-02 Time 13:17 Rev Time 0.00
Received By lmarchan Date 2015-02-26 Time 11:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-02-10 Cont ID  
Sent By cpuell Date 2015-02-10 Time 13:42 Rev Time 0.00
Received By cpuell Date 2014-12-22 Time 19:39 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2015-09-08 Cont ID  
Sent By skennedy Date 2015-09-08 Time 16:09 Rev Time 0.00
Received By skennedy Date 2015-09-08 Time 16:09 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status N Date 2015-04-27 Cont ID  
Sent By lmarchan Date 2015-04-27 Time 08:55 Rev Time 0.00
Received By lmarchan Date 2015-04-27 Time 08:55 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-03-10 Cont ID  
Sent By   Date 2015-03-10 Time   Rev Time 0.00
Received By   Date 2015-03-10 Time   Sent To  
Notes
2015-03-10 06:04:18BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-01-12 Cont ID  
Sent By jwitmer Date 2015-01-12 Time 16:37 Rev Time 0.00
Received By jwitmer Date 2015-01-12 Time 16:36 Sent To  
Notes
2015-01-12 16:37:07BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-03-19 Cont ID  
Sent By hmoser Date 2015-03-19 Time 11:15 Rev Time 0.00
Received By hmoser Date 2015-03-19 Time 10:18 Sent To  
Notes
2015-03-19 11:15:52PASS
 REFER TO SECTION 606.3 INSTALLATION.
 2010 FBC (M) ACCESS SHALL BE PROVIDED TO SMOKE
 DETECTORS FOR INSPECTION AND MAINTENANCE.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-01-20 Cont ID  
Sent By hmoser Date 2015-01-20 Time 13:14 Rev Time 0.00
Received By hmoser Date 2015-01-20 Time 10:08 Sent To  
Notes
2015-01-20 13:13:58PLAN DENIED
 1) PROVIDE DUCT SIZE ON ALL SUPPLY
 AND RETURN AIR DUCT. PER SECTION
 107 FBC 2010.
 2) REFER TO SECTION 602.2.1 MATERIALS WITHIN
 PLENUM'S 2010 FBC (M) INCLUDING DOORS.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2015-03-24 Cont ID  
Sent By tklarge Date 2015-03-24 Time 09:25 Rev Time 0.00
Received By tklarge Date 2015-03-24 Time 07:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-01-03 Cont ID  
Sent By tklarge Date 2015-01-03 Time 09:09 Rev Time 0.00
Received By tklarge Date 2015-01-03 Time 04:52 Sent To  
Notes
2015-01-03 08:29:461) SHT.A-1.04 REFERS TO THE USE OF MOISTURE RESISTANT
 GYPSUM BOARD IN WET AREAS. PLEASE REFER TO FBC SEC.
 2509.3 FOR LIMITATIONS.
 2) SHT.A-5.00 - THE TOILET PAPER DISPENSER SHALL BE
 LOCATED A MIN. OF 7 INCHES AND A MAX. OF 9 INCHES FROM
 THE FRONT OF THE WATER CLOSET MEASURED TO THE
 CENTERLINE OF THE DISPENSER PER THE FL. ACCESSIBILITY
 CODE SEC. 604.7.
 3) SHT.A-5.00 - GRAB BARS SHALL BE MEASURED TO THE TOP
 OF THE GRIPPING SURFACE FROM THE FINISH FLOOR NOT TO
 THE CENTERLINE AS SHOWN. 2010 FAC SEC.609.4.
 4) SHT. A-5.00 - THERE ARE REFERENCES TO CODE SECTIONS
 AND FIGURE NUMBERS OF CHAPTER 11 OF THE 2010 FAC. THESE
 CODE SECTIONS OR FIGURE NUMBERS DO NOT EXIIST IN THE
 2010 FBC. PLEASE REVISE TO REFLECT THE CORRECT CODE
 SECTIONS AND FIGURE NUMBERS. WPB AMEND. TO 2010 FBC
 SEC. 107.2.1.
 5) SHT.A-5.01 - BATH PLAN A - THE PLAN VIEW SHOWS THE
 MEASUREMENT TO THE CENTERLINE OF THE WATER CLOSET AS 18
 INCHES MINIMUM. THE DISTANCE SHALL BE 16-18 INCHES FROM
 THE SIDE WALL PER THE 2010 FBC SEC.604.2.
 6) SHT.A-5.01 - BATH PLANS A,B & C - ELEVATIONS A & B
 SEEM TO BE IN CONFLICT REGARDING THE HEIGHT OF THE
 WATER CLOSET SEAT ABOVE THE FINISH FLOOR. ELEVATION A
 SHOWS THE HEIGHT MEASURED TO THE TOP OF THE SEAT WHICH
 IS CORRECT BUT ELEVATION B APPEARS TO HAVE THE
 MEASUREMENT TO THE TOP OF THE TOILET BOWL. COMPLY WITH
 THE 2010 FAC SEC.604.4.
 7) SHT. A-5.01 - THE GRAB BARS IN THE ELEVATION DETAILS
 SHALL BE MEASURED FROM THE FINISH FLOOR TO THE TOP OF
 THE GRIPPING SURFACE PER SEC. 609.4 OF THE 2010 FAC.
 8) SHT.A-5.01 - THE ACCESSORY SCHEDULE LISTS AN ADA
 SHOWERHEAD BUT THE LOCATION IS NOT SHOWN ON THE PLAN.
 CLARIFY.
 9) SHOW THE LOCATION OF THE SHOWER CONTROLS IN BATH
 PLAN. COMPLY WITH 2010 FAC SEC.608.5.2 & 608.6.
 10) SHT. P-1.1 - SHOWS A BACKWATER VALVE ON THE
 SANITARY LINE. BACKWATER VALVES SHALL ONLY BE INSTALLED
 WHEN THE FLOOD LEVEL RIM OF PLUMBING FIXTURES ARE BELOW
 THE ELEVATION OF THE MANHOLE COVER OF THE NEXT
 UPSTREAMMANHOLE IN THE PUBLIC SEWER PER FPC SEC. 715.1.
 REMOVE THE BACKWATER VALVE.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2015-05-08 Cont ID  
Sent By skennedy Date 2015-05-08 Time 16:34 Rev Time 0.00
Received By skennedy Date 2015-05-08 Time 16:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2015-05-07 Cont ID  
Sent By skennedy Date 2015-05-07 Time 09:47 Rev Time 0.00
Received By skennedy Date 2015-05-07 Time 09:47 Sent To  
Notes
2015-05-07 09:50:061ST REVIEW: FBC 2010
  
 PROVIDE SIGNATURE REPORTS FOR EACH DESIGNER. IF NO
 LONGER PRINTABLY AVAILABLE FROM FDOT PEDDS PROGRAM,
 PROVIDE A SCREEN SHOTS FROM THE PROGRAM TO AUTHINTICATE
 THE SIGNATURE DOCUMENTS PROVIDED AS TIED TO THE DESIGN.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2015-02-27 Cont ID  
Sent By cpuell Date 2015-02-27 Time 16:39 Rev Time 0.00
Received By cpuell Date 2015-02-27 Time 16:39 Sent To  
Notes
2015-02-27 16:44:41SOIL TEST REPORT SUBMITTED IN PAPER SIGNED & SEALED
 UPLOADED DOCUMENTS TO BE REVIEWED. CP

Review Stop Z ZONING
Rev No 3 Status P Date 2015-04-09 Cont ID  
Sent By ajones Date 2015-04-09 Time 17:53 Rev Time 0.00
Received By ajones Date 2015-04-09 Time 17:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2015-04-02 Cont ID  
Sent By ajonesva Date 2015-04-02 Time 12:43 Rev Time 0.00
Received By ajones Date 2015-04-02 Time 12:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-01-13 Cont ID  
Sent By avann Date 2015-01-13 Time 14:53 Rev Time 0.00
Received By ajones Date 2015-01-13 Time 14:53 Sent To  
Notes
2015-01-13 14:58:141/13/15- FAILED. 1. SITE PLAN DOES NOT MATCH APPROVED
 SITE PLAN.
 2. NEED TO UNDERSTAND THE ARCHITECTURE OF THE BUILDING.
 APPEARS TO BE DIFFERENT FROM THE CONCEPTUAL DRAWINGS
 THE COMMISSION SAW AND APPROVED.
  
  
 ANGELLA VANN. AICP
 PLANNING AND ZONING ADMINISTRATOR
  
 561-822-1441
 [email protected]
  