| Plan Review Stops For Permit 14120688 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-03-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-03-12 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-03-10 |
Time |
06:01 |
Sent To |
|
|
| Notes |
| 2015-03-10 06:20:26 | BUILDING PLAN REVIEW | | | PERMIT: 14120688/ CLUBHOUSE | | | ADD: 820 GRANT ST. | | | CONT: T. B. D. /AYALA MANUEL | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2ND 1ST REVIEW | | | DATE: TUES. MARCH 10/ 2015 | | | ACTION: APPROVED | | | | | | 1) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2 | | | DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, | | | DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF | | | THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE | | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | | REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED | | | SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL | | | REVIEW THEM AND FORWARD THEM TO THE | | | BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE | | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND | | | FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE | | | BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE | | | INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN APPROVED BY THE BUILDING OFFICIAL. | | | | | | COMPONENTS & CLADDING | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-01-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-12 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-01-12 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2015-01-12 16:13:18 | BUILDING PLAN REVIEW | | | PERMIT: 14120688/ CLUBHOUSE | | | ADD: 820 GRANT ST. | | | CONT: T. B. D. /AYALA MANUEL | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: MON. JAN. 12/ 2015 | | | ACTION: DENIED | | | | | | 1) SHEET S2 INDICATES THE EXISTANCE OF A SOILS REPORT | | | BY ARDAMIN & ASSOC. FILE# 14-1657 MAY 23/ 14TH. PLEASE | | | SUBMIT 3 ORIGINAL SIGNED & SEALED REPORTS. | | | | | | | | | 2) PAGE 007 FIRST FLOOR LIFE SAFETY: GREAT ROOM 1841 | | | SQ. FT./ 15= 122 THE DESIGNER HAS DROPPED THE FRACTION | | | OF AN OCCUPANT, YOU ROUND UP NOT DOWN TO THE NEXT WHOLE | | | NUMBER. FBC-B 1004.1. ALSO SEE BOAF INFORMAL | | | INTERPRETATION 5479. THIS HAS ALSO OCCURED IN THE | | | LOUNGE 177/15= 12. | | | | | | 3) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2 | | | DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, | | | DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF | | | THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE | | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | | REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED | | | SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL | | | REVIEW THEM AND FORWARD THEM TO THE | | | BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE | | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND | | | FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE | | | BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE | | | INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN APPROVED BY THE BUILDING OFFICIAL. | | | | | | 3A) NOA 12-0320.07 SUNSHINE 2000 SERIES SINGLE HUNG, | | | LMI PLEASE CIRCLE THE UNITS HEIGHT, WIDTH, PRESSURES & | | | ANCHORAGE. | | | | | | 3B) NOA 13-0122.05 SUNSHINE 8000 SERIES STOREFRONT, LMI | | | PLEASE CIRCLE THE UNITS HEIGHT, WIDTH, PRESSURES & | | | ANCHORAGE. | | | | | | 3C) NOA 11-1216.02 SUNSHINE MULLION CIRCLE WIDTH, SPAN, | | | MULLION SIZE PRESSURES AND TYPE OF ANCHORS. | | | | | | 3D) NOA 14-0109.06 SUNSHINE ALUMINUM, OUTSWING FRENCH | | | DOORS NOTE FLUSHBOLTS WILL NEED TO WORK FROM A WHEEL | | | CHAIR POSITION, PLEASE CIRCLE THE UNITS HEIGHT, WIDTH, | | | PRESSURES & ANCHORAGE. | | | | | | 3E) FL. 14237-R1 FLEMING BARON CIRCLE IF SINGLE OR | | | PAIR, INSWEING OR OUT, TYPE OF LATCH ANCHORAGE AND | | | ASSOCIATED PRESSURES. | | | | | | 3F) NOA 13-1104.12 GAF TIMBERLINE ULTRA HD SHINGLES . | | | | | | 3G) PLEASE PROVIDE THE WINDOW AND DOOR SHGC OF 0.5 | | | FBC-ENERGY 402.3. | | | | | | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 5) ROOF VENTILATION PAGE 010, A-1.03 THE PLANS INDICATE | | | THE USE OF SOFFIT VENTILATION BUT DO NOT INDICATE | | | COMPLIANCE WITH FBC-B 1203.2 50 PERCENT OF THE REQUIRED | | | VENTILATING AREA PROVIDED BY VENTILATORS LOCATED IN THE | | | UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 | | | FEET (914 MM) ABOVE EAVE OR CORNICE VENTS WITH THE | | | BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR | | | CORNICE VENTS. IF THE CUPALO IS AN ACTIVE VENTILATING | | | CUPALO PLEASE PROVIDE THE SQ. FT. OF VENTING AND HOW | | | THIS UNIT WILL BE FRAMED AND TIED INTO THE ROOF | | | FRAMING. | | | | | | 6) PAGE 011/ A-1.04 THERE ARE (3) CODE SECTIONS SECTION | | | 1817 HIGH VELOCITY HURRICANE- EXCAVATIONS, SECTION 1818 | | | HIGH VELOCITY HURRICANE ZONES BEARING CAPACITY OF | | | SOILS, & SECTION 2326 HIGH VELOCITY HURRICANE ZONES- | | | REOTECTION OF WOOD, THESE CODE SECTION WILL NEED TO BE | | | REMOVED FROM THE PLANS, THESE CODE SECIONS ARE FOR | | | BROWARD AND MIAMI-DADE COUNTY ONLY. PALM BEACH COUNTY | | | IS NOT IN THE HVHZ BUT IN A WIND BORN DEBRIS REGION. | | | | | | 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 8). A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-04-25 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-04-25 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-04-25 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2015-04-25 15:59:29 | THIS ELECTRICAL DESIGN SUBMITTED IS APPROVED FOR | | | PERMIT. PLEASE PROVIDE AN ELECTRICAL PERMIT APPLICATION | | | FROM A REGISTERED ELECTRICAL CONTRACTOR PRIOR TO | | | COMMENCEMENT OF THE ELECTRICAL INSTALLATION. | | | | | | THE FIRE ALARM SYSTEM MODIFICATION HAS NOT BEEN | | | REVIEWED OR APPROVED FOR PERMIT AT THIS TIME. PLEASE | | | PROVIDE A SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | FOR ALL LOW VOLTAGE SPECIALTY SYSTEMS SUCH AS BUT NOT | | | LIMITED TO THE FOLLOWING: | | | | | | FIRE ALARM, SITE LIGHTING, GENERATORS. | | | DATA/COMMUNICATION, ACCESS CONTROL SYSTEM, SECURITY, | | | CCTV, AND/OR AUDIO/VIDEO IF PROPOSED FOR FUTURE USE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-03-11 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-03-11 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-03-11 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2015-03-11 10:15:31 | 3/11/2015 | | | PROJECT: DUNBAR BLDG 3 CLUBHOUSE | | | PERMIT#: 14120688 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | SHEET E3.1 | | | 1) REVISE THE FEEDER SCHEDULE KEY NOTES. THE 11/4" | | | CONDUIT INDICATED IN KEY NOTES 2 AND 3 IS NOT ADAQUATE | | | TO SUPPORT THE 4, 4/0 CONDUCTORS. NEC ANNEX C | | | 2) PROVIDE A FAULT CURRENT STUDY TO DETERMINE THE | | | VAULUE OF THE FAULT CURRENT AVAILABLE AT THE EQUIPMENT. | | | I DENTIFY THE FAULT CURRENT RATING OF THE EQUIPMENT | | | PROPOSED TO VERIFY IF WILL BE EQUIPPED WITH A 3) FAULT | | | CURRENT RATING THAT IS SUFFICIENT AT NOMINAL CIRCUIT | | | VOLTAGE FOR THE CURRENT THAT MUST BE INTERRUPTED. NEC | | | 110.9 | | | 4) PROVIDE SAFETY LABELING FOR ARC FLASH PROTECTION FOR | | | THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. NEC | | | 110.16. | | | 5) VERIFY SUFFICIENT ACCESS AND WORKING SPACE IS | | | PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT | | | TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF | | | SUCH EQUIPMENT. NEC110.26 | | | 6) REVISE SIZE OF GROUNDING ELECTRODE CONDUCTOR FOR | | | CONSISTANCY. THE RISER DIAGRAM INDICATES A #3 GEC BUT | | | THE GROUNDING DETAIL AND NOTES ON SHEET E5.1 INDICATE | | | THE USE OF A #3/0 CU GEC. FBC107 | | | | | | SHEET E4.1 | | | ADD NOTE 4 TO CIRCUIT #31 FOR EXTERIOR LIGHTING | | | | | | SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, WIND LOAD | | | ENGINEERING ARE REQUIRED FOR SITE LIGHTING. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-01-26 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-26 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-26 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2015-01-26 16:56:39 | 1/26/2015 | | | PROJECT: DUBAR SENIOR COMPLEX CLUBHOUSE | | | PERMIT#: 14120688 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET E1.1 | | | A.) PROVISIONS SHALL BE MADE TO PROVIDE EMERGENCY | | | ILLUMINATION AND EXIT LIGHTING FOR SAFE MEANS OF EGRESS | | | TO A PUBLIC RIGHT OF WAY. NFPA 101, 7.10.1.5.1, NEC | | | 700.16, NEC 700.12 | | | B.) CHANGE THE MOTION SENSOR SWITCH IN THE ELECTRICAL | | | ROOM TO A STANDARD TOGGLE SWITCH. FBC ENERGY 505.2.2 | | | EX(4) SPACES WHERE AN AUTOMATIC SHUTOFF WOULD ENDANGER | | | OCCUPANT SAFETY OR SECURITY. | | | C.) IDENTIFY THE OUTLET FOR THE DRINKING FOUNTAIN AS | | | GFCI PROTECTED. ELECTRIC DRINKING FOUNTAINS SHALL BE | | | PROTECTED WITH GROUND FAULT CIRCUIT INTERRUPTER | | | PROTECTION. NEC 422.52 | | | D.) PROVISIONS SHALL BE MADE FOR THE REQUIRED WORKING | | | CLEARANCE, DISCONNECTING MEANS AND ACCESS TO ELECTRICAL | | | EQUIPMENT FOR THE A/C AHU IN THE ATTIC SPACE. SEE NEC | | | 110.33(B), NEC 440.11, FBC-M 306.3.2 | | | E.) PROVIDE A SWITCHED LIGHT AT THE ATTIC ACCESS FOR | | | ILLUMINATION AT ELECTRICAL EQUIPMENT. SEE NEC 210.70(3) | | | | | | 2) SHEET E3.1 | | | THE PROPOSED ELECTRICAL RISER DIAGRAM MAKES REFFRENCE | | | TO A GROUNDING ELECTRODE DETAIL ON SHEET E8.3 HOWEVER | | | THERE IS NO SHEET E8.3 IN THIS SUBMITTAL PACKAGE. | | | PLEASE CLARIFY. WPB AMENDMENTS TO FBC 107.2 | | | | | | 3) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR SITE LIGHTING, GENERATORS. HOOD | | | EXHAUST, FIRE ALARM, ACCESS CONTROL SYSTEM, SECURITY, | | | CCTV, AUDIO/VIDEO, NETWORK, DATA, AND, COMMUNICATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2015-03-11 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-03-11 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-03-11 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2015-03-11 11:46:52 | ALSO BEING REVIEWED UNDER ENGINEERING APPLICATION | | | E14120027. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2015-01-02 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-01-02 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-01-02 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2015-01-02 15:35:34 | PLEASE SUBMIT APPLICATIONS FOR A DEVELOPMENT PERMIT | | | FROM THE ENGINEERING DEPARTMENT. APPLICATION FORMS CAN | | | BE FOUND AT | | | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ | | | (SECTIONS 2-421 AND 78-432, CODE OF ORDINANCES) | | | | | | ALSO SEE COMMENTS UNDER APP 14120680 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-03-04 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-03-04 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-03-04 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-02-06 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2015-02-06 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2015-02-06 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2015-02-06 15:39:27 | 820 GRANT STREET - CLUBHOUSE | | | PERMIT #14120688 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | | | | GENERAL: STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS | | | CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO | | | THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS | | | 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED | | | REFLECTIVE COLOR AND BEAR THE LETTER R DESIGNATION PER | | | FLORIDA STATUTE 633.027 AND FLORIDA ADMINISTRATIVE CODE | | | 69A-60.0081. | | | | | | GENERAL: EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED | | | SEATS SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED | | | IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE | | | ROOM. SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | SHEET A-0.01: THE TURNING RADIUS APPEARS TO BE TOO | | | SMALL TO ACCOMODATE A 47'-0" LONG LADDER TRUCK FOR THE | | | PARKING LOT ACCESS ROAD DIRECTLY SOUTH OF THE CLUBHOUSE | | | (NOT THE DROP-OFF AREA). | | | | | | SHEET A-0.04: ANOTHER EXIT SIGN IS NEEDED OUTSIDE THE | | | LOUNGE, OTHERWISE THE COMMON PATH OF TRAVEL EXCEEDS 20 | | | FOR AN AREA SERVING MORE THAN 50 PERSONS. PANIC | | | HARDWARE WILL BE NEEDED ON THE LOUNGE DOOR. | | | | | | SHEET A-0.04: INDICATE THE LOCATION/TRAVEL TO THE | | | PUBLIC WAY FOR THE NORTH EXIT. | | | | | | SHEET A-0.04: UTILITY (LAUNDRY) ROOMS SHALL BE PROVIDED | | | WITH A 1-HOUR FIRE SEPARATION AND AUTOMATIC SPRINKLER | | | PROTECTION PER SECTION 12.3.2.1.2(2)(A) OF NFPA 101. | | | | | | SHEET A-1.01: PROVIDE A PROPOSED FURNITURE LAYOUT TO | | | SUPPORT THE USE OF THE 15 SQ.FT. PER PERSON OCCUPANT | | | LOAD FACTOR. | | | | | | SHEET A-6.01: FOR ASSEMBLY OCCUPANCIES WITH AN OCCUPANT | | | LOAD OF 100 OR MORE PERSONS (50 PERSONS PER THE FLORIDA | | | BUILDING CODE), PANIC HARDWARE SHALL BE PROVIDED ON | | | DOORS TO RELEASE THE LOCK/LATCH. NO OTHER LOCKS OR | | | LATCHES ARE PERMITTED THAT WOULD NOT BE RELEASED BY THE | | | PANIC HARDWARE. AS A SUBSTITUTE FOR PANIC HARDWARE, THE | | | MAIN ENTRANCE IS PERMITTED TO HAVE AN INTERIOR KEYED | | | DOOR LOCK (AND NO LATCH) WITH A READILY VISIBLE SIGN | | | STATING THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING | | | IS OCCUPIED. SIGN LETTERS SHALL BE AT LEAST 1 INCH IN | | | HEIGHT. KEYED LOCK TO BE EQUIPPED WITH AN "OPEN/LOCKED" | | | INDICATOR WINDOW (SUCH AS ADAMS RITE 4089 OR SIMILAR). | | | A THUMB TURN STYLE LOCK IS NOT PERMITTED TO BE | | | SUBSTITUTED FOR A KEYED LOCK. | | | | | | SHEET E-1.1: COULD NOT LOCATE ANY EXIT SIGNS OR | | | EMERGENCY LIGHTS. | | | | | | SHEET FA0.1: FIRE ALARM SYSTEM SHALL BE FULLY | | | ADDRESSABLE. A CERTIFICATE OF COMPLETION AND A THIRD | | | PARTY MONITORING/VERIFICATION (UL OR ETL) CERTIFICATE | | | SHALL BE PROVIDED AT TIME OF FINAL FIRE ALARM | | | INSPECTION. | | | | | | SHEET FA1.1: INSUFFICIENT NOTIFICATION APPLIANCES | | | PROVIDED. ADDITIONALLY, PROVIDE AN EXTERIOR | | | NOTIFICATION DEVICE TO ALERT EMERGENCY RESPONDERS | | | PROMPTLY. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | FIRE INVESTIGATOR & INSPECTOR | | | OFFICE OF THE FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-05-12 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-12 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-04-03 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-04-02 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-04-02 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-02-26 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-02-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-02-10 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2014-12-22 |
Time |
19:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2015-09-08 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-09-08 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-09-08 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
N |
Date |
2015-04-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-04-27 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-04-27 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2015-03-10 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-03-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2015-03-10 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-03-10 06:04:18 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2015-01-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-12 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-01-12 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2015-01-12 16:37:07 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2015-03-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-03-19 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-03-19 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2015-03-19 11:15:52 | PASS | | | REFER TO SECTION 606.3 INSTALLATION. | | | 2010 FBC (M) ACCESS SHALL BE PROVIDED TO SMOKE | | | DETECTORS FOR INSPECTION AND MAINTENANCE. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-01-20 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-01-20 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2015-01-20 13:13:58 | PLAN DENIED | | | 1) PROVIDE DUCT SIZE ON ALL SUPPLY | | | AND RETURN AIR DUCT. PER SECTION | | | 107 FBC 2010. | | | 2) REFER TO SECTION 602.2.1 MATERIALS WITHIN | | | PLENUM'S 2010 FBC (M) INCLUDING DOORS. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-03-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-03-24 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-03-24 |
Time |
07:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-01-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-03 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-03 |
Time |
04:52 |
Sent To |
|
|
| Notes |
| 2015-01-03 08:29:46 | 1) SHT.A-1.04 REFERS TO THE USE OF MOISTURE RESISTANT | | | GYPSUM BOARD IN WET AREAS. PLEASE REFER TO FBC SEC. | | | 2509.3 FOR LIMITATIONS. | | | 2) SHT.A-5.00 - THE TOILET PAPER DISPENSER SHALL BE | | | LOCATED A MIN. OF 7 INCHES AND A MAX. OF 9 INCHES FROM | | | THE FRONT OF THE WATER CLOSET MEASURED TO THE | | | CENTERLINE OF THE DISPENSER PER THE FL. ACCESSIBILITY | | | CODE SEC. 604.7. | | | 3) SHT.A-5.00 - GRAB BARS SHALL BE MEASURED TO THE TOP | | | OF THE GRIPPING SURFACE FROM THE FINISH FLOOR NOT TO | | | THE CENTERLINE AS SHOWN. 2010 FAC SEC.609.4. | | | 4) SHT. A-5.00 - THERE ARE REFERENCES TO CODE SECTIONS | | | AND FIGURE NUMBERS OF CHAPTER 11 OF THE 2010 FAC. THESE | | | CODE SECTIONS OR FIGURE NUMBERS DO NOT EXIIST IN THE | | | 2010 FBC. PLEASE REVISE TO REFLECT THE CORRECT CODE | | | SECTIONS AND FIGURE NUMBERS. WPB AMEND. TO 2010 FBC | | | SEC. 107.2.1. | | | 5) SHT.A-5.01 - BATH PLAN A - THE PLAN VIEW SHOWS THE | | | MEASUREMENT TO THE CENTERLINE OF THE WATER CLOSET AS 18 | | | INCHES MINIMUM. THE DISTANCE SHALL BE 16-18 INCHES FROM | | | THE SIDE WALL PER THE 2010 FBC SEC.604.2. | | | 6) SHT.A-5.01 - BATH PLANS A,B & C - ELEVATIONS A & B | | | SEEM TO BE IN CONFLICT REGARDING THE HEIGHT OF THE | | | WATER CLOSET SEAT ABOVE THE FINISH FLOOR. ELEVATION A | | | SHOWS THE HEIGHT MEASURED TO THE TOP OF THE SEAT WHICH | | | IS CORRECT BUT ELEVATION B APPEARS TO HAVE THE | | | MEASUREMENT TO THE TOP OF THE TOILET BOWL. COMPLY WITH | | | THE 2010 FAC SEC.604.4. | | | 7) SHT. A-5.01 - THE GRAB BARS IN THE ELEVATION DETAILS | | | SHALL BE MEASURED FROM THE FINISH FLOOR TO THE TOP OF | | | THE GRIPPING SURFACE PER SEC. 609.4 OF THE 2010 FAC. | | | 8) SHT.A-5.01 - THE ACCESSORY SCHEDULE LISTS AN ADA | | | SHOWERHEAD BUT THE LOCATION IS NOT SHOWN ON THE PLAN. | | | CLARIFY. | | | 9) SHOW THE LOCATION OF THE SHOWER CONTROLS IN BATH | | | PLAN. COMPLY WITH 2010 FAC SEC.608.5.2 & 608.6. | | | 10) SHT. P-1.1 - SHOWS A BACKWATER VALVE ON THE | | | SANITARY LINE. BACKWATER VALVES SHALL ONLY BE INSTALLED | | | WHEN THE FLOOD LEVEL RIM OF PLUMBING FIXTURES ARE BELOW | | | THE ELEVATION OF THE MANHOLE COVER OF THE NEXT | | | UPSTREAMMANHOLE IN THE PUBLIC SEWER PER FPC SEC. 715.1. | | | REMOVE THE BACKWATER VALVE. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2015-05-08 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-08 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-05-08 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2015-05-07 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-05-07 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-05-07 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2015-05-07 09:50:06 | 1ST REVIEW: FBC 2010 | | | | | | PROVIDE SIGNATURE REPORTS FOR EACH DESIGNER. IF NO | | | LONGER PRINTABLY AVAILABLE FROM FDOT PEDDS PROGRAM, | | | PROVIDE A SCREEN SHOTS FROM THE PROGRAM TO AUTHINTICATE | | | THE SIGNATURE DOCUMENTS PROVIDED AS TIED TO THE DESIGN. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2015-02-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-02-27 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-02-27 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2015-02-27 16:44:41 | SOIL TEST REPORT SUBMITTED IN PAPER SIGNED & SEALED | | | UPLOADED DOCUMENTS TO BE REVIEWED. CP |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-04-09 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2015-04-09 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2015-04-09 |
Time |
17:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-04-02 |
|
|
Cont ID |
|
| Sent By |
ajonesva |
Date |
2015-04-02 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2015-04-02 |
Time |
12:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-01-13 |
|
|
Cont ID |
|
| Sent By |
avann |
Date |
2015-01-13 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2015-01-13 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2015-01-13 14:58:14 | 1/13/15- FAILED. 1. SITE PLAN DOES NOT MATCH APPROVED | | | SITE PLAN. | | | 2. NEED TO UNDERSTAND THE ARCHITECTURE OF THE BUILDING. | | | APPEARS TO BE DIFFERENT FROM THE CONCEPTUAL DRAWINGS | | | THE COMMISSION SAW AND APPROVED. | | | | | | | | | ANGELLA VANN. AICP | | | PLANNING AND ZONING ADMINISTRATOR | | | | | | 561-822-1441 | | | [email protected] | | | |
|
|