Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-04-28 Cont ID  
Sent By jwitmer Date 2015-04-28 Time 15:48 Rev Time 0.00
Received By jwitmer Date 2015-04-09 Time   Sent To  
Notes
2015-04-09 15:48:15BUILDING PLAN REVIEW
 PERMIT: 14120686
 ADD: 906 GRANT ST.
 CONT: T. B. D. /AYALA MANUEL
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
 3RD REVIEW
 DATE: THURS. APRIL 09/2015
 ACTION: DENIED
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL.CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION OF WORK TO BE
 COMPLETED UNDER THIS PERMIT.
  
 THE ONLY DIFFERENCE IN THE COMMENTS WILL BE IN THE UNIT
 WILL AFFECT THE COMMENT 4A)(1-2) , THIS COMMENT DEALS
 WITH THE ASSEMBLY OCCUPANCY IN THE 49 UNIT APPRTMENT
 BUILDING.
  
 1-2) COMPLIED.
  
 3RD REQUEST. 3) 4/28/2015. COMPLIED, THE CONTRACTOR
 WILL PRODUCE A JOB SUMMARY OR HISTORY FOR THIS TYPE OF
 CONSTRUCTION.
  
 NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE REQUIRED.
 FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE PERMIT
 LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND BATCH
 STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO SETS OF
 PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR THE
 RESIDENT INSPECTOR, THE OTHER FOR THE MEP INSPECTORS.
  
 PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED
 TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR
 IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE
 INSPECTIONS.
  
 4-6) COMPLIED.
  
 .1.2.
  
 7) PAGE 49 SHEET 1A-0.40 ROOF ACCESS & ROOF PLAN:
 7A-D) COMPLIED.
  
 7E) DEFERRED SUBMITTAL, ROOF TOP INSULATION PROVIDE THE
 ROOFTOP PRODUCT APPROVAL FOR INSULATION, LAYOUT SHEET
 FOR SLOPE AND ANCHORS TO BE SUBMITTED TO THE DESIGNER
 OF RECORD, REVIEWED, AND SHOP DRAWING STAMP OF APPROVAL
 AND OR WITH NOTES BEFORE SUBMITTAL TO THE BUILDING
 DEPARTMENT.
  
  
 7F) COMPLIED.
  
 8) BUILDING PROVISO
 THE OWNER/ CLIENT WILL OPT TO GET A FIELD TEST FROM A
 NATIONALLY RECONIZED TESTING AGENCY BEFORE A
 CERTIFICATE OF OCCUPANCY WILL BE ISSUED. AT OWN RISK
 NOT SUPPLYING TESTED ASSEMBLIES BEFORE PERMIT ISSUANCE.
 SITE TESTING FOR AIR-BORNE SOUND SHALL CONFORM TO ASTM
 E 90, WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED).
  
  
 9) BUILDING PROVISO: 4/24/2015 REG ARCHITECTS ELECTS TO
 COMPLY WITH FIELD TESTING TO COMPLY WITH ASTM E-90. THE
 SUBMITTED INTERTEK REPORT # 3053682-001A IS FOR SOUND
 SEAL / CERAZORB 5 MM TESTED TO ASTM E 492 WITH RESULTS
 OF IIC OF 50. NOTE TO DATE THERE HAS BEEN NO TESTING
 SUBMITTED FOR ) FBC-B 2010 1207.2 1207.2 AIR-BORNE
 SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 10 BUILDING PROVISO: PRODUCT APPROVALS WILL BE
 SUBMITTED AFTER PERMIT ISSUANCE AS A DEFERRED
 SUBMITTAL. 107.3.4.2 DEFERRED SUBMITTALS. FOR THE
 PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
 TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 (E) SHUTTERS
 (F) SKYLIGHTS
 (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C
 STANDS
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-03-09 Cont ID  
Sent By jwitmer Date 2015-03-09 Time 16:39 Rev Time 0.00
Received By jwitmer Date 2015-03-09 Time 07:03 Sent To  
Notes
2015-03-09 14:13:31BUILDING PLAN REVIEW
 PERMIT: 14120686 BLDG # 2 / 50 UNITS
 ADD: 906 GRANT ST.
 CONT: T. B. D. /AYALA MANUEL
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015
 ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED
 ELECTRONICALLY
 UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS
 SUBMISSION OPTIONS ARE AS FOLLOWS:
 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL
 SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED
 NAMING CONVENTION FOR EACH DOCUMENT
 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER
 DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE
 REQUIRED NAMING CONVENTION FOR EACH DOCUMENT
 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT
 TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS
 ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES
 AVAILABLE
  
 2ND REVIEW
 DATE: MON. MARCH 09/ 2015
 ACTION: DENIED
  
 NOTICE: !!!!!!!!!!!!!!! THE PERMIT APPLICATIONS NEED TO
 REFLECT THE CORRECT ADDRESS. THE PERMIT APPLICATIONS
 DOES NOT STATE BLDG. # 1 / 49 UNITS OR BLDG # 2 / 50
 UNITS. MY PLAN REVIEWS ARE AS FOLLOWS UNDER PERMIT #
 14120680 BLDG #1/ 49 UNITS AND PERMIT # 14120686 BLDG #
 2 /50 UNITS. CURRENTLY IT LOOKS LIKE THE BLDG COMMENTS
 FOR EACH BUILDING ARE UNDER THE WRONG PERMIT NUMBER
 SINCE WE TOOK BLDG # 1 WITH THE LOWER PERMIT NUMBER AS
 BLDG # 114120680 AND BLDG # 2 AS PERMIT # 14120686.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL.CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION OF WORK TO BE
 COMPLETED UNDER THIS PERMIT.
  
 THE ONLY DIFFERENCE IN THE COMMENTS WILL BE IN THE UNIT
 WILL AFFECT THE COMMENT 4A)(1-2) , THIS COMMENT DEALS
 WITH THE ASSEMBLY OCCUPANCY IN THE 49 UNIT APPRTMENT
 BUILDING.
  
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION INFORMATION ON
 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE
 MATERIAL.CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION OF WORK TO BE
 COMPLETED UNDER THIS PERMIT.
  
 1-2) COMPLIED.
  
 2ND REQUEST. 3) THIS PROJECT QUALIFIES FOR A RESIDENT
 INSPECTOR UNDER 2010 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION,
 110.3.9 OTHER INSPECTIONS SERVICES. THE BUILDING
 OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY OTHERS, THE
 INSPECTIONS REQUIRED BY SECTION 109. HE/SHE MAY ACCEPT
 REPORTS OF INSPECTORS OF RECOGNIZED INSPECTION
 SERVICES, PROVIDED THAT AFTER INVESTIGATION HE/SHE IS
 SATISFIED AS TO THEIR QUALIFICATIONS AND RELIABILITY. A
 CERTIFICATE CALLED FOR BY ANY PROVISION OF THE
 TECHNICAL CODES SHALL NOT BE BASED ON SUCH REPORTS
 UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY A
 RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING
 OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION
 SERVICE IN THE FOLLOWING INSTANCES:
 FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE FOOT
 FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT
 FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR
 METHODS OF CONSTRUCTION, TUNNEL FORM
  
 RESIDENT INSPECTOR BOOKLET & FORMS WILL BE E-MAILED TO:
 /AYALA MANUEL, E-MAIL: [email protected] SENT AT
 8:15 AM 01/12/2015
 THE RESIDENT INSPECTOR FORMS ARE TO BE COMPLETED AND
 RETURNED BACK TO THE CONSTRUCTION SERVICES DIVISION
 BEFORE PERMIT ISSUANCE.
  
 2ND REQUEST. 3A) DIGITAL REVIEW, ONCE THE PLANS ARE
 BATCH STAMPED, THE PERMIT IS ISSUED, PLEASE NOTIFY THE
 PERMIT LIBRIAN CAROLINE PUELL TO DOWN LOAD THE PLANS TO
 THE CONTACT PERSON, NOTE (2) COLOR SETS OF PLANS WILL
 NEED TO BE PRINTED, ONE FOR THE RESIDENT INSPECTOR THE
 OTHER FOR THE CITY MEP INSPECTORS.
  
 2ND REQUEST. 3B) PLEASE REMEMBER TO CALL IN ALL
 STRUCTURAL INSPECTIONS SINCE KEN CONRAD WILL BE
 AUDITING INSPECTIONS, ALSO IF THERE IS NO RECORD OF
 CALLED IN INSPECTIONS AFTER 6 MONTHS OF NO ACTIVITY THE
 PERMIT WILL EXPIRE. WPB ADMINISTRATIVE CODE 110.5
 INSPECTION REQUESTS. IT SHALL BE THE DUTY OF THE HOLDER
 OF THE BUILDING PERMIT OR THEIR DULY AUTHORIZED AGENT
 TO NOTIFY THE BUILDING OFFICIAL WHEN WORK IS READY FOR
 INSPECTION. IT SHALL BE THE DUTY OF THE PERMIT HOLDER
 TO PROVIDE ACCESS TO AND MEANS FOR INSPECTIONS OF SUCH
 WORK THAT ARE REQUIRED BY THIS CODE
  
 2ND REQUEST. 3C) 2010 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION,
 110.3.9 OTHER INSPECTIONS SERVICES. SUCH INSPECTORS
 SHALL BE ADEQUATELY PRESENT AT TIMES WORK IS UNDERWAY
 ON THE STRUCTURAL ELEMENTS OF THE BUILDING. SUCH
 INSPECTORS SHALL BE A REGISTERED ARCHITECT, OR
 ENGINEER, OR A PERSON LICENSED UNDER CHAPTER 468, PART
 XII, FLORIDA STATUTES. SUCH INSPECTORS SHALL SUBMIT
 WEEKLY PROGRESS REPORTS INCLUDING THE DAILY INSPECTIONS
 TO THE BUILDING OFFICIAL, AND INCLUDING A CODE
 COMPLIANCE OPINION OF THE RESIDENT INSPECTOR.
  
 4) PAGE 043 FIRST FLOOR LIFE SAFETY:
  
 4A) 2ND REQUEST!!! OCCUPANCY COUNT:
  
 EXAMPLE 1: COMPLIED. UNIT 111 IS 793 SQ. FT./ 200=
 3.965IN EVERY CASE THE DESIGNER HAS DROPPED THE
 FRACTION OF AN OCCUPANT, YOU ROUND UP NOT DOWN TO THE
 NEXT WHOLE
 NUMBER. FBC-B 1004.1. ALSO SEE BOAF INFORMAL
 INTERPRETATION 5479.
  
 4A) (1)2ND REQUEST. EXAMPLE 2: UNIT 110 IS LISTED AS A
 R OCCUPANCYFOR THIS BUILDING THIS IS A A-3 ASSEMBLY
 USAGE WITH A OCCUPANT LOADING FACTOR OF 15= 40
 OCCUPANTS. THIS UNIT STILL SHOWS AS A (R) RESIDENTIAL
 UNIT AND OCCUPANT LOADING @ 200 SQ. FT/ OCCUPANT.
  
 4A)(2) NEW NOTE. THE COMMOM WALL BETWEEN UNIT 110 (A3
 ASSEMBLY) & UNIT 111 (R2) IS A OCCUPANCY SEPARATION
 WALL. 2010 FBC-B TABLE 508.4 REQUIRES A 2 HR FIRE
 SEPARATION WALL, NO REDUCTION IS GIVEN FOR A R-13 FIRE
 SPRINKLER SYSTEM. SEE FOOTNOTE S.
  
  
 4B) SEMI-COMPLIED. UNITS 103 & 116 THE WINDOWS & DOORS
 IN THE FRONT OF THE UNIT WILL NEED TO BE 3/4 HR FIRE
 RATED EVEN THOUGH THERE IS 2 MEANS OF EGRESS, PLEASE
 SEE THE UNITS
 ON THE 2ND & 3RD FLOOR WITH DEAD END CONDITIONS.
 NEW NOTE: WITH THE 3/4 HR. FIRE RATING FOR THE WINDOWS
 THE REQUIREMENT FOR LARGE MISSILE RESISTANT RATED
 WINDOWS STILL EXIST. THE DESIGNER OF RECORD HAS THE
 CHOICE FOR THE FIRE
 RATED GLAZING & TESTING FOR LARGE MISSILE IMPACT
 GLAZING (VERY, VERY EXSPENSIVE) OR STORM SHUTTERS, IF
 STORM SHUTTERS ARE THE OPTION TO MEET CODE COMPLIANCE
 THE CITY WILL ALSO
 NEED PRODUCT APPROVAL TESTING FOR THE SHUTTER SYSTEM
 AND A SHUTTER SCHEDULE.
  
 PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.2.
  
 FL BLD CODE 2010 SECTION 107.2.5., & 1609.1.2, 1715.8
 PROCEDURES: A COMPLETE INSTALLATION SCHEDULE
 SUMMARIZING & IDENTIFYING OPENING SIZES, STORY HEIGHTS,
 UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR
 REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT
 TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT
 APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
  
 5) PAGE 044 2ND FLOOR LIFE SAFETY:
 5A) COMPLIED. UPDATE OCCUPANT LOADS.
  
 5B) SEMI-COMPLIED. UNITS 203 & 216, 3/4 HR FIRE RATING
 & STORM SHUTTERS (IF ELECTING STORM SHUTTERS). SEE
 COMMENT 4B.
  
 6) PAGE 045 3RD FLOOR LIFE SAFETY:
  
 5A) COMPLIED. UPDATE OCCUPANT LOADS.
  
 6B) SEMI-COMPLIED. UNIT 316, DEAD END CORRIDORS THE
 WINDOWS IN THE FRONT OF THE UNIT WILL NEED TO BE 3/4 HR
 FIRE RATED. IF ELECTING STORM SHUTTERS PROVIDE STORM
 PANEL INFORMATION WITH INSTALLATION SCHEDULE AND KEY
 PLAN WITH SPECIFIC ANCHORS AND MOUNTING TO BE USED FOR
 ALL NON-IMPACT GLAZING. FBC 1609.1.2.
  
 7) PAGE 49 SHEET 1A-0.40 ROOF ACCESS & ROOF PLAN:
 7A-C) COMPLIED.
  
 7D) 2ND REQUEST. RESPOSE SEE PAGE 109 - M5.2 DETAIL #
 4. THIS DETAIL SHOWS THE ROOF TOP CONDENSOR STAND BASE
 PLATE BEING INSTALLED ON TOP OF THE BUILT UP ROOF, TWO
 ISSUES, ONE THERE IS NO PITCH PAN NOR IS THERE SHOWN
 THE ROOF TOP INSULATION AND HOW THIS EFFECTS THE
 FASTENING TO THE DECK.
 1507.1 SCOPE.
 ROOF COVERINGS SHALL BE APPLIED IN ACCORDANCE WITH THE
 APPLICABLE PROVISIONS OF THIS SECTION AND THE
 MANUFACTURER?S INSTALLATION INSTRUCTIONS.
 COMMENT FROM 1ST REVIEW. PLEASE PROVIDE HOW THE A/C
 CONDENSOR ROOF TOP UNITS ARE GOING TO BE SECURED TO THE
 ROOF RACKS AND HOW THE ROOF RACKS ARE GOING TO BE
 SECURED TO THE CONCRETE ROOF DECK. PLEASE ALSO BE AWARE
 OF FBC-B TABLE 1509.7.
  
 7E) DEFERRED SUBMITTAL, ROOF TOP INSULATION PROVIDE THE
 ROOFTOP PRODUCT APPROVAL FOR INSULATION, LAYOUT SHEET
 FOR SLOPE AND ANCHORS TO BE SUBMITTED TO THE DESIGNER
 OF RECORD, REVIEWED, AND SHOP DRAWING STAMP OF APPROVAL
 AND OR WITH NOTES BEFORE SUBMITTAL TO THE BUILDING
 DEPARTMENT.
  
  
 7F) NEW COMMENT, DEALING WITH THE ROOF TOP ACCESS AND
 THE CENTER STAIRWAY. PLEASE REVIEW PAGES 056/ A1-1.04,
 076-A1.401 DETAIL # 3 & 093-A-9.01 THE FLOORS 1-3 SHOW
 A OPEN STAIRWAY BUT THE STAIR GOING TO THE 4TH FLOOR
 ROOF TOP FLOOR SHOWS THE STAIR AS AN ENCLOSED
 STAIRWELL. PLEASE REVIEW:
 2010 FBC-B 1026.3 OPEN SIDE. EXTERIOR EXIT RAMPS AND
 STAIRWAYS SERVING AS AN ELEMENT OF A REQUIRED MEANS OF
 EGRESS SHALL NOT LESS THAN 50 PERCENT OPEN ON ONE SIDE.
 OUTSIDE STAIRS SHALL BE ARRANGED TO RESTRICT THE
 ACCUMULATION OF SMOKE.
  
 8) 2ND REQUEST. NEW SHEET084-1/ 1A-6.02 PLEASE PROVIDE
 THE ACTUAL TESTING REPORTS FOR THE KNAUF BATT
 INSULATION IN ACCORDANCE WITH 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90. PENETRATIONS OR OPENINGS IN CONSTRUCTION
 ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED
 CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR
 EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED OR
 OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS.
 THIS REQUIREMENT SHALL NOT APPLY TO DWELLING UNIT
 ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT
 FITTING TO THE FRAME AND SILL.
  
  
  
  
  
 9) 2ND REQUEST. A NEW SHEET 084-1/ 1A-6.02 PROVIDES
 THAT EASY MAT WITH SOUNDGUARD 5MM TO BE USED FOR THE
 INSTALLATION. THE TEST THIS PRODUCT WAS TESTED ASTM
 E-2179-03 IS THE WRONG TEST , IT IS TO BE TESTED TO
 EITHER ASTM E 90 WITH A STC RATING OF NOT LESS THAN 50
 OR ASTM E 492 IMPACT INSULATION OF NO TLESS THAN 50
 (IIC). PROVIDE THE ACTUAL TESTING REPORT.
  
 THE PLANS DO NOT SHOW COMPLIANCE WITH IS 2010 FBC-B
 1207.3 STRUCTURE-BORNE SOUND. FLOOR/CEILING ASSEMBLIES
 BETWEEN DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A
 PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE
 AN IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS
 THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE
 WITH ASTM E 492.
  
 10) PAGE 085 1A-7.01 WINDOW BUCK DETAIL # 4 IS ACTUALLY
 DRAWN WRONG, THE CODE SECTION DIRECTLY ABOVE IR STATES
 UNLESS OTHERWISE TWESTED BUCKS SHALL EXTEND BEYOND THE
 INTERIOR SURFACE OF THE WINDOE OR DOOR FRAME. FBC-B
 1715.5.4.2.
  
 11) PAGE 87 1A-7.03 DETAIL 3 INDICATES THE HAND RAIL @
 34 IN. A.F.F. PLEASE REVIEW FBC-B 1012.2 THE HEIGHT IS
 TO BE MEASURED FROM THE TREAD NOSING.
  
 12) THE PRESSURES FOR THE ROOF FLAT SECTION ARE GOOD,
 NO ROOF ZONE 3 THE PAARAPET IS AT LEAST 3'-0" HIGH
 ELIMINATING ZONE 3. WINDOW AND DOOR PRESSURES ARE GOOD
 FOR A MEAN ROOF HEIGHT OF 32.5 FT. THE ISSUE WILL BE
 THE ROOF LEVEL OF THE PENTHOUSE SINCE THE LOCATION IS
 ABOVE 33 FT, NO SHINGLES MAY BE PUT ON A ROOF WITH A
 MEAN ROOF HEIGTH OF 33 FT, SEE NOA LIMITATION. IF THE
 WHOLE ROOFING STYLE IS TO CHANGE FROM SHINGLES THEN
 PRESSURES FOR A 4/12 ROOF WILL BE NEEDED FOR BOTH A
 MEAN ROOF HEIGHT OF 32.5 FT AND PENTHOUSE AT APPROX
 41.0. FT.
  
 13) THE PRODUCT APPROVALS DO NOT HAVE TO BE SUBMITTED
 AT THIS TIME. AS LONG AS THE WIND DESIGN AND PRESSURES
 ARE CORRECT, THE PRODUCT APPROVALS CAN BE SUBMITTED
 AFTER PERMIT ISSUANCE AS A DEFERRED SUBMITTAL, NO COST
 TO CONTRACTOR. THERE IS NO CONTRACTOR SIGNED ON, THEY
 THEN BID THE JOBS OUT, THE PRODUCT APPROVALS SUBMITTED
 TODAY MAY NOT BE WHAT IS ACTUAL SUBMITTED TO BE BUILT.
 IF THE DESIGNER OF RECORD WOULD PREFER TO HAVE THE
 PRODUCT APPROVALS DEFERRRED IN THE RESPONCE JUST NOTE
 SO.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2 DEFERRED
 SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED
 SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN
 THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION
 AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL
 WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL
 ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING
 OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS
 ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE
 BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL
 ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW
 THEM AND FORWARD THEM TO THE
 BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND
 FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE
 BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE
 INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN APPROVED BY THE BUILDING OFFICIAL.
  
 13A) NOA 12-0320.07 SUNSHINE 2000 SERIES SINGLE HUNG,
 LMI PLEASE CIRCLE THE UNITS HEIGHT, WIDTH, PRESSURES &
 ANCHORAGE.
  
 13B) NOA 13-0122.05 SUNSHINE 8000 SERIES STOREFRONT,
 LMI PLEASE CIRCLE THE UNITS HEIGHT, WIDTH, PRESSURES &
 ANCHORAGE.
  
 13C) NOA 11-1216.02 SUNSHINE MULLION CIRCLE WIDTH,
 SPAN, MULLION SIZE PRESSURES AND TYPE OF ANCHORS.
  
 13D) NOA 14-0109.06 SUNSHINE ALUMINUM, OUTSWING FRENCH
 DOORS NOTE FLUSHBOLTS WILL NEED TO WORK FROM A WHEEL
 CHAIR POSITION, PLEASE CIRCLE THE UNITS HEIGHT, WIDTH,
 PRESSURES & ANCHORAGE.
  
 13E) FL. 14237-R1 FLEMING BARON CIRCLE IF SINGLE OR
 PAIR, INSWEING OR OUT, TYPE OF LATCH ANCHORAGE AND
 ASSOCIATED PRESSURES.
  
 13F) JOHN MANSVILLE TPO SINGLE PLY ROOFING OVER
 LIGHTWEIGHT CONCRETE DECK. NOA 14-0618.05 CIRCLE WHICH
 SUB-SYSTEM TO BE INSTALLED AND ASSOCIATED PRESSURES.
  
 13G) NOA 13-1104.12 GAF TIMBERLINE ULTRA HD
 SHINGLESNOTE THIS PRODUCT UNDER LIMITATIONS IS NOT TO
 BE INSTALLED ABOVE 33 FT. THE PENTHOUSE ROOF IS WELL
 ABOVE THE 33 FT MEAN ROOF HEIGHT.
  
 13H) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 14A) THE ENERGY CALCULATIONS INDICATE A VENTED ATTIC
 AND R-19 INSULATION, LOCATED WHERE?
  
 14B) ROOF VENTILATION PAGE 049, 1A-0.40 THE PLANS
 INDICATE THE USE OF SOFFIT VENTILATION BUT DO NOT
 INDICATE COMPLIANCE WITH FBC-B 1203.2 50 PERCENT OF THE
 REQUIRED VENTILATING AREA PROVIDED BY VENTILATORS
 LOCATED IN THE UPPER PORTION OF THE SPACE TO BE
 VENTILATED AT LEAST 3 FEET (914 MM) ABOVE EAVE OR
 CORNICE VENTS WITH THE BALANCE OF THE REQUIRED
 VENTILATION PROVIDED BY EAVE OR CORNICE VENTS.
  
 15) THE ENERGY CALCULATIONS WILL NEED TO REFLECT THE
 VALUES FOR A1 END UNIT, B UNIT INTERIOR AS WELL AS A
 END UNIT, AND A A2 INTERIOR UNIT, ALL ON GRADE, THEN
 FOR 2ND FLOOR SUROUNDED ABOVE AND BELOW WITH A/C AND
 THE 3RD FLOOR UNITS WITH ROOF INSULATION OVERHEAD.
  
 16) PLEASE PROVIDE THE WINDOW AND DOOR SHGC OF 0.5
 FBC-ENERGY 402.3.
  
 17) LIFE SAFETY SHEETS TO SHOW AREA OF RESCUE
 ASSISTANCE 2010 FBC-ACCESSIBILITY CODE 207.1. SEE
 SECTION 1007 OF THE 2003 IBC 107.6 AREA OF REFUGE.
  
 18) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 19) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-01-13 Cont ID  
Sent By jwitmer Date 2015-01-13 Time 08:07 Rev Time 0.00
Received By jwitmer Date 2015-01-13 Time 06:36 Sent To  
Notes
2015-01-13 07:07:59BUILDING PLAN REVIEW
 PERMIT: 14120686
 ADD: 806 GRANT ST.
 CONT: T. B. D. /AYALA MANUEL
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JAN. 13/ 2015
 ACTION: DENIED
  
 NOTE, THE PERMIT APPLICATION HAS THE ADDRESS OF 906
 GRANT ST, SHOULDN' T IT BE 806 GRANT ST. THE PCN OF
 74434316230010010 ALSO DOES NOT EXIST!!!!!!
 1) FRAME 42/ 1A-0.03;
  
 1A) PAGE 042 1A-0.03 CODE INFORMATION SHEET. UNDER THE
 HEADING CODE RESEARCH & TABULATION, MAXIMUM AREA FOR
 BLDG. # 1 THE AREA FOR THE 1ST FLOOR IS 17,614 SQ. FT.
 (PROVIDED), 21,000 SQ. FT. (ALLOWED) SINCE THIS IS A
 13R SPRINKLER SPRINKLER INCREASES CAN NOT BE TAKEN,
 PLEASE SHOW CALCULATIONS FOR THE FRONTAGE INCREASES
 TAKEN SEE 2010 FBC-B 506.2.
  
 1B) TABLE FOR RATED FIRE RESISTANCE PERIODS FOR VARIOUS
 WALLS AND PARTITIONS TABLE 720.1(2) PLEASE PROVIDE WHAT
 THE MINIMUM COVERAGE WILL BE FOR WALLS AND SLABS, THE
 INSPECTORS WILL NOT HAVE THEIR CODE BOOKS TO LOOK UP
 THE MINIMUM COVERAGE FOR A REQUIRED 1 HR FIRE RATING.
  
 1C) TABLE FOR RATED FIRE RESISSTANCE PERIODS FOR
 VARIOUS WALLS AND PARTITIONS TABLE 720.1(2) IS THE ONLY
 TABLE LISTED FOR STRUCTURAL ELEMENTS, PLEASE REVIEW THE
 STRUCTURAL SHEETS FOR THE 2ND FLOOR AND 3RD FLOOR, SC-1
 STEEL COLUMNS DO NOT PROVIDE HOW THEY ARE GOING TO BE
 FIRE RESISTANCE PROTECTED, THEY MAY BE ON THE EXTERIOR,
 BUT THEY ARE ALSO WITHIN 10 FT. OF GLAZED OPENINGS THAT
 IN A FIRE INCIDENT WILL BE AFFECTED, PARTOF THE
 STRUCTURAL SYSTEM. TABLE 601.
  
 2) SHEET S4.2 INDICATES THE EXISTANCE OF ASOILS REPORT
 BY ARDAMIN & ASSOC. FILE# 14-1657 MAY 23/ 14TH. PLEASE
 SUBMIT 3 ORIGINAL SIGNED & SEALED REPORTS.
  
 3) THIS PROJECT QUALIFIES FOR A RESIDENT INSPECTOR
 UNDER 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION,
 110.3.9 OTHER INSPECTIONS SERVICES. THE BUILDING
 OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY OTHERS, THE
 INSPECTIONS REQUIRED BY SECTION 109. HE/SHE MAY ACCEPT
 REPORTS OF INSPECTORS OF RECOGNIZED INSPECTION
 SERVICES, PROVIDED THAT AFTER INVESTIGATION HE/SHE IS
 SATISFIED AS TO THEIR QUALIFICATIONS AND RELIABILITY. A
 CERTIFICATE CALLED FOR BY ANY PROVISION OF THE
 TECHNICAL CODES SHALL NOT BE BASED ON SUCH REPORTS
 UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY A
 RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING
 OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION
 SERVICE IN THE FOLLOWING INSTANCES:
 FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE FOOT
 FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT
 FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR
 METHODS OF CONSTRUCTION, TUNNEL FORM
  
 RESIDENT INSPECTOR BOOKLET & FORMS WILL BE E-MAILED TO:
 /AYALA MANUEL, E-MAIL: [email protected] SENT AT
 8:15 AM 01/12/2015
 THE RESIDENT INSPECTOR FORMS ARE TO BE COMPLETED AND
 RETURNED BACK TO THE CONSTRUCTION SERVICES DIVISION
 BEFORE PERMIT ISSUANCE.
  
 3A) DIGITAL REVIEW, ONCE THE PLANS ARE BATCH STAMPED,
 THE PERMIT IS ISSUED, PLEASE NOTIFY THE PERMIT LIBRIAN
 CAROLINE PUELL TO DOWN LOAD THE PLANS TO THE CONTACT
 PERSON, NOTE (2) COLOR SETS OF PLANS WILL NEED TO BE
 PRINTED, ONE FOR THE RESIDENT INSPECTOR THE OTHER FOR
 THE CITY MEP INSPECTORS.
  
 3B) PLEASE REMEMBER TO CALL IN ALL STRUCTURAL
 INSPECTIONS SINCE KEN CONRAD WILL BE AUDITING
 INSPECTIONS, ALSO IF THERE IS NO RECORD OF CALLED IN
 INSPECTIONS AFTER 6 MONTHS OF NO ACTIVITY THE PERMIT
 WILL EXPIRE. WPB ADMINISTRATIVE CODE 110.5 INSPECTION
 REQUESTS. IT SHALL BE THE DUTY OF THE HOLDER OF THE
 BUILDING PERMIT OR THEIR DULY AUTHORIZED AGENT TO
 NOTIFY THE BUILDING OFFICIAL WHEN WORK IS READY FOR
 INSPECTION. IT SHALL BE THE DUTY OF THE PERMIT HOLDER
 TO PROVIDE ACCESS TO AND MEANS FOR INSPECTIONS OF SUCH
 WORK THAT ARE REQUIRED BY THIS CODE
  
 3C) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER
 INSPECTIONS SERVICES. SUCH INSPECTORS SHALL BE
 ADEQUATELY PRESENT AT TIMES WORK IS UNDERWAY ON THE
 STRUCTURAL ELEMENTS OF THE BUILDING. SUCH INSPECTORS
 SHALL BE A REGISTERED ARCHITECT, OR ENGINEER, OR A
 PERSON LICENSED UNDER CHAPTER 468, PART XII, FLORIDA
 STATUTES. SUCH INSPECTORS SHALL SUBMIT WEEKLY PROGRESS
 REPORTS INCLUDING THE DAILY INSPECTIONS TO THE BUILDING
 OFFICIAL, AND INCLUDING A CODE COMPLIANCE OPINION OF
 THE RESIDENT INSPECTOR.
  
 4) PAGE 043 FIRST FLOOR LIFE SAFETY:
 4A) THE LIFE SAFETY LEGEND DEPICT A TAG WITH OCCUPANCY,
 SQUARE FT. , OCCUPANT LOAD FACTOR AND NUMBER OF
 OCCUPANTS, WHEN YOU LOOK AT ANY UNIT YOU WILL SEE THE
 SAME ISSUE,:
 EXAMPLE 1: UNIT 111 IS 793 SQ. FT./ 200= 3.965IN EVERY
 CASE THE DESIGNER HAS DROPPED THE FRACTION OF AN
 OCCUPANT, YOU ROUND UP NOT DOWN TO THE NEXT WHOLE
 NUMBER. FBC-B 1004.1. ALSO SEE BOAF INFORMAL
 INTERPRETATION 5479.
  
 4B) UNITS 103 & 116 THE WINDOWS & DOORS IN THE FRONT OF
 THE UNIT WILL NEED TO BE 3/4 HR FIRE RATED EVEN THOUGH
 THERE IS 2 MEANSA OF EGRESS, PLEASE SEE THE UNITS ON
 THE 2ND & 3RD FLOOR WITH DEAD END CONDITIONS.
 2010 FBC-B 1019.2 WALL SEPARATION. EXTERIOR EGRESS
 BALCONIES SHALL BE SEPARATED FROM THE INTERIOR OF THE
 BUILDING BY WALLS AND OPENING PROTECTIVES AS REQUIRED
 FOR CORRIDORS. EXCEPTION: SEPARATION IS NOT REQUIRED
 WHERE THE EXTERIOR EGRESS BALCONY IS SERVED BY AT LEAST
 TWO STAIRS AND A DEAD-END TRAVEL CONDITION DOES NOT
 REQUIRE TRAVEL PAST AN UNPROTECTED OPENING TO REACH A
 STAIR. 026.6 EXTERIOR RAMPS AND STAIRWAY PROTECTION.
 EXTERIOR EXIT RAMPS AND STAIRWAYS SHALL BE SEPARATED
 FROM THE INTERIOR OF THE BUILDING AS REQUIRED IN
 SECTION 1022.1 ALSO SEE 2007 FBC-B CODE COMMENTARY
 FIGURE 1023.6(1).
  
 5) PAGE 044 2ND FLOOR LIFE SAFETY:
 5A) UPDATE OCCUPANT LOADS TO REFLECT PARTIAL OCCUPANTS
 ROUNDED UP TO WHOLE PEOPLE, SEE COMMENT 4A EXAMPLE 1,
 FBC-B 1004.1 BOAF INFORMAL INTERPRETATION 5479.
  
 5B) UNITS 203 & 216, DEAD END CORRIDORS THE WINDOWS IN
 THE FRONT OF THE UNIT WILL NEED TO BE 3/4 HR FIRE
 RATED.
 2010 FBC-B 1019.2 WALL SEPARATION. EXTERIOR EGRESS
 BALCONIES SHALL BE SEPARATED FROM THE INTERIOR OF THE
 BUILDING BY WALLS AND OPENING PROTECTIVES AS REQUIRED
 FOR CORRIDORS. EXCEPTION: SEPARATION IS NOT REQUIRED
 WHERE THE EXTERIOR EGRESS BALCONY IS SERVED BY AT LEAST
 TWO STAIRS AND A DEAD-END TRAVEL CONDITION DOES NOT
 REQUIRE TRAVEL PAST AN UNPROTECTED OPENING TO REACH A
 STAIR. 026.6 EXTERIOR RAMPS AND STAIRWAY PROTECTION.
 EXTERIOR EXIT RAMPS AND STAIRWAYS SHALL BE SEPARATED
 FROM THE INTERIOR OF THE BUILDING AS REQUIRED IN
 SECTION 1022.1 ALSO SEE 2007 FBC-B CODE COMMENTARY
 FIGURE 1023.6(1).
  
 6) PAGE 045 3RD FLOOR LIFE SAFETY:
 5A) UPDATE OCCUPANT LOADS TO REFLECT PARTIAL OCCUPANTS
 ROUNDED UP TO WHOLE PEOPLE, SEE COMMENT 4A EXAMPLE 1,
 FBC-B 1004.1 BOAF INFORMAL INTERPRETATION 5479.
  
 6B) UNIT 216, DEAD END CORRIDORS THE WINDOWS IN THE
 FRONT OF THE UNIT WILL NEED TO BE 3/4 HR FIRE RATED.
 2010 FBC-B 1019.2 WALL SEPARATION. EXTERIOR EGRESS
 BALCONIES SHALL BE SEPARATED FROM THE INTERIOR OF THE
 BUILDING BY WALLS AND OPENING PROTECTIVES AS REQUIRED
 FOR CORRIDORS. EXCEPTION: SEPARATION IS NOT REQUIRED
 WHERE THE EXTERIOR EGRESS BALCONY IS SERVED BY AT LEAST
 TWO STAIRS AND A DEAD-END TRAVEL CONDITION DOES NOT
 REQUIRE TRAVEL PAST AN UNPROTECTED OPENING TO REACH A
 STAIR. 026.6 EXTERIOR RAMPS AND STAIRWAY PROTECTION.
 EXTERIOR EXIT RAMPS AND STAIRWAYS SHALL BE SEPARATED
 FROM THE INTERIOR OF THE BUILDING AS REQUIRED IN
 SECTION 1022.1 ALSO SEE 2007 FBC-B CODE COMMENTARY
 FIGURE 1023.6(1).
  
 7) PAGE 49 SHEET 1A-0.40 ROOF ACCESS & ROOF PLAN:
 7A) ROOF PLAN AND ROOF ACCESS SHOWS THE ELEVATOR
 CONTROL CLOSET WITHIN THE VERTICAL EXIT.2010 FBC-B AN
 EXIT ENCLOSURE SHALL NOT BE USED FOR ANY PURPOSE OTHER
 THAN MEANS OF EGRESS.
 1022.4 PENETRATIONS. PENETRATIONS INTO AND OPENINGS
 THROUGH AN EXIT ENCLOSURE ARE PROHIBITED EXCEPT FOR
 REQUIRED EXIT DOORS, EQUIPMENT AND DUCTWORK NECESSARY
 FOR INDEPENDENT VENTILATION OR PRESSURIZATION,
 SPRINKLER PIPING, STANDPIPES, ELECTRICAL RACEWAY FOR
 FIRE DEPARTMENT COMMUNICATION SYSTEMS AND ELECTRICAL
 RACEWAY SERVING THE EXIT ENCLOSURE AND TERMINATING AT A
 STEEL BOX NOT EXCEEDING 16 SQUARE INCHES (0.010 M2).
 SUCH PENETRATIONS SHALL BE PROTECTED IN ACCORDANCE WITH
 SECTION 713. THERE SHALL BE NO PENETRATIONS OR
 COMMUNICATION OPENINGS, WHETHER PROTECTED OR NOT,
 BETWEEN ADJACENT EXIT ENCLOSURES.
 1022.3 OPENINGS AND PENETRATIONS.EXIT ENCLOSURE OPENING
 PROTECTIVES SHALL BE IN ACCORDANCE WITH THE
 REQUIREMENTS OF SECTION 715. OPENINGS IN EXIT
 ENCLOSURES OTHER THAN UNPROTECTED EXTERIOR OPENINGS
 SHALL BE LIMITED TO THOSE NECESSARY FOR EXIT ACCESS TO
 THE ENCLOSURE FROM NORMALLY OCCUPIED SPACES AND FOR
 EGRESS FROM THE ENCLOSURE.
  
 7B) THE ELEVATOR MACHINE ROOM DOES NOT SHOW ANY FIRE
 RATING ON EITHER THE WALLS OR OPENING PROTECTION.
 PLEASE SHOW COMPLIANCE WITH FBC-B 3006.4.
  
 7C) THIS SHEET INDICATES THE FINISH FLOOR HEIGHT ABOVE
 GRAGE IS 29'-6" THE MEAN ROOF HEIGHT OF THE TOWER
 ENCLOSE IS GREATER THAN 33 FT. THE SUBMITTED ROOFING
 APPROVAL GAF TIMBERLINE ULTRA HD SHINGLES NOA
 13-1104.12 LIMITATION # 2 LIMITS THE INSTALATION OF
 THIS PRODUCT TO 33 FT. MEAN ROOF HEIGHT.THE TOP OF THE
 ELEVATOR SHAFT IS AT 38'-0".
  
 7D) PLEASE PROVIDE HOW THE A/C CONDENSATE ROOF TOP
 UNITS ARE GOING TO BE SECURED TO THE ROOF RACKS AND HOW
 THE ROOF RACKS ARE GOING TO BE SECURED TO THE CONCRETE
 ROOF DECK. PLEASE ALSO BE AWARE OF FBC-B TABLE 1509.7.
  
 7E) HOW WILL THE 3RD FLOOR UNITS BENEATH THE FLAT
 ROOFED AREA ACHIEVE THE R-19 VALUE REQUIRED BY THE
 ENERGY CODE AND SUMMARY REPORT SUBMITTED.
  
 8) THE PLANS DO NOT PROVIDE HOW COMPLIANCE WITH
 AIR-BORNE SOUND, SHEET 1A-7.02 DETAIL #4 SHOWS A PARTY
 WALL TYPE CONFIGURATION BUT NOT SHOWING COMPLIANCE WITH
 2010 FBC-B 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90. PENETRATIONS OR OPENINGS IN CONSTRUCTION
 ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED
 CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR
 EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED OR
 OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS.
 THIS REQUIREMENT SHALL NOT APPLY TO DWELLING UNIT
 ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT
 FITTING TO THE FRAME AND SILL.
  
 9) THE OTHER ISSUE THE PLANS DO NOT SHOW COMPLIANCE
 WITH IS 2010 FBC-B 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 10) PAGE 085 1A-7.01 WINDOW BUCK DETAIL # 4 IS ACTUALLY
 DRAWN WRONG, THE CODE SECTION DIRECTLY ABOVE IR STATES
 UNLESS OTHERWISE TWESTED BUCKS SHALL EXTEND BEYOND THE
 INTERIOR SURFACE OF THE WINDOE OR DOOR FRAME. FBC-B
 1715.5.4.2.
  
 11) PAGE 87 1A-7.03 DETAIL 3 INDICATES THE HAND RAIL @
 34 IN. A.F.F. PLEASE REVIEW FBC-B 1012.2 THE HEIGHT IS
 TO BE MEASURED FROM THE TREAD NOSING.
  
 12) THE PRESSURES FOR THE ROOF FLAT SECTION ARE GOOD,
 NO ROOF ZONE 3 THE PAARAPET IS AT LEAST 3'-0" HIGH
 ELIMINATING ZONE 3. WINDOW AND DOOR PRESSURES ARE GOOD
 FOR A MEAN ROOF HEIGHT OF 32.5 FT. THE ISSUE WILL BE
 THE ROOF LEVEL OF THE PENTHOUSE SINCE THE LOCATION IS
 ABOVE 33 FT, NO SHINGLES MAY BE PUT ON A ROOF WITH A
 MEAN ROOF HEIGTH OF 33 FT, SEE NOA LIMITATION. IF THE
 WHOLE ROOFING STYLE IS TO CHANGE FROM SHINGLES THEN
 PRESSURES FOR A 4/12 ROOF WILL BE NEEDED FOR BOTH A
 MEAN ROOF HEIGHT OF 32.5 FT AND PENTHOUSE AT APPROX
 41.0. FT.
  
 13) THE PRODUCT APPROVALS DO NOT HAVE TO BE SUBMITTED
 AT THIS TIME. AS LONG AS THE WIND DESIGN AND PRESSURES
 ARE CORRECT, THE PRODUCT APPROVALS CAN BE SUBMITTED
 AFTER PERMIT ISSUANCE AS A DEFERRED SUBMITTAL, NO COST
 TO CONTRACTOR. THERE IS NO CONTRACTOR SIGNED ON, THEY
 THEN BID THE JOBS OUT, THE PRODUCT APPROVALS SUBMITTED
 TODAY MAY NOT BE WHAT IS ACTUAL SUBMITTED TO BE BUILT.
 IF THE DESIGNER OF RECORD WOULD PREFER TO HAVE THE
 PRODUCT APPROVALS DEFERRRED IN THE RESPONCE JUST NOTE
 SO.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2 DEFERRED
 SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, DEFERRED
 SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF THE DESIGN
 THAT ARE NOT SUBMITTED AT THE TIME OF THE APPLICATION
 AND THAT ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL
 WITHIN A SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL
 ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING
 OFFICIAL. THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE SHALL LIST THE DEFERRED SUBMITTALS
 ON THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE
 BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED SUBMITTAL
 ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL REVIEW
 THEM AND FORWARD THEM TO THE
 BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND
 FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE
 BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE
 INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN APPROVED BY THE BUILDING OFFICIAL.
  
 13A) NOA 12-0320.07 SUNSHINE 2000 SERIES SINGLE HUNG,
 LMI PLEASE CIRCLE THE UNITS HEIGHT, WIDTH, PRESSURES &
 ANCHORAGE.
  
 13B) NOA 13-0122.05 SUNSHINE 8000 SERIES STOREFRONT,
 LMI PLEASE CIRCLE THE UNITS HEIGHT, WIDTH, PRESSURES &
 ANCHORAGE.
  
 13C) NOA 11-1216.02 SUNSHINE MULLION CIRCLE WIDTH,
 SPAN, MULLION SIZE PRESSURES AND TYPE OF ANCHORS.
  
 13D) NOA 14-0109.06 SUNSHINE ALUMINUM, OUTSWING FRENCH
 DOORS NOTE FLUSHBOLTS WILL NEED TO WORK FROM A WHEEL
 CHAIR POSITION, PLEASE CIRCLE THE UNITS HEIGHT, WIDTH,
 PRESSURES & ANCHORAGE.
  
 13E) FL. 14237-R1 FLEMING BARON CIRCLE IF SINGLE OR
 PAIR, INSWEING OR OUT, TYPE OF LATCH ANCHORAGE AND
 ASSOCIATED PRESSURES.
  
 13F) JOHN MANSVILLE TPO SINGLE PLY ROOFING OVER
 LIGHTWEIGHT CONCRETE DECK. NOA 14-0618.05 CIRCLE WHICH
 SUB-SYSTEM TO BE INSTALLED AND ASSOCIATED PRESSURES.
  
 13G) NOA 13-1104.12 GAF TIMBERLINE ULTRA HD
 SHINGLESNOTE THIS PRODUCT UNDER LIMITATIONS IS NOT TO
 BE INSTALLED ABOVE 33 FT. THE PENTHOUSE ROOF IS WELL
 ABOVE THE 33 FT MEAN ROOF HEIGHT.
  
 13H) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE
 PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03
 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 14A) THE ENERGY CALCULATIONS INDICATE A VENTED ATTIC
 AND R-19 INSULATION, LOCATED WHERE?
  
 14B) ROOF VENTILATION PAGE 049, 1A-0.40 THE PLANS
 INDICATE THE USE OF SOFFIT VENTILATION BUT DO NOT
 INDICATE COMPLIANCE WITH FBC-B 1203.2 50 PERCENT OF THE
 REQUIRED VENTILATING AREA PROVIDED BY VENTILATORS
 LOCATED IN THE UPPER PORTION OF THE SPACE TO BE
 VENTILATED AT LEAST 3 FEET (914 MM) ABOVE EAVE OR
 CORNICE VENTS WITH THE BALANCE OF THE REQUIRED
 VENTILATION PROVIDED BY EAVE OR CORNICE VENTS.
  
 15) THE ENERGY CALCULATIONS WILL NEED TO REFLECT THE
 VALUES FOR A1 END UNIT, B UNIT INTERIOR AS WELL AS A
 END UNIT, AND A A2 INTERIOR UNIT, ALL ON GRADE, THEN
 FOR 2ND FLOOR SUROUNDED ABOVE AND BELOW WITH A/C AND
 THE 3RD FLOOR UNITS WITH ROOF INSULATION OVERHEAD.
  
 16) PLEASE PROVIDE THE WINDOW AND DOOR SHGC OF 0.5
 FBC-ENERGY 402.3.
  
 17) LIFE SAFETY SHEETS TO SHOW AREA OF RESCUE
 ASSISTANCE 2010 FBC-ACCESSIBILITY CODE 207.1. SEE
 SECTION 1007 OF THE 2003 IBC 107.6 AREA OF REFUGE.
  
 18) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 19) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2015-03-10 Cont ID  
Sent By dhayes Date 2015-03-10 Time 16:29 Rev Time 0.00
Received By dhayes Date 2015-03-10 Time 07:33 Sent To  
Notes
2015-03-10 16:34:373/10/2015
 PROJECT: GRANT ST
 PERMIT#: 14120686
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 2ND ELECTRICAL PLAN REVIEW
 ACTION: APPROVED WITH EXCEPTION
  
 SHEET ES1.1
 CLARIFY THE NOTES BY THE TRASH COMPACTOR. ONE NOTE
 CALLS FOR A 30AMP DISCONNECT FUSED AT 20AMPS. AND THE
 SECOND CALLS FOR A 100AMP DISCONNECT FUSED AT 60AMP.
 THERE IS ONLY REFERENCE TO ONE CIRCUIT NUMBER IN PANEL
 H1. IS THERE ANOTHER CIRCUIT REQUIRED?
  
 SHEET E1.1B
 PROVIDE NORMAL AND EMERGENCY LIGHTING FOR STAIRWAY #1,
 AT 1ST AND SND FL LANDING. NEC 700.16
  
 SHEET E1.1C
 A) REVISE THE GFI RECEPTACLE SYMBOL INDICATED BY THE
 KITCHEN SINK. ONE OF THE GFI OUTLETS IS INDICATED AS AN
 ABOVE COUNTER RECEPTACLE AND THE OTHER IS NOT. ARE BOTH
 RECEPTACLES PROPOSED TO BE INSTALLED AT THE COUNTERTOP
 ELEVATION? REVISE ACCORDINGLY.
 B) ONLY A MICROWAVE AND REFRIGERATOR OUTLET ARE SHOWN.
 ARE ANY ADDITIONAL OUTLETS PROPOSED FOR THE COUNTERTOP
 ELEVATION?
  
 SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY
 MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS
 PLANS AND ENGINEERING ARE REQUIRED FOR SITE LIGHTING,
 GENERATORS. FIRE ALARM, ACCESS CONTROL SYSTEM,
 SECURITY, CCTV, AUDIO/VIDEO, NETWORK, DATA, AND,
 COMMUNICATION.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2015-01-23 Cont ID  
Sent By dhayes Date 2015-01-23 Time 12:52 Rev Time 0.00
Received By dhayes Date 2015-01-22 Time 15:58 Sent To  
Notes
2015-01-23 10:38:321/23/2015
 PROJECT: 50 MULTIFAMILY UNITS
 PERMIT#: 14120686
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 CLARIFICATION REQUIRED. WPB AMENDMENTS TO FBC 107.3.
 PLEASE REVISE THE RISER AND/OR PANEL SCHEDULE FOR PANEL
 MDP.SEE NOTES BELOW FOR CLARIFICATION:
  
 1) THE RISER INDICATES A 200AMP DISCONNECT FUSED AT
 150AMPS FOR THE ELEVATOR CONTROL CIRCUIT, AND THE PANEL
 SCHEDULE CALLS FOR A 125AMP BREAKER FEEDING THIS
 CIRCUIT.
  
 2) THE RISER INDICATES NOTE 4, A 3/0 FEEDER FEEDING
 PANEL H1AND THE PANEL SCHEDULE CALLS FOR A 250AMP
 BREAKER WITH A 250MCM FEEDER FOR THIS CIRCUIT.
  
 3) ADD A FEEDER SCHEDULE KEY NOTE FOR THE FEEDER FROM
 MDP TO THE ELEVATOR CONTROL DISCONNECT..
  
 4) THE RISER INDICATE A 3POLE 30AMP DISCONNECT FUSED AT
 20AMP FOR ELEVATOR CAB LIGHTS BUT THE PANEL SCHEDULE IN
 MDP CALLS FOR A 2POLE 20AMP BREAKER FEEDING THIS
 CIRCUIT.
  
 5) ADD A FEEDER SCHEDULE KEY NOTE FOR THE FEEDER FROM
 MDP TO THE ELEVATOR CAB LIGHTS.
  
 SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY
 MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS
 ARE REQUIRED FOR SITE LIGHTING, GENERATORS. HOOD
 EXHAUST, FIRE ALARM, ACCESS CONTROL SYSTEM, SECURITY,
 CCTV, NETWORK, DATA, AND, COMMUNICATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED
 PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE
 PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE
 REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2015-06-17 Cont ID  
Sent By Mgonzale Date 2015-06-17 Time   Rev Time 1.00
Received By mgonzale Date 2015-06-17 Time   Sent To I
Notes
2015-06-17 17:43:34PROVISOS:
  
 ENGINEERING REVIEW IS STILL PENDING UNTIL PROJECT
 CLEARS PBCHD AND FDEP PERMITTING.
  
 STORM WATER PROVISOS MAY COME AS PART OF ENGINEERING
 REVIEW.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2015-04-15 Cont ID  
Sent By cranford Date 2015-04-15 Time 08:36 Rev Time 0.00
Received By cranford Date 2015-04-15 Time 08:36 Sent To  
Notes
2015-04-15 08:36:173RD REVIEW
  
 SEE COMMENTS UNDER 2ND REVIEW. NO REVISIONS HAVE BEEN
 MADE TO CIVIL PLANS.
  
 KELLY CRANFORD, P.E.
 LAND DEVELOPMENT ENGINEER
 PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2015-03-11 Cont ID  
Sent By cranford Date 2015-03-11 Time 11:41 Rev Time 0.00
Received By cranford Date 2015-03-11 Time 11:40 Sent To  
Notes
2015-03-11 11:41:14PLEASE SEE COMMENTS UNDER APPLICATION 14120680.
  
 KELLY CRANFORD, PE
 CITY LAND DEVELOPMENT ENGINEER
 (561)494-1098
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2015-01-02 Cont ID  
Sent By cranford Date 2015-01-02 Time 15:44 Rev Time 0.00
Received By cranford Date 2015-01-02 Time 15:43 Sent To  
Notes
2015-01-02 15:44:05PLEASE SUBMIT APPLICATIONS FOR A DEVELOPMENT PERMIT AND
 RIGHT-OF-WAY PERMIT FROM THE ENGINEERING DEPARTMENT.
 APPLICATION FORMS CAN BE FOUND AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
 (SECTIONS 2-421 AND 78-432, CODE OF ORDINANCES)
  
 ALSO SEE COMMENTS UNDER APPLICATION 14120680

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2015-04-28 Cont ID  
Sent By wjolin Date 2015-04-28 Time 15:12 Rev Time 0.00
Received By wjolin Date 2015-04-28 Time 14:53 Sent To  
Notes
2015-04-28 15:12:03906 GRANT STREET - BUILDING #2: 50 UNIT APARTMENT
 PERMIT #14120686
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 RESPONSE COMMENT: THE BACKFLOW PREVENTION DEVICES
 (SHUTOFF VALVES) NEED TO BE LOCATED A SAFE DISTANCE
 FROM THE BUILDING TO AVOID FIREFIGHTER INJURIES DUE TO
 FALLING GLASS, COLLAPSING WALLS, FALLING DEBRIS, ETC.
 ORIGINAL COMMENT: SHEET PWS-1: PER NFPA 24 SECTION
 6.2.1, ALL CONNECTIONS TO PRIVATE FIRE SERVICE MAINS
 FOR FIRE PROTECTION SYSTEMS SHALL BE ARRANGED IN
 ACCORDANCE WITH ONE OF THE FOLLOWING SO THAT THEY CAN
 BE ISOLATED:
 (1) A POST INDICATOR VALVE INSTALLED NOT LESS THAN 40
 FEET FROM THE BUILDING.
 (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A POST
 INDICATOR VALVE SHALL BE PERMITTED TO BE INSTALLED
 CLOSER THAN 40 FEET BUT AT LEAST AS FAR FROM THE
 BUILDING AS THE HEIGHT OF THE WALL FACING THE POST
 INDICATOR VALVE.
 (2) A WALL POST INDICATOR VALVE
 (3) AN INDICATING VALVE IN A PIT, INSTALLED IN
 ACCORDANCE WITH SECTION 6.4
 (4) A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING
 VALVE NOT LESS THAN 40 FEET FROM THE BUILDING.
 (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A
 BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING VALVE
 SHALL BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FEET
 BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF
 THE WALL FACING THE BACKFLOW PREVENTER.
 (5) CONTROL VALVES INSTALLED IN A FIRE-RATED ROOM
 ACCESSIBLE FROM THE EXTERIOR
 (6) CONTROL VALVES IN A FIRE-RATED STAIR ENCLOSURE
 ACCESSIBLE FROM THE EXTERIOR AS PERMITTED BY THE
 AUTHORITY HAVING JURISDICTION
  
 FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT ISSUED
 SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE
 WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR
 SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES,
 NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING
 OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF
 ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS
 CODE. REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE
 THE OWNER, CONTRACTOR, ETC. OF THE RESPONSIBILITY OF
 COMPLIANCE WITH CODE (NFPA 1, SECTION 1.14.4).
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2015-03-06 Cont ID  
Sent By wjolin Date 2015-03-06 Time 10:07 Rev Time 0.00
Received By wjolin Date 2015-03-06 Time 10:05 Sent To  
Notes
2015-03-06 10:05:34906 GRANT STREET - BUILDING #2: 50 UNIT APARTMENT
 PERMIT #14120686
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 RESPONSE COMMENT: THE BACKFLOW PREVENTION DEVICES
 (SHUTOFF VALVES) NEED TO BE LOCATED A SAFE DISTANCE
 FROM THE BUILDING TO AVOID FIREFIGHTER INJURIES DUE TO
 FALLING GLASS, COLLAPSING WALLS, FALLING DEBRIS, ETC.
 ORIGINAL COMMENT: SHEET PWS-1: PER NFPA 24 SECTION
 6.2.1, ALL CONNECTIONS TO PRIVATE FIRE SERVICE MAINS
 FOR FIRE PROTECTION SYSTEMS SHALL BE ARRANGED IN
 ACCORDANCE WITH ONE OF THE FOLLOWING SO THAT THEY CAN
 BE ISOLATED:
 (1) A POST INDICATOR VALVE INSTALLED NOT LESS THAN 40
 FEET FROM THE BUILDING.
 (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A POST
 INDICATOR VALVE SHALL BE PERMITTED TO BE INSTALLED
 CLOSER THAN 40 FEET BUT AT LEAST AS FAR FROM THE
 BUILDING AS THE HEIGHT OF THE WALL FACING THE POST
 INDICATOR VALVE.
 (2) A WALL POST INDICATOR VALVE
 (3) AN INDICATING VALVE IN A PIT, INSTALLED IN
 ACCORDANCE WITH SECTION 6.4
 (4) A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING
 VALVE NOT LESS THAN 40 FEET FROM THE BUILDING.
 (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A
 BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING VALVE
 SHALL BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FEET
 BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF
 THE WALL FACING THE BACKFLOW PREVENTER.
 (5) CONTROL VALVES INSTALLED IN A FIRE-RATED ROOM
 ACCESSIBLE FROM THE EXTERIOR
 (6) CONTROL VALVES IN A FIRE-RATED STAIR ENCLOSURE
 ACCESSIBLE FROM THE EXTERIOR AS PERMITTED BY THE
 AUTHORITY HAVING JURISDICTION
  
 REPEAT COMMENT - SHEET 1A-1.04 & 1A-9.01: THE CENTER
 STAIR APPEARS TO BE COMPLETELY ENCLOSED (WALLS AND
 ROOF) AND COULD RESULT IN AN ACCUMULATION OF SMOKE IN A
 FIRE EVENT. THE STAIR NEEDS TO BE OPEN OR WOULD NEED TO
 BE PROTECTED AS AN ENCLOSED STAIR WITH FIRE RATED
 CONSTRUCTION, PROTECTED OPENINGS/PENETRATIONS AND NOT
 BE OPEN TO OTHER COMBUSTIBLES SUCH AS THE ELEVATOR
 CONTROL CLOSET.
  
 FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT ISSUED
 SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE
 WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR
 SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES,
 NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING
 OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF
 ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS
 CODE. REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE
 THE OWNER, CONTRACTOR, ETC. OF THE RESPONSIBILITY OF
 COMPLIANCE WITH CODE (NFPA 1, SECTION 1.14.4).
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2015-02-10 Cont ID  
Sent By wjolin Date 2015-02-10 Time 14:18 Rev Time 0.00
Received By wjolin Date 2015-02-06 Time 15:05 Sent To  
Notes
2015-02-10 07:21:43906 GRANT STREET - BUILDING #2: 50 UNIT APARTMENT
 PERMIT #14120686
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 GENERAL: PER NFPA 241 SECTION 8.7.2.3, WHERE
 UNDERGROUND WATER MAINS AND HYDRANTS ARE TO BE
 PROVIDED, THEY SHALL BE INSTALLED, COMPLETED, AND IN
 SERVICE PRIOR TO CONSTRUCTION WORK.
  
 GENERAL: PROVIDE DRAWING NOTE INDICATING ALL
 CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO THE
 REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION DEBRIS
 SHALL BE REMOVED FROM THE SITE DAILY. SMOKING SHALL BE
 PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL
 OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE
 RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED.
  
 GENERAL: INDICATE IF ANY TEMPORARY CONSTRUCTION
 TRAILERS ARE INTEDED TO OCCUPY THE SITE: PER NFPA 241
 SECTION 4.2.2: DETACHMENT BETWEEN TEMPORARY STRUCTURES,
 ADEQUATE TEMPORARY FIXED FIRE PROTECTION SYSTEMS, AND
 PORTABLE EQUIPMENT SHALL BE PROVIDED AS REQUIRED BY THE
 AUTHORITY HAVING JURISDICTION.
 PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION,
 ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2:
 TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF
 COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE
 CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS,
 TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1.
 PER TABLE 4.2.1:
 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 30 FEET
 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 35 FEET
 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 40 FEET
 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 45 FEET
 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 50 FEET
 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE
 SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET
 **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL
 BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC
 SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE.
  
 SHEET PWS-1: BOTH FIRE DEPARTMENT CONNECTIONS ARE
 LOCATED IN PARKING ISLANDS WITH PARKING SPACES ON BOTH
 SIDES. PER FFPC (NFPA 1) SECTION 18.3.4.2, FIRE
 HYDRANTS AND FIRE PROTECTION APPLIANCES SHALL BE
 PROVIDED WITH CLEARANCES OF 7'-6" TO THE FRONT AND
 SIDES OF THE APPLIANCE.
  
 SHEET PWS-1: PER NFPA 24 SECTION 6.2.1, ALL CONNECTIONS
 TO PRIVATE FIRE SERVICE MAINS FOR FIRE PROTECTION
 SYSTEMS SHALL BE ARRANGED IN ACCORDANCE WITH ONE OF THE
 FOLLOWING SO THAT THEY CAN BE ISOLATED:
 (1) A POST INDICATOR VALVE INSTALLED NOT LESS THAN 40
 FEET FROM THE BUILDING.
 (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A POST
 INDICATOR VALVE SHALL BE PERMITTED TO BE INSTALLED
 CLOSER THAN 40 FEET BUT AT LEAST AS FAR FROM THE
 BUILDING AS THE HEIGHT OF THE WALL FACING THE POST
 INDICATOR VALVE.
 (2) A WALL POST INDICATOR VALVE
 (3) AN INDICATING VALVE IN A PIT, INSTALLED IN
 ACCORDANCE WITH SECTION 6.4
 (4) A BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING
 VALVE NOT LESS THAN 40 FEET FROM THE BUILDING.
 (A) FOR BUILDINGS LESS THAN 40 FEET IN HEIGHT, A
 BACKFLOW PREVENTER WITH AT LEAST ONE INDICATING VALVE
 SHALL BE PERMITTED TO BE INSTALLED CLOSER THAN 40 FEET
 BUT AT LEAST AS FAR FROM THE BUILDING AS THE HEIGHT OF
 THE WALL FACING THE BACKFLOW PREVENTER.
 (5) CONTROL VALVES INSTALLED IN A FIRE-RATED ROOM
 ACCESSIBLE FROM THE EXTERIOR
 (6) CONTROL VALVES IN A FIRE-RATED STAIR ENCLOSURE
 ACCESSIBLE FROM THE EXTERIOR AS PERMITTED BY THE
 AUTHORITY HAVING JURISDICTION
  
 SHEET PWS-1: PROVIDE CHAIN WITH LOCK AND TAMPER
 SWITCHES FOR SUPERVISING THE BACKFLOW PREVENTER IN THE
 OPEN POSITION. PROVIDE LOCKING KNOX CAPS ON FIRE
 DEPARTMENT CONNECTION.
  
 SHEET LP-2: TWO GREEN BUTTONWOOD TREES ARE LOCATED IN
 THE PARKING ISLANDS HOUSING THE FIRE DEPARTMENT
 CONNECTIONS. PER FFPC (NFPA 1) SECTION 18.3.4.2, FIRE
 HYDRANTS AND FIRE PROTECTION APPLIANCES SHALL BE
 PROVIDED WITH CLEARANCES OF 7'-6" TO THE FRONT AND
 SIDES OF THE APPLIANCE.
  
 SHEET A-0.01: THE TURNING RADIUS APPEARS TO BE TOO
 SMALL TO ACCOMODATE A 47'-0" LONG LADDER TRUCK FOR THE
 PARKING LOT ACCESS ROAD DIRECTLY SOUTH OF THE CLUBHOUSE
 (NOT THE DROP-OFF AREA).
  
 SHEET 1A-1.04 & 1A-9.01: THE CENTER STAIR APPEARS TO BE
 COMPLETELY ENCLOSED (WALLS AND ROOF) AND COULD RESULT
 IN AN ACCUMULATION OF SMOKE IN A FIRE EVENT. THE STAIR
 NEEDS TO BE OPEN OR WOULD NEED TO BE PROTECTED AS AN
 ENCLOSED STAIR WITH FIRE RATED CONSTRUCTION, PROTECTED
 OPENINGS/PENETRATIONS AND NOT BE OPEN TO OTHER
 COMBUSTIBLES SUCH AS THE ELEVATOR CONTROL CLOSET.
  
 SHEET 1A-1.04: CONFIRM THE ELEVATOR CONTROL CLOSET DOES
 NOT NEED A FIRE RESISTANCE RATING WITH PROTECTED
 OPENINGS.
  
 SHEET E.01: CONFIRM LIGHTING FIXTURE TYPE C PROVIDING
 STAIR ILLUMINATION ALSO PROVIDES EMERGENCY LIGHTING.
  
 SHEET E5.1: FIRE ALARM CONTROL PANEL APPEARS TO BE
 LOCATED BEHIND THE ELECTRICAL ROOM ENTRANCE DOOR.
  
 SHEET ER1.1A: COULD NOT LOCATE LIGHTING OR EMERGENCY
 LIGHTING IN THE CENTER STAIR ENCLOSURE ON THE ROOF
 LEVEL.
  
 SHEET FA0.1: FIRE ALARM SYSTEM SHALL BE ADDRESSABLE.
 PROVIDE TAMPER SWITCHES FOR SUPERVISING THE BACKFLOW
 PREVENTER IN THE OPEN POSITION.
  
 SHEET FA1.1A: FIRE ALARM CONTROL PANEL APPEARS TO BE
 LOCATED BEHIND THE ELECTRICAL ROOM ENTRANCE DOOR.
  
 SHEET FA1.1A: COULD NOT LOCATE ANY MANUAL PULL STATIONS
 ON 1ST FLOOR.
  
 SHEET FA1.1A: NOTIFICATION MISSING FROM ACTIVITY ROOMS
 AND RESTROOMS.
  
 FIRE ALARM ROOF LEVEL: NO NOTIFICATION PROVIDED IN
 CENTER STAIR/ROOF LEVEL.
  
 SHEET FPS.1 & PWS-1: FIRE AND CIVIL DESIGN IS NOT AT
 ALL COORDINATED. PLANS ALSO SHOW AN FDC AT THE
 CLUBHOUSE; HOWEVER, THE CLUBHOUSE PERMIT DOES NOT
 INDICATE THIS BUILDING IS SPRINKLERED.
  
 FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT ISSUED
 SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED WITH THE
 WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR
 SET ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES,
 NOR SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING
 OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF
 ERRORS IN PLANS, CONSTRUCTION OR VIOLATIONS OF THIS
 CODE. REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE
 THE OWNER, CONTRACTOR, ETC. OF THE RESPONSIBILITY OF
 COMPLIANCE WITH CODE (NFPA 1, SECTION 1.14.4).
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-08-10 Cont ID  
Sent By cpuell Date 2015-08-10 Time 11:52 Rev Time 0.00
Received By cpuell Date 2015-06-11 Time 15:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-04-29 Cont ID  
Sent By lmarchan Date 2015-04-29 Time 08:48 Rev Time 0.00
Received By lmarchan Date 2015-04-07 Time 08:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-04-02 Cont ID  
Sent By lmarchan Date 2015-04-02 Time 13:07 Rev Time 0.00
Received By lmarchan Date 2015-02-26 Time 11:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-02-10 Cont ID  
Sent By cpuell Date 2015-02-10 Time 14:54 Rev Time 0.00
Received By cpuell Date 2014-12-23 Time 14:56 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2015-09-08 Cont ID  
Sent By skennedy Date 2015-09-08 Time 16:08 Rev Time 0.00
Received By skennedy Date 2015-09-08 Time 16:08 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2015-04-09 Cont ID  
Sent By jwitmer Date 2015-04-09 Time 15:48 Rev Time 0.00
Received By jwitmer Date 2015-04-09 Time 15:48 Sent To  
Notes
2015-04-09 15:49:13IMPACT FEES
 BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2015-03-09 Cont ID  
Sent By jwitmer Date 2015-03-09 Time 07:04 Rev Time 0.00
Received By jwitmer Date 2015-03-09 Time 07:04 Sent To  
Notes
2015-03-09 07:04:16BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2015-01-13 Cont ID  
Sent By jwitmer Date 2015-01-13 Time 06:38 Rev Time 0.00
Received By jwitmer Date 2015-01-13 Time 06:37 Sent To  
Notes
2015-01-13 06:37:52BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2015-03-17 Cont ID  
Sent By hmoser Date 2015-03-17 Time 10:29 Rev Time 0.00
Received By hmoser Date 2015-03-16 Time 13:47 Sent To  
Notes
2015-03-17 10:28:57PASS PROVISO
 1) REFER TO SECTION 304.1 GENERAL. PROVIDE
 MANUFACTURER'S INSTALLATION INSTRUCTIONS
 FOR CLOTHES DRYERS ON JOB SITE AT TIME OF INSPECTION
 2010 FBC (M)
 2) IF AIR CONDITIONING CLOSET DOORS ARE PAINTED WITH
 INTUMESCENT PAINT NONCOMBUSTIBLE
 LABELS MUST BE ON THE INSIDE OF THE DOOR STATING TYPE
 OF PAINT USED AND ONLY THIS PANT
 CAN BE USED TO PAINT THE DOOR.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-01-20 Cont ID  
Sent By hmoser Date 2015-01-20 Time 14:51 Rev Time 0.00
Received By hmoser Date 2015-01-20 Time 13:15 Sent To  
Notes
2015-01-20 14:51:33PLAN DENIED
 1) PROVIDE DUCT SIZE ON ALL SUPPLY AND RETURN AIR DUCT
 PER SECTION 107 FBC 2010
 2) ACTIVITY ROOM REFER TO SECTION 602.2.1 MATERIALS
 WITHIN PLENUM'S
 2010 FBC (M)
 3) ELECTRICAL ROOM EXHAUST. REFER TO SECTION 501.2
 EXHAUST DISCHARGE
 2010 FBC (M)
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 3 Status P Date 2015-04-29 Cont ID  
Sent By tklarge Date 2015-04-29 Time 07:50 Rev Time 0.00
Received By tklarge Date 2015-04-29 Time 06:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2015-03-20 Cont ID  
Sent By tklarge Date 2015-03-20 Time 06:47 Rev Time 0.00
Received By tklarge Date 2015-03-19 Time 12:16 Sent To  
Notes
2015-03-19 12:36:181) ADDITIONAL INFORMATION SHALL BE PROVIDED FOR THE
 ROOF DRAINAGE CALCULATIONS.SHOW THE LENGTH AND HEIGHT
 OF THE PARAPET WALL THAT ENCOMPASSES THE FLAT ROOF
 AREAS ON BOTH BUILDINGS. ALSO, SHOW THE LENGTH AND
 WIDTH OF THE FLAT ROOF AREAS IN ORDER TO CHECK THE
 SQUARE FOOTAGE OF THE ROOF BEING DRAINED BY EACH ROOF
 DRAIN.WPB AMEND. TO 2010 FBC SEC.107.2.1.
 2) ONE HALF THE AREA OF THE VERTICAL WALLS OF THE
 STAIRWELLS THAT ARE LOCATED INSIDE THE PARAPET WALL
 SHALL ALSO BE ADDED INTO THE TOTAL SQUARE FOOTAGE BEING
 DRAINED BY THE ROOF DRAINAGE SYSTEM. 2010 FPC
 SEC.1106.4.
 3) THERE ARE SECTIONS OF THE STAIRWELL ROOFS THAT DRAIN
 ONTO THE FLAT ROOF. THIS MUST ALSO BE ADDED INTO THE
 ROOF DRAINAGE CALCULATIONS. 2010 FPC SEC.1106.3.
 4) INDICATE THE HEIGHT OF THE PARAPET WALL ON THE
 PLANS. IT APPEARS TO BE 4'-6" IN HEIGHT. CLARIFY.WPB
 AMEND.TO 2010 FBC SEC. 107.2.1.
 5) SHT. 1A-1.05B - ITEM #17B - ALL HAND HELD SHOWER
 SPRAYS SHALL BE EQUIPPED WITH BACKFLOW PREVENTION
 DEVICES PER THE 2010 FPC SEC.424.2.
 6) THE RAIN GUTTERS FOR THE BUILDING SHALL BE SIZED IN
 ACCORDANCE WITH TABLE 1106.6. OF THE 2010 FPC. SUBMIT
 CALCULATIONS FOR THE GUTTER SIZING AND THE SLOPE AT
 WHICH THE GUTTERS WILL BE INSTALLED.
 7) SHT.P2.3 - ELEVATOR SUMP DETAIL - THE SIZE OF THE
 SUMP PIT SHALL BE A MINIMUM OF 24 INCHES DEEP PER THE
 2010 FPC SEC.1113.1.2, 712.3.2. THERE IS ANOTHER DETAIL
 ON SHT. S-5.2. IN THE PLANS THAT NEEDS TO BE CORRECTED.
  
 FIRE PROTECTION
  
 6) SHOW THE SIZE OF THE FIRE DEPARTMENT CONNECTION ON
 THE PLAN. THE AREA ON THE PLAN IS CLOUDED BUT THERE IS
 NO SIZE SHOWN. THE MINIMUM SIZE FDC SHALL BE 1 1/2 "
 PER NFPA 13R SEC.6.6.4.2.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-01-04 Cont ID  
Sent By tklarge Date 2015-01-04 Time 07:12 Rev Time 0.00
Received By tklarge Date 2015-01-04 Time 02:42 Sent To  
Notes
2015-01-04 04:19:191) SUBMIT ROOF DRAINAGE CALCULATION FOR 1/2 THE AREA OF
 THE PARAPET WALL THAT IS TO BE INCLUDED WHEN SIZING THE
 ROOF DRAINAGE SYSTEM.
 2010 FL. PLBG. CODE SEC. 1106.4 VERTICAL WALLS.
 IN SIZING ROOF DRAINS AND STORM DRAINAGE PIPING,
 ONE-HALF OF THE AREA OF ANY VERTICAL WALL THAT DIVERTS
 RAINWATER TO THE ROOF SHALL BE ADDED TO THE PROJECTED
 ROOF AREA FOR INCLUSION IN CALCULATING THE REQUIRED
 SIZE OF VERTICAL CONDUCTORS, LEADERS AND HORIZONTAL
 STORM DRAINAGE PIPING.
 2) SHT. 1A-5.30 - DETAILS #1-3 - THE ELEVATIONS APPEAR
 TO SHOW CONFLICTING HEIGHT DETAILS FOR THE WATER CLOSET
 FROM THE FINISH FLOOR TO THE TOP OF THE WATER CLOSET
 SEAT. ONE VIEW SHOWS THE DISTANCE AS 17-19 INCHES TO
 THE TOP OF SEAT AND THE OTHER ELEVATION APPEARS TO SHOW
 THE HEIGHT TO THE TOP OF THE WATER CLOSET. CLARIFY.
 COMPLY WITH 2010 FAC SEC.604.4. REVIEW ELEVATIONS 2 A &
 2B & 3A & 3B.
 3) SHT. P1.1A & P1.1B - SHOW SUMP DISCHARGE PIPING FOR
 THE ELEVATIOR SHAFT. SUBMIT A DETAIL SHOWING THE PUMP
 AND ALL ASSOCIATED PIPING. WPB AMEND. TO 2010 FBC
 SEC.107.2.1.
 4) FLOOR DRAINS ARE SHOWN IN THE LOBBY AREA BUT ARE NOT
 SHOWN ON THE SANITARY RISER. CLARIFY. FLOOR DRAINS
 SHALL BE EQUIPPED WITH TRAP PRIMERS PER THE 2010 FPC
 SEC.1002.4.
 5) A WELL PERMIT WILL BE REQUIRED FROM THE PALM BEACH
 COUNTY HEALTH DEPT. FOR THE IRRIGATION WELL.
 6) SHT.S-1.1 REFERS TO SHT.S-5.1 FOR THE ELEVATOR PIT
 DETAIL. THERE IS NO ELEVATOR PIT DETAIL ON SHT.S-5.1.
 THE DETAIL IS ON SHT. S-5.2. REVISE THE NOTE TO
 REFERENCE THE CORRECT SHEET.
  
 FIRE PROTECTION
  
 1) JOB SPECIFICATION 211313 - PART 3- SEC. 3.4 (B)
 STATES THAT THE INSTALLATION OF THE SPRINKLER SYSTEM
 SHALL COMPLY WITH NFPA 13 BUT THE PLANS ARE FOR A 13R
 SYSTEM. CLARIFY.
 2) SHOW THE SIZE OF THE FDC LINE ON SHT.FPS.1.
 3) THE FIRE PROTECTION PLANS REFER TO THE 2007 EDITION
 OF NFPA 13R YET THE DESIGN AREA BOXES ON SHTS.FP2.2 &
 FP3.2 REFER TO THE 2010 EDITION. CLARIFY.
 4) CLEARLY IDENTIFY THE UNIT ON THE PLANS WHERE THE
 DESIGN AREAS ARE LOCATED. THE UNIT IS NOT IDENTIFIED ON
 THE PLANS ALTHOUGH THE UNIT NUMBER IS GIVEN.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2015-08-11 Cont ID  
Sent By skennedy Date 2015-08-11 Time 09:47 Rev Time 0.00
Received By skennedy Date 2015-08-10 Time 13:33 Sent To  
Notes
2015-06-26 09:43:13PEDDS SUBMITTED, WAITING ON PLAN REVIEW TO BE COMPLETE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2015-02-27 Cont ID  
Sent By cpuell Date 2015-02-27 Time 16:46 Rev Time 0.00
Received By cpuell Date 2015-02-27 Time 16:46 Sent To  
Notes
2015-02-27 16:46:14SOIL TEST REPORT SUBMITTED IN PAPER SIGNED & SEALED
 UPLOADED DOCUMENTS TO BE REVIEWED. CP

Review Stop Z ZONING
Rev No 3 Status P Date 2015-04-09 Cont ID  
Sent By ajones Date 2015-04-09 Time 17:54 Rev Time 0.00
Received By ajones Date 2015-04-09 Time 17:54 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2015-04-02 Cont ID  
Sent By ajonesva Date 2015-04-02 Time 12:41 Rev Time 0.00
Received By ajones Date 2015-04-02 Time 12:41 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-01-13 Cont ID  
Sent By avann Date 2015-01-13 Time 15:23 Rev Time 0.00
Received By ajones Date 2015-01-13 Time 15:23 Sent To  
Notes
2015-01-13 15:24:281/13/15- FAILED. 1. SITE PLAN DOES NOT MATCH APPROVED
 SITE PLAN.
 2. NEED TO UNDERSTAND THE ARCHITECTURE OF THE BUILDING.
 APPEARS TO BE DIFFERENT FROM THE CONCEPTUAL DRAWINGS
 THE COMMISSION SAW AND APPROVED.
 3. SEPERATE LANDSCAPE PERMIT REQUIRED.
  
 ANGELLA VANN, PLANNING AND ZONING ADMINISTRATOR
 561-822-1441
 [email protected]
  