Plan Review Details - Permit 14120672
| Plan Review Stops For Permit 14120672 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-03-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-03-17 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-03-16 |
Time |
10:31 |
Sent To |
M |
|
| Notes |
| 2015-03-16 10:36:03 | PROVISO - ADJUST VALUE TO INCLUDE MECHANICAL PRIOR TO | | | ISSUANCE | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-01-20 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-20 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2015-01-20 10:25:45 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FROM PREVIOUS LIST: | | | | | | 1. PROVIDE DOOR PRODUCT APPROVALS, FBC 107, FBC 2010 | | | RESIDENTIAL 301 (MULLION NOA SUBMITTED, AS WELL AS | | | ANOTHER SHUTTER PRODUCT APPROVAL, BUT NO DOOR PRODUCT | | | APPROVAL WAS PROVIDED). | | | | | | 2- 3. OK | | | | | | 4. FOR THE IMPACT PROTECTION, COMPLETE THE SAMPLE | | | INSTALLATION SCHEDULE OR PROVIDE ALL INFORMATION TO | | | SHOW CODE COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC | | | R301, FBC1609. TWO SETS REQUIRED. THIS FORM IS | | | AVAILABLE IN THE LOBBY OR ON THE INTERNET AT | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | | | 2ND REVIEW - INSTALLATION SCHEDULE SUBMITTED IS | | | INCOMPLETE. | | | | | | TWO DIFFERENT PRODUCT APPROVALS WERE SUBMITTED. PROVIDE | | | A PLAN WHICH SHOWS LOCATIONS OF EACH, FBC 107. | | | | | | 5. OK | | | | | | 6. PLAN PROVIDED INDICATES THAT THE STRUCTURE IS MULTI | | | FAMILY. REVISE FLOOR PLAN TO SHOW TENANT SEPARATION, | | | FBC 107. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-12-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-12-29 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-12-29 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2014-12-29 08:42:32 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PROVIDE MULLION AND DOOR PRODUCT APPROVALS, FBC 107, | | | FBC 2010 RESIDENTIAL 301. | | | | | | 2. REVISE FLOOR PLAN TO INCLUDE ROOM DESIGNATIONS. | | | | | | 3. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | | HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND | | | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE | | | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. | | | | | | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION | | | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN | | | HEIGHT: | | | | | | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS | | | - AWNING, CASEMENT, SINGLE HUNG? | | | | | | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. | | | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE | | | WINDOW IS FULLY OPEN. | | | | | | 4. FOR THE IMPACT PROTECTION, COMPLETE THE SAMPLE | | | INSTALLATION SCHEDULE OR PROVIDE ALL INFORMATION TO | | | SHOW CODE COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC | | | R301, FBC1609. TWO SETS REQUIRED. THIS FORM IS | | | AVAILABLE IN THE LOBBY OR ON THE INTERNET AT | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | | | 5. VALUE IS TOO LOW AND HAS BEEN ADJUSTED, FBC 109. IF | | | CONTRACTOR OBJECTS TO NEW VALUATION, PROVIDE EVIDENCE | | | (MATERIAL RECEIPTS, ETC) TO SUPPORT THE VALUE OF $2400 | | | STATED FOR THE 11 WINDOWS, 2 DOORS, AND SHUTTERS. | | | | | | 6. PLAN PROVIDED INDICATES THAT THE STRUCTURE IS MULTI | | | FAMILY. REVISE FLOOR PLAN TO SHOW TENANT SEPARATION, | | | FBC 107. | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-03-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-03-17 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-03-12 |
Time |
08:02 |
Sent To |
B |
|
| Notes |
| 2015-03-16 11:15:18 | 3/16 TO MECHANICAL BOX | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-01-20 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-13 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2015-01-13 18:51:47 | SENT TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-12-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-12-29 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-12-29 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2015-03-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-03-17 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-03-17 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy