| 2014-12-19 07:06:28 | BUILDING PLAN REVIEW |
| | PERMIT: 14120653 |
| | ADD: 4500 S DIXIE |
| | CONT: INNOVATIVE ROOFING |
| | TEL: (954)429-8845 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: FRI. DEC. 19/ 2014 |
| | ACTION: DENIED |
| | |
| | 1) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.41 COMPONENTS & CLADDING |
| | |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES |
| | MISSING ROOFING REPORTS: |
| | ROOF TILE: PROVIDE TYPE OF TILE SIZE OF FOAM PATTY |
| | FOAM HIGHLIGHT (CIRCLE WHICH SIZE FOAM PATTY IS TO BE |
| | INSTALLED WITH MOMENT OF UPLIFT. |
| | |
| | 2) NO INFORMATION HAS BEEN SUBMITTED FOR THE ATTACHMENT |
| | OF THE HIP BOARD AND RIDGE BOARD, NOR THE ATTACHMENT OF |
| | THE TILE TO THE HIP & RIDGE BOARD. |
| | 2010 FBC-B 1507.3.8. |
| | |
| | 3) GAF RUBEROID MODIFIED BITUMEN ROOF SYSTEM OVER WOOD |
| | DECKS NOA 14-0611.01 PAGE 25 SUB-SYSTEM IDENTIFIED WITH |
| | A MAXIMUM DESIGN PRESSURE OF -52.5 SEE LIMITATION # 7. |
| | PLEASE PROVIDE ENHANCED FASTENING FOR ROOF ZONES 2 & 3 |
| | PER RAS 117 CALCULATIONS BY A FL ARCHITECT OR ENGINEER. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |