| 2015-01-05 14:19:03 | BUILDING PLAN REVIEW |
| | REVISION: 14120445 |
| | PERMIT: 12080894 |
| | ADD: 6751 N. JOG RD. |
| | CONT: CDM CONSTRUCTORS |
| | TEL: (561 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 1ST REVIEW |
| | DATE: MON. 01/05/2015 |
| | ACTION: DENIED |
| | |
| | 1) THE SUBMITTED ROOFING PRODUCT APPROVAL NOA |
| | 12-0625.02 FIRESTONE ULTRAPLY TPO & TPO SINGLE PLY ROOF |
| | SYSTEMS OVER STEEL DECKS WAS SUBMITTED FOR REVIEW TO |
| | THE BUILDING DEPARTMENT. PLEASE REVIEW PLANS |
| | 710-S3-300. THE ROOFING DECK IS INDICATED AS A DOUBLE T |
| | CONCRETE DECK SYSTEM AND NOT A STEEL DECK AS PROPOSED |
| | WITH TTHE SUBMITTED PRODUCT APPROVAL. 107.2.1.3 |
| | DISCREPANCY IN EITHER THE PLANS OR SUBMITTED ROOFING |
| | PRODUCT APPROVAL. |
| | |
| | 2) THE SUBMITTED ROOFING PRODUCT APPROVAL NOA |
| | 12-0625.02 FIRESTONE ULTRAPLY TPO & TPO SINGLE PLY ROOF |
| | SYSTEMS OVER STEEL DECKS HAS NOT BEEN REVIEWED BY THE |
| | DESIGNER OF RECORD AND THEIR SHOP DRAWING STAMP OF |
| | APPROVAL AFFIXED. |
| | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 3) PLEASE PROVIDE THE ASSOCIATED WIND DESIGN CRITERIA |
| | AND PRESSURES THAT WILL BE ASSOCIATED WITH THIS ROOFING |
| | SYSTEM. 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE |
| | CODE, THE CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, |
| | DESCRIBE AND DELINEATE THE TYPE OF ROOFING SYSTEM, |
| | MATERIALS, FASTENING REQUIREMENTS, FLASHING |
| | REQUIREMENTS AND WIND RESISTANCE RATING THAT ARE |
| | REQUIRED TO BE INSTALLED. PRODUCT EVALUATION AND |
| | INSTALLATION SHALL INDICATE COMPLIANCE WITH THE WIND |
| | CRITERIA REQUIRED FOR THE SPECIFIC SITE OR A STATEMENT |
| | BY AN ARCHITECT OR ENGINEER FOR THE SPECIFIC SITE MUST |
| | BE SUBMITTED WITH THE CONSTRUCTION DOCUMENTS. |
| | |
| | 4) THE CGC MAY SUBMIT THE ROOFING PRODUCT APPROVALS BUT |
| | A ROOFING CONTRACTOR WILL NEED TO APPLY FOR THE ROOFING |
| | SUB-PERMIT. PLEASE REVIEW : |
| | FL S 489.113 (3) |
| | (B)?A GENERAL, BUILDING, OR RESIDENTIAL CONTRACTOR |
| | SHALL NOT BE REQUIRED TO SUBCONTRACT THE INSTALLATION, |
| | OR REPAIR MADE UNDER WARRANTY, OF WOOD SHINGLES, WOOD |
| | SHAKES, OR ASPHALT OR FIBERGLASS SHINGLE ROOFING |
| | MATERIALS ON A NEW BUILDING OF HIS OR HER OWN |
| | CONSTRUCTION. |
| | (G)?NO GENERAL, BUILDING, OR RESIDENTIAL CONTRACTOR |
| | CERTIFIED AFTER 1973 SHALL ACT AS, HOLD HIMSELF OR |
| | HERSELF OUT TO BE, OR ADVERTISE HIMSELF OR HERSELF TO |
| | BE A ROOFING CONTRACTOR UNLESS HE OR SHE IS CERTIFIED |
| | OR REGISTERED AS A ROOFING CONTRACTOR. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |