Plan Review Details - Permit 14120414
Plan Review Stops For Permit 14120414
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-03-30 Cont ID  
Sent By skennedy Date 2015-03-30 Time 08:25 Rev Time 0.00
Received By skennedy Date 2015-03-30 Time 08:24 Sent To  
Notes
2015-03-30 08:28:174TH REVIEW: FBC 2010
  
 A GENERAL PLAN DEMONSTRATING A 3 DWELLING BUILDING HAS
 BEEN SUBMITTED WITH LITTLE DETAIL. THERE IS A STATEMENT
 THAT THIS IS DIAGNOSTIC AS TO ELECTRICAL AND FOR
 STRUCTURAL FRAMING ENHANCEMENT AT WINDOWS REPLACED
 UNDER A SEOARATE PERMIT. THE IS ISSUES PROVISIONALLY
 SUBJECT TO FIELD INSPECTOR'S DIERCTION.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2015-03-09 Cont ID  
Sent By skennedy Date 2015-03-09 Time 08:27 Rev Time 0.00
Received By skennedy Date 2015-03-09 Time 08:27 Sent To  
Notes
2015-03-09 08:31:061ST REVIEW: FBC 2010
  
 SPOKE TO ROCKY, HE INDICATED THE SCOPE OF WORK IS TO BE
 REVISED TO INCLUDE ALTERATIONS LEVEL I & PERHAPS LEVEL
 II AND VALUATIONTION WILL CHANGE. ACCORDINGLY, THIS
 PLAN REVIEW CYCLE IS ENDED PENDING RESUBMITTAL.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2015-02-15 Cont ID  
Sent By skennedy Date 2015-02-15 Time 10:01 Rev Time 0.00
Received By skennedy Date 2015-02-15 Time 10:01 Sent To  
Notes
2015-02-15 10:02:342ND REVIEW: FBC 2010
  
 PLEASE SEE THE FIRST REVIEW COMMENTS BELOW:
  
 1ST REVIEW: FBC 2010
  
 12/11/14
 SPOKE TO INSPECTOR, HE INDICATED THE VALUE OF THE WORK
 IN QUESTION IS ESTIMATED AT $5,000.00. HE FURTHER
 INDICATED THAT MINIMUM PLAN REVIEW CRITERIA PER FBC 107
 INCLUDING FRAMING DETAILS AND AND EXTERIOR WALL SECTION
 ARE REQUIRED. NO PLANS WERE SUBMITTED AND THE
 APPLICATION VALUE IS STATED AS $500.00. SUBMIT PLANS
 AND REVISE VALUE.
  
 12/10/14 OWNER INDICATED THIS APPLICATION IS REQUIRED
 BY THE INSPECTOR IN ASSOCIATION WITH WORK DONE FOR
 WINDOWS UNDER SEPARATE PERMIT. NEED TO CHECK WITH
 INSPECTOR.
  
 2ND REVIEW: FBC 2010
  
 2/15/15
  
 OWNER MARTIN PIZEL INDICATES THE VALUS OF WORK IS NOW
 $1500.00. THE INSPECTOR STEVE PENTEK CONFIRMS THE VALUE
 IS AT A MINIMUM $5000.00. MR PIZEL INDICATES "HIS GUYS"
 ARE DOING THE WORK. I INFORMED MR. PIZEL THAT THE WORK
 IS REQUIRED TO BE PERFORMED UNDER THE DIRECTION AND
 AUTHORIZATION OF DURANKO JOHN ANDREW, CGC1521555,
  
 PLEASE SUBMIT THE CONTRACT FOR THIS WORK WITH DETAILED
 ESTIMATES OF THE VALUE OF THE WORK. AN APPLICATION HAS
 BEEN SUBMITTED WITH THE ABOVE PARTIES NAMED AS OWNER
 AND CONTRACTOR. PROVIDE CONTRACT CONSISTANT WITH THE
 REQUIREMENTS OF FS 713 AND 489.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-12-11 Cont ID  
Sent By skennedy Date 2014-12-11 Time 12:40 Rev Time 0.00
Received By skennedy Date 2014-12-10 Time 13:06 Sent To  
Notes
2014-12-10 13:08:451ST REVIEW: FBC 2010
  
 12/11/14
 SPOKE TO INSPECTOR, HE INDICATED THE VALUE OF THE WORK
 IN QUESTION IS ESTIMATED AT $5,000.00. HE FURTHER
 INDICATED THAT MINIMUM PLAN REVIEW CRITERIA PER FBC 107
 INCLUDING FRAMING DETAILS AND AND EXTERIOR WALL SECTION
 ARE REQUIRED. NO PLANS WERE SUBMITTED AND THE
 APPLICATION VALUE IS STATED AS $500.00. SUBMIT PLANS
 AND REVISE VALUE.
  
 12/10/14 OWNER INDICATED THIS APPLICATION IS REQUIRED
 BY THE INSPECTOR IN ASSOCIATION WITH WORK DONE FOR
 WINDOWS UNDER SEPARATE PERMIT. NEED TO CHECK WITH
 INSPECTOR.
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2015-03-30 Cont ID  
Sent By skennedy Date 2015-03-30 Time 08:28 Rev Time 0.00
Received By skennedy Date 2015-03-30 Time 08:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-03-30 Cont ID  
Sent By skennedy Date 2015-03-30 Time 08:28 Rev Time 0.00
Received By skennedy Date 2015-03-17 Time 08:50 Sent To  
Notes
2015-03-18 08:51:28SENT TO S KENNEDY

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-03-09 Cont ID  
Sent By skennedy Date 2015-03-09 Time 08:31 Rev Time 0.00
Received By skennedy Date 2015-02-18 Time 08:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-02-15 Cont ID  
Sent By skennedy Date 2015-02-15 Time 10:01 Rev Time 0.00
Received By skennedy Date 2015-02-02 Time 12:56 Sent To  
Notes
2015-02-03 12:57:33RE-SUBMITTAL SENT TO STEVE KENNEDY FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-12-11 Cont ID  
Sent By skennedy Date 2014-12-11 Time 12:40 Rev Time 0.00
Received By skennedy Date 2014-12-10 Time 13:06 Sent To  
Notes
***NONE***