| Plan Review Stops For Permit 14120085 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-01-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-01-27 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-01-27 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2015-01-27 16:23:08 | PROVISO: | | | | | | EVIDENCE OF EXISTING OPENING PROTECTION OR A REVISION | | | OR SEPARATE PERMIT IS REQUIRED PER THE FOLLOWING | | | SECTION TO PROVIDE: | | | FBC - R301.2.1.2 PROTECTION OF OPENINGS. | | | WINDOWS IN BUILDINGS LOCATED IN WINDBORNE DEBRIS | | | REGIONS SHALL HAVE GLAZED OPENINGS PROTECTED FROM | | | WINDBORNE DEBRIS. GLAZED OPENING PROTECTION FOR | | | WINDBORNE DEBRIS SHALL MEET THE REQUIREMENTS OF THE | | | LARGE MISSILE TEST OF ASTM E 1996, ASTM E 1886, SSTD 12 | | | OR TAS 201, 202 AND 203 OR AAMA 506 REFERENCED THEREIN. | | | GARAGE DOOR GLAZED OPENING PROTECTION FOR WINDBORNE | | | DEBRIS SHALL MEET THE REQUIREMENTS OF AN APPROVED | | | IMPACT RESISTING STANDARD OR ANSI/DASMA 115. | | | | | | ADDITIONALLY, THE APPLICANT WAS UNABLE TO PROVIDE A | | | PLAN OF BETTER QUALITY AND CLARITY. IN THE EVENT THE | | | PLANS ARE INSUFFICIENT FOR THE USE OF THE INSPECTOR, | | | THE INSPACTOR MAY REQUIRE ADDITIONAL REVISIONS. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-12-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-19 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-12-19 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2014-12-19 15:54:54 | 1ST REVIEW: FBC 2010 | | | | | | THE SUBMITTED PLANS LACK CLARITY AND REQUIRED DETAIL. | | | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | | SHALL BE | | | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. | | | | | | FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. | | | | | | FBC 107- PROVIDE WALL SECTIONS DEMONSTRATING PROPOSED | | | MATERIALS AND DIMENSIONS OF THE PROPOSED NEW WALL | | | CONFIGURATION. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE A WINDOW SUBMITTAL FOR THE NEW | | | WINDOWS. | | | | | | FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO | | | FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS. | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-01-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-01-27 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-01-27 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-01-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-01-16 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-01-16 |
Time |
14:36 |
Sent To |
HIST |
|
| Notes |
| 2015-01-16 14:45:15 | 2ND REVIEW | | | FBC 2010 | | | | | | SEE FIRST REVIEW COMMENTS. THE NEWLY SUBMITTED 24 X 36 | | | PLAN LACKS IN CLARITY AND DETAIL. APPLICANT STATES ONLY | | | A BATHROOM IAND BEDROOM S BEING ADDED. ELECTRICIAN DID | | | NOT SIGN HIS DESIGN AND INDICATES THE BATH CIRCUITS IN | | | THE PERMIT DESCRIPTION BUT ALSO A NEW FEED FOR A/C | | | UNIT. THE ELECTRICAL DESIGN SHOULD SHOW PER FBC- | | | 107.3.5.3 ? SMOKE DETECTORS PURSUANT TO FBC-R 314.3.1 | | | AS REQUIRED FOR NEW DWELLINGS. IF A ROOM IS BEING | | | CONVERTED TO A BEDROOM THEN: PER NEC 406.11- PROVIDE | | | TAMPER RESISTANT RECEPTACLES & PER NEC 210.12B - | | | OUTLETS TO BE AFCI PROTECTED IN CONVERTED AREA . | | | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-12-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-19 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-12-19 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2014-12-19 16:03:41 | 1ST REVIEW: FBC 2010 | | | | | | THE PLANS ARE NOT SUFFICIENT. | | | | | | SEE BUILDING PLAN REVIEW FOR PLAN QUALITY COMMENTS. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-01-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-01-22 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-01-22 |
Time |
16:39 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-12-11 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-12-11 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-12-11 |
Time |
16:40 |
Sent To |
B |
|
| Notes |
| 2014-12-11 16:40:49 | REQUIRES WINDOW PRODUCT APPROVALS AND ELEVATIONS/PHOTOS | | | TO SEE EXISTING VS PROPOSED. QUESTIONS CONTACT | | | FRIEDERIKE MITTNER AT 822-1457. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-01-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-01-27 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-12-30 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-12-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-19 |
Time |
16:06 |
Rev Time |
|
| Received By |
skennedy |
Date |
2014-12-02 |
Time |
|
Sent To |
|
|
| Notes |
| 2014-12-03 06:03:32 | INCOMING SENT TO R20 . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-01-27 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-01-27 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-01-27 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-01-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-01-16 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-01-16 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2015-01-16 15:35:33 | 2ND REVIEW FBC 2100 | | | | | | SEE THE FIRST REVIEW COMMENTS; APPLICANT STATES THERE | | | ARE NO MECHANICAL IMPROVEMENTS, HOWEVER, THE | | | RECONFIGURATION OF SPACE TO PROVIDE A NEW BATHROOM & | | | BEDROOM. CALLS FOR AN ADDED DUCT AND MEHANICAL | | | VENTILATION. PROVIDE A MECHANICAL PLAN TO DEMONSTRATE | | | COMPLIANCE WITH: | | | FBC 107 - MINIMUM PLAN REVIEW CRITERIA, SHOW DUCT | | | SYSTEM, INCLUDE BALANCED AIR RETURNS. | | | FBCR- M1507.1 GENERAL. | | | WHERE TOILET ROOMS AND BATHROOMS ARE MECHANICALLY | | | VENTILATED, THE VENTILATION EQUIPMENT SHALL BE | | | INSTALLED IN ACCORDANCE WITH THIS SECTION. | | | M1507.2 RECIRCULATION OF AIR. | | | EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS SHALL NOT | | | BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER | | | DWELLING UNIT AND SHALL BE EXHAUSTED DIRECTLY TO THE | | | OUTDOORS. EXHAUST AIR FROM BATHROOMS AND TOILET ROOMS | | | SHALL NOT DISCHARGE INTO AN ATTIC, CRAWL SPACE OR OTHER | | | AREAS INSIDE THE BUILDING. | | | M1507.3 VENTILATION RATE. | | | VENTILATION SYSTEMS SHALL BE DESIGNED TO HAVE THE | | | CAPACITY TO EXHAUST THE MINIMUM AIR FLOW RATE | | | DETERMINED IN ACCORDANCE WITH TABLE M1507.3. | | | TABLE M1507.3 | | | MINIMUM REQUIRED EXHAUST RATES FOR ONE- AND TWO-FAMILY | | | DWELLINGS; BATHROOMS?TOILET ROOMS MECHANICAL EXHAUST | | | CAPACITY OF 50 CFM INTERMITTENT OR 20 CFM | | | CONTINUOUS. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-12-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-19 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-12-19 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2014-12-19 16:06:39 | 1ST REVIEW: FBC 2010 | | | | | | THE PLANS ARE NOT SUFFICIENT. | | | | | | DESCRIBE THE PROPOSED HVAC IMPROVENTS. | | | | | | SEE BUILDING PLAN REVIEW FOR PLAN QUALITY COMMENTS. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-01-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-16 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-16 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-12-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-12-13 |
Time |
05:05 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-12-13 |
Time |
04:51 |
Sent To |
|
|
| Notes |
| 2014-12-13 05:05:05 | 1) SUBMIT TWO COPIES OF A A SANITARY AND WATER RISER | | | FOR REVIEW.WPB AMEND. TO 2010 FBC SEC.107.3.5.3 (11) | | | 2) SHOW THE INTERIOR DIMENSIONS OF THE NEW BATHROOM AND | | | SHOW THE PLUMBING FIXTURE CLEARANCES PER THE 2010 FBC, | | | RESIDENTIAL,SEC.P2705. | | | 3) IS A TUB OR SHOWER BEING INSTALLED IN THE NEW | | | BATH?IF IT IS A SHOWER SHOW THE DIMENSIONS (L X W). | | | COMPLY W/ FBC, RESIDENTIAL, SEC. P2708.1. | | | 4) INDICATE ON THE PLANS THE TYPE OF WALL MATERIAL | | | BEING INSTALLED IN THE TUB/SHOWER WET AREA. THE | | | MATERIAL SHALL COMPLY W/2010 FBCR, SEC.R702.3.8 & | | | R702.3.8.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|