Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-12-11 Cont ID  
Sent By jwitmer Date 2014-12-11 Time 08:13 Rev Time 0.00
Received By jwitmer Date 2014-12-11 Time 07:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-12-09 Cont ID  
Sent By jwitmer Date 2014-12-09 Time 08:46 Rev Time 0.00
Received By jwitmer Date 2014-12-09 Time 08:02 Sent To  
Notes
2014-12-09 08:46:00BUILDING PLAN REVIEW
 PERMIT: 14120080
 ADD: 1551 N FLAGLER # 907
 CONT: INGELD CONTRACTORS LLC
 TEL: (561)215-3819
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. DEC. 09/ 2014
 ACTION: DENIED
  
 1) REPORTS SUBMITTED FOR SAM 90 SOUND CONTROL MEET THE
 SOUND REQUIREMENT FOUND UNDWE SECTION 2010 FBC-B 1207.3
 STRUCTURE-BORNE SOUND BUT NO REPORTS WERE SUBMITTED FOR
 CODE COMPLIANCE FOR FIRE AND ALLOWABLE COMBUSTIBLE
 MATERIALS IN TYPE I,& II CONSTRUCTION FBC-B 603.1.2
 EXC. 2 2. INSULATION INSTALLED BETWEEN A FINISHED FLOOR
 AND SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE
 ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
 200.
  
 THE TEST STANDARD THIS PRODUCT SHOULD BE TESTED TO IS:
  
 703.4.1 ELEMENTARY MATERIALS.
 MATERIALS REQUIRED TO BE NONCOMBUSTIBLE SHALL BE TESTED
 IN ACCORDANCE WITH ASTM E 136.
  
 703.4.2 COMPOSITE MATERIALS.
 MATERIALS HAVING A STRUCTURAL BASE OF NONCOMBUSTIBLE
 MATERIAL AS DETERMINED IN ACCORDANCE WITH SECTION
 703.4.1 WITH A SURFACING NOT MORE THAN 0.125 INCH (3.18
 MM) THICK THAT HAS A FLAME SPREAD INDEX NOT GREATER
 THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL
 723 SHALL BE ACCEPTABLE AS NONCOMBUSTIBLE MATERIALS.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-12-11 Cont ID  
Sent By jwitmer Date 2014-12-11 Time 08:13 Rev Time 0.00
Received By jwitmer Date 2014-12-10 Time 14:23 Sent To  
Notes
2014-12-10 14:23:53RE-SUBMITTAL SENT TO JIM WITMER FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-12-09 Cont ID  
Sent By jwitmer Date 2014-12-09 Time 08:46 Rev Time  
Received By jwitmer Date 2014-12-02 Time   Sent To  
Notes
2014-12-03 05:56:54INCOMING SENT TO BLDG <$5K BOX .


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved