Plan Review Details - Permit 14110888
Plan Review Stops For Permit 14110888
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-12-19 Cont ID  
Sent By shill Date 2014-12-19 Time 09:34 Rev Time 0.00
Received By shill Date 2014-12-19 Time 09:33 Sent To  
Notes
2014-12-19 09:34:29SPOKE WITH APPLICANT - AREA IS NOT A PARKING LOT,
 PAVING ONLY
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-12-19 Cont ID  
Sent By shill Date 2014-12-15 Time 13:37 Rev Time 0.00
Received By shill Date 2014-12-15 Time 13:37 Sent To  
Notes
2014-12-15 13:38:38****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. APPLICATION IS FOR CONCRETE PAVING. PLANS HAVE BEEN
 STAMPED AND A PROVISO ADDED - STRIPING IS NOT A PART OF
 THIS PERMIT.
  
 IF THE INTENTION IS TO BUILD A PARKING LOT, ADDRESS THE
 FOLLOWING:
  
 ****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING
 INFORMATION:
  
 TOTAL NUMBER OF PARKING SPACES
 NUMBER OF ACCESSIBLE SPACES
 LOCATION OF ACCESSIBLE ENTRANCES
 LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES
 SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY
 ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE
 ENTRANCE
  
 SEE FBC 2010 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2
 (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE
 ROUTE).
  
 YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL,
 PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS
 RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE
 PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR
 ACCESSIBLE DESIGN."
  
 HTTP://WWW.ADA.GOV/RESTRIPE.HTM
  
 2. FBC 2010 ACCESSIBILITY ADVISORY 502.3, WHERE THE
 ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES,
 MARKED CROSSINGS ENHANCE PEDESTRIAN SAFETY; PLEASE
 INDICATE LOCATION ON PLAN.
  
 3. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE
 THEIR PRINTED NAME AND SIGNATURE ON THE PLAN, FBC 107.
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2014-12-29 Cont ID  
Sent By cranford Date 2014-12-29 Time 14:01 Rev Time 0.00
Received By cranford Date 2014-12-29 Time 11:19 Sent To I
Notes
2014-12-29 14:00:53AFTER A FIELD INSPECTION, I BELIEVE THE AREA PROPOSED
 TO BE PAVED IS MOSTLY COMPACTED SOIL SINCE THE AREA HAS
 BEEN USED AS VEHICULAR STORAGE FOR THE AUTO REPAIR SHOP
 SINCE THE 1950S. IT IS NOT LIKELY THAT PAVING THE
 COMPACTED AREA WILL RESULT IN A NOTICEABLE INCREASE IN
 OFF-SITE RUNOFF.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2014-12-15 Cont ID  
Sent By cranford Date 2014-12-15 Time 09:47 Rev Time 0.00
Received By cranford Date 2014-12-15 Time 09:34 Sent To B
Notes
2014-12-15 09:47:20THIS APPLICATION IS A REQUEST TO PAVE A CURRENTLY
 UNIMPROVED (DIRT) PARKING AREA, WHICH MAY RESULT IN AN
 INCREASE IN STORMWATER RUNOFF INTO THE CITY'S
 STORMWATER SYSTEM. PLEASE SUBMIT AN APPLICATION FOR
 ENGINEERING DEVELOPMENT PERMIT. APPLICATION FORMS CAN
 BE FOUND AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
 (SECTIONS 2-421 AND 78-432, CODE OF ORDINANCES)
  
 PLEASE SHOW THE DRIVEWAY APRONS MEET THE CITY?S
 ENGINEERING DESIGN STANDARDS WHICH CAN BE DOWNLOADED AT
 HTTP://WPB.ORG/ENGINEERING/ENGINEERING-SERVICES/ENGINE
 ERING-STANDARDS/. PLEASE ALSO INCLUDE THE DETAILS FOR
 THE SIDEWALK RAMPS, THE IMPROVEMENTS ALONG SOUTH DIXIE
 WILL REQUIRE A PERMIT FROM THE FLORIDA DEPARTMENT OF
 TRANSPORTATION. ALSO SEE SECTIONS 94-313 AND 94-485 OF
 THE CITY'S CODE OF ORDINANCES.
  
 SHOW THAT THE PROPOSED PARKING AREA MEETS THE
 REQUIREMENTS OF CODE OF ORDINANCES SECTIONS 94-111,
 94-443(C)(5)(B), FIGURE XIV-2 AND 94-485.
  
 PLEASE DEMONSTRATE THAT THE PROJECT WILL PROVIDE
 ADEQUATE DRAINAGE AND STORMWATER MANAGEMENT. COMPLIANCE
 WITH CHAPTER 40E-4 WILL DEMONSTRATE COMPLIANCE WITH
 THIS PROVISION. [SECTIONS 90-201, 94-35(C )(11), AND
 94-307].
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-12-29 Cont ID  
Sent By cranford Date 2014-12-29 Time 14:01 Rev Time 0.00
Received By cranford Date 2014-12-23 Time 16:43 Sent To  
Notes
2014-12-23 16:44:03INCOMING SENT TO ZONING BOX. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-12-15 Cont ID  
Sent By shill Date 2014-12-15 Time 13:38 Rev Time 0.00
Received By shill Date 2014-11-25 Time 07:22 Sent To  
Notes
2014-11-25 07:23:00SENT TO ZONING BOX. JW

Review Stop Z ZONING
Rev No 2 Status P Date 2014-12-24 Cont ID  
Sent By sgraham Date 2014-12-24 Time 09:04 Rev Time 0.00
Received By sgraham Date 2014-12-24 Time 09:04 Sent To ENG
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2014-11-25 Cont ID  
Sent By sgraham Date 2014-11-25 Time 08:25 Rev Time 0.00
Received By sgraham Date 2014-11-25 Time 08:25 Sent To ENG
Notes
2014-11-25 08:27:3111/30/14 ZONING FAILED
  
 1. THE PLANS MUST SHOW LAYOUT FOR THE PARKING LOT WITH
 THE CAR STOPS AND DOUBLE STRIPPING.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved