| Plan Review Stops For Permit 14110682 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-11-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-30 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-30 |
Time |
17:05 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-11-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-12 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-12 |
Time |
15:31 |
Sent To |
E |
|
| Notes |
| 2015-11-12 15:31:24 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- SIZE OF FOOTING SPECIFIED ON REVISED SHEET A1 | | | DOESN'T MATCH SIZE SHOWN ON FOOTING SCHEDULE ON SHEET | | | A4. REVISE AS REQUIRED. | | | | | | 2- SHUTTERS INSTALLATION SCHEDULE: REVISE THE ANCHOR | | | SPACING FOR THE CALK-IN ANCHOR SPECIFIED. NEED TO USE | | | THE MASONRY COLUMN NOT THE CONCRETE COLUMN. SEE TABLES | | | ON SHEET 5 AND 6 OF 8 OF THE SHUTTERS PRODUCT APPROVAL | | | SUBMITTED AND REVISE AS REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2015-08-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-17 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-17 |
Time |
14:03 |
Sent To |
E |
|
| Notes |
| 2015-08-17 14:04:34 | NOTE: BUILDING REVIEW MAY BE APPROVED WITH PROVISO. | | | COMMENTS BELOW MAY BE ADDRESSED AFTER PERMIT IS ISSUED. | | | FEES MAY APPLY. CONTRACTOR'S RESPONSE IS REQUIRED: | | | REQUESTING PROVISO OR RE-SUBMITTING INFORMATION BELOW. | | | | | | 1- SIZE OF FOOTING SPECIFIED ON PLANS AND SIZE | | | RECOMMENDED ON THE GEOTECHNICAL REPORT DON'T MATCH. | | | REVISE AS REQUIRED TO MATCH OR ARCHITECT TO PROVIDE | | | LETTER ACKNOWLEDGING THAT HE READ THE GEOTHECHNICAL | | | REPORT RECOMMENDATION AND THE FOOTING SIZE HE SPECIFIED | | | IS ADEQUATE. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 2- TYPICAL WALL SECTION ON SHEET A3: COORDINATE SIZE OF | | | FOOTING TO COMPLY WITH THE CLEARANCE FOR TERMITE | | | INSPECTION REQUIRED BY SEC. R704 AND MINIMUM FOOTING | | | DEPTH REQUIRED BY SEC. R403.1.4. A 16" DEEP FOOTING | | | DOESN'T PROVIDE 6" CLEARANCE AND 12" DEPTH BELOW GRADE. | | | REVISE TYPICAL WALL SECTION, FOUNDATION PLAN AND | | | FOOTING SCHEDULE AS REQUIRED AND COORDINATE WITH ITEM | | | #2 ABOVE. | | | | | | 3- SPECIFY THE SIZE OF THE GARAGE DOOR STRUCTURAL BUCK. | | | SEC. R301.1. | | | | | | 4- REVISE THE SHUTTERS INSTALLATION SCHEDULE: SHUTTER | | | MOUNTING CONNECTION TYPE IS INCORRECT. SUBSTRATE IS | | | CONCRETE BLOCK NOT POURED CONCRETE. CLARIFY SHUTTER | | | MOUNTING CONNECTION AND SPECIFIC ANCHOR TYPE. | | | | | | 5- NEW SHEET A4: THE LEFT HAND SIDE OF THE STRUCTURAL | | | NOTES GOT CUT OFF. PROVIDE COMPLETE DRAWING. | | | | | | 6- REVISE THE ENERGY CALCULATIONS: CALCULATIONS NEED TO | | | BE DONE ON THE ACTUAL ORIENTATION OF THE BUILDING. | | | BUILDING IS FACING A TRUE NORTH. THERE ARE NOT NORTH | | | EAST ORIENTATION, ETC. SEC. 103.2.1.1.2 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-12-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-12-12 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-12-12 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2014-12-12 14:54:37 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG. RD.) TO VERIFY IF IMPACT FEES ARE | | | DUE. BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID | | | RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY IMPACT | | | FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE. | | | | | | 2- PROVIDE SOIL TEST REPORT (2 COPIES WITH ENGINEER'S | | | ORIGINAL SEAL AND SIGNATURE). SEC. R401.4 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | 3- SHEET A1: | | | A) PROVIDE INFORMATION FOR THE DROPPED FOOTING SIZE AND | | | REINFORCEMENT BETWEEN GARAGE AND THE REST OF THE HOUSE. | | | SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | B) WINDOW ON BEDROOMS #2 AND #3 DON'T COMPLY WITH | | | EGRESS REQUIREMENTS. SEC. R310.1.2 OF 2010 | | | FBC-RESIDENTIAL. PROVIDE MANUFACTURER'S SPECIFICATIONS | | | SHOWING COMPLIANCE WITH THE REQUIRED CLEAR HEIGHT | | | OPENING OR REVISE SIZE OF WINDOW TO COMPLY. | | | | | | C) CLARIFY THE WIDTH SIZE SPECIFIED ON THE WINDOW | | | SCHEDULE FOR ALL SH 25 WINDOWS. WIDTH DIMENSION OF | | | 2'-2" DOESN'T SEEM TO BE CORRECT. REVISE/CLARIFY AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | D) SPECIFY ATTIC ACCESS. SEC. R807 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | 4- PROVIDE CARBON MONOXIDE ALARMS AS REQUIRED BY SEC. | | | R315 OF 2010 FBC-RESIDENTIAL. | | | | | | 5-TYPICAL WALL SECTION ON SHEET A3: | | | A) SHOW COMPLIANCE WITH THE CLEARANCE REQUIRED FOR | | | TERMITE INSPECTION AS REQUIRED BY SEC. R704 OF 2010 | | | FBC-RESIDENTIAL. | | | | | | B) SPECIFY THE FOOTING MIN. DEPTH AS REQUIRED BY SEC. | | | R403.1.4 OF 2010 FBC-RESIDENTIAL. | | | | | | 6- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION WAS UPGRADED TO $150,000. THE PERMIT FEE | | | BALANCE IS $3142.50. VALUATION TO INCLUDE ALL LABOR, | | | MATERIALS, CONTRACTOR'S OVERHEAD AND PROFIT AND ALL | | | DESIGN PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS TO FBC. | | | | | | 7- PROVIDE GARAGE STRUCTURAL BUCK DETAIL AND | | | SPECIFICATIONS. SEC. R301.1 OF 2010 FBC-RESIDENTIAL. | | | | | | 8- PROVIDE WINDOW AND DOOR MANUFACTURER'S SPECS SHOWING | | | THE U-FACTOR AND SHGC FACTOR SPECIFIED ON THE ENERGY | | | CALCULATIONS ON ITEM #7. SEC. 103.2.2 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | | | | 9- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | DCA RULE 9N-3 FOR: | | | A) PRECAST LINTELS SPECIFIED ON PLANS. | | | | | | B) ENTRY WOOD DOOR AS SPECIFIED ON PLANS AND ENERGY | | | CALCULATIONS (OTHERWISE REVISE PLANS AND ENERGY | | | CALCULATIONS). | | | | | | C) OVERHEAD GARAGE DOOR SIZE AS SPECIFIED ON PLANS. | | | DRAWINGS SUBMITTED ARE FOR 9'-0" MAX. DOOR WIDTH. NEED | | | DRAWINGS FOR 10'-0" WIDE DOORS. | | | | | | D) INSULATED FIBERGLASS DOOR. NEED COMPLETE DRAWINGS. | | | DRAWINGS SUBMITTED ARE CUT IN HALF. PRINT DRAWINGS IN | | | FORMAT THAT WILL PRINT ENTIRE PAGE. | | | | | | 10- DESIGN PROFESSIONAL OF RECORD TO REVIEW AND APPROVE | | | ABOVE PRODUCT APPROVALS. SEC. 107.3.4.1 CITY AMENDMENTS | | | TO FBC. | | | | | | 11- PROVIDE STORM SHUTTERS COMPLETE INSTALLATION | | | SCHEDULE. USE CITY SAMPLE OR PROVIDE COMPLETE REQUIRED | | | INFORMATION UNDER A DIFFERENT FORMAT. SEC. R301.1 OF | | | 2010 FBC-RESIDENTIAL. | | | | | | ****PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ****PLEASE REMOVE AND REPLACE ANY REVISED DRAWING. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-11-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-11-15 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-11-15 |
Time |
11:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-08-18 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-08-18 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-08-18 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-12-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-16 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-12-16 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2014-12-16 10:35:57 | 1ST REVIEW: FBC 2010 | | | | | | FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10 | | | FEET OF EACH SLEEPING ROOM. | | | | | | NEC 210.12B - OUTLETS TO BE AFCI PROTECTED. | | | | | | NEC 210.52(A)(1)&(2) OUTLET SPACING, IT APPEARS SOME | | | POINTS ALONG THE WALL EXCEED 6? FROM AN OUTLET. SEE | | | FRONT DOOR ALONG THE WALL TO THE LEFT IN LIVING ROOM. | | | | | | NEC 210.52(C)(3)-(3) PENINSULAR COUNTERTOP SPACES. AT | | | LEAST ONE RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH | | | PENINSULAR COUNTERTOP SPACE WITH A LONG DIMENSION OF | | | 600 MM (24 IN.) OR GREATER | | | AND A SHORT DIMENSION OF 300 MM (12 IN.) OR GREATER. A | | | PENINSULAR COUNTERTOP IS MEASURED FROM THE CONNECTING | | | EDGE. | | | | | | NEC 210.52(G) BASEMENTS AND GARAGES. FOR A ONE-FAMILY | | | DWELLING THE FOLLOWING PROVISIONS SHALL APPLY: (1) AT | | | LEAST ONE RECEPTACLE OUTLET, IN ADDITION TO THOSE FOR | | | SPECIFIC EQUIPMENT, SHALL BE INSTALLED IN EACH | | | BASEMENT, IN EACH ATTACHED GARAGE, AND IN EACH DETACHED | | | GARAGE WITH ELECTRIC POWER. | | | | | | NEC 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTED | | | REQUIRED FOR GARAGE RECEPTACLE. | | | | | | NEC 406.11- PROVIDE TAMPER RESISTANT RECEPTACLES. | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-11-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-30 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-20 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2015-11-23 11:07:40 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-11-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-11-15 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-11-03 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-08-18 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-08-18 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-07-27 |
Time |
19:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-12-16 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-16 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-11-18 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2014-11-19 07:23:41 | INCOMING SENT TO R-08. JW |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2015-08-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-17 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-17 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2015-08-17 14:33:18 | NO FEES. MU-2015-16564. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-12-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-12-12 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-12-12 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2014-12-12 15:07:20 | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG. RD.) | | | TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK COUNTY | | | STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. | | | REQUIRED BY THE COUNTY IMPACT FEE ORDINANCE OF THE | | | UNIFIED LAND DEVELOPMENT CODE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-11-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-11-12 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-11-12 |
Time |
16:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2015-08-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-17 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-17 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2015-08-17 18:39:23 | NEW SINGLE FAMILY RESIDENCE (R3) SECOND MECHANICAL | | | REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- EQUIPMENT SIZING CALCULATIONS SUBMITTED DON'T | | | IDENTIFY THE PROGRAM THAT WAS ISSUED TO PERFORM THE | | | CALCULATIONS. NEED TO USE APPROVED SOFTWARE. SEE SEC. | | | 403.6 OF 2010 FBC-ENERGY CONSERVATION. | | | | | | 2- EQUIPMENT SIZING CALCULATIONS NEED TO BE DONE BASED | | | ON THE BUILDING LOADS FOR THE ACTUAL DIRECTIONAL | | | ORIENTATION O THE BUILDING. CALCULATIONS SUBMITTED | | | DON'T MATCH ACTUAL BUILDING ORIENTATION. SEE SEC. 403.6 | | | OF 2010 FBC-ENERGY CONSERVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-12-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-12-15 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-12-15 |
Time |
07:20 |
Sent To |
|
|
| Notes |
| 2014-12-15 07:20:34 | NEW SINGLE FAMILY RESIDENCE (R3) MECHANICAL REVIEW | | | COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- A/C PLANS TO HAVE THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. | | | 107.2.1 CITY AMENDMENTS TO FBC. | | | | | | 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS. ONLY | | | THE EQUIPMENT SUMMARY WAS PROVIDED. SEC. 403.6 OF 2010 | | | FBC-ENERGY CONSERVATION. | | | ***NOTE: MAKE SURE CALCUALTIONS ARE DONE BASED ON THE | | | HOUSE ACTUAL BUILDING ORIENTATION AS REQUIRED BY SEC. | | | 406.6. | | | | | | 3- CALCULATIONS TO PROVIDE THE MANUFACTURER AND MODEL | | | NUMBER SHOWING THE SENSIBLE AND TOTAL COOLING CAPACITY | | | AS REQUIRED BY SEC. 403.6 OF 2010 FBC-ENERGY | | | CONSERVATION. | | | | | | 4- HEATING INFORMATION SHOWN ON THE EQUIPMENT SIZING | | | SIZING CALCULATIONS DOESN'T MATCH INFORMATION SHOWN ON | | | THE ENERGY CALCULATIONS. REVISE AS REQUIRED TO MATCH. | | | SEC. 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2015-12-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-12-02 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-12-02 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2015-11-30 17:43:48 | NEW DRAWING SUBMITTED. JG. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-11-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-11-09 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-11-09 |
Time |
17:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-08-03 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-08-03 |
Time |
06:11 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-08-03 |
Time |
05:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-12-04 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-12-04 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-11-26 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2014-12-01 13:56:14 | 12/1/14 | | 2014-11-26 10:50:28 | ***PROVISO*** | | | SUBMIT REVISED SANITARY RISER FOR REVIEW PRIOR TO ROUGH | | | PLUMBING INSPECTION. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2015-08-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-08-17 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-08-17 |
Time |
17:49 |
Sent To |
|
|
| Notes |
| 2015-08-17 17:49:46 | SHINGLES FLORIDA PRODUCT APPROVAL FL1956-R9. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-11-05 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-11-05 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-11-05 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2015-11-05 10:16:36 | 11/5/15 - RESTAMPED REVISED SHEETS. DK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-07-29 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-07-29 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-07-29 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-12-01 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2014-12-01 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-12-01 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2014-12-01 15:07:16 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 12/1/14 | | | | | | ITEMS TO BE ADDRESSED FOR PERMIT: | | | | | | 1. A SEPARATE LANDSCAPE PERMIT IN CONFORMANCE WITH | | | ARTICLE XIV SHALL BE SUBMITTED. (NOTE: ZLDR SEC. | | | 94-442(B)(2)A. - FOR SINGLE-FAMILY DWELLING UNITS, AT | | | LEAST ONE SHADE, FLOWERING, OR FRUIT TREE SHALL BE | | | PLANTED FOR EACH 1,200 SQUARE FEET OF OPEN SPACE OR | | | PORTION THEREOF. FOR SINGLE-FAMILY DWELLING UNITS, AT | | | LEAST ONE SHRUB SHALL BE PLANTED FOR EACH 500 SQUARE | | | FEET OF OPEN SPACE OR PORTION THEREOF.) | | | | | | | | | GENERAL COMMENTS: | | | | | | 1. NOTATION ADDED TO SITE PLAN THAT A/C MUST BE A | | | MINIMUM OF 2.67' FROM THE PROPERTY LINE BASED ON A | | | MAXIMUM 4' ENCROACHMENT OF MECHANICAL INTO A REQUIRED | | | SETBACK. | | | | | | 2. A SEPARATE PERMIT IS REQUIRED FOR THE DRIVEWAY. | | | PLEASE KEEP IN MIND THAT WITHIN THE FRONTYARD SETBACK, | | | A MINIMUM 1,000 SQ. FT. OR 75%, WHICHEVER IS LESS, OF | | | GREEN SPACES [(ZLDR SEC. 94-482(A)] IS REQUIRED. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|