| Plan Review Stops For Permit 14110508 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-11-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-26 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-11-26 |
Time |
16:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-12-19 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-19 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-19 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2014-12-18 13:23:41 | NEW DRAWING SUBMITTED. JG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-11-14 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-14 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-14 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2014-11-14 10:55:46 | 11/14/2014 | | | PROJECT: NAIL SALON | | | PERMIT#: 14110508 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) VERIFY THE INSTALLATION OF NEW OUTLET IN EXISTING | | | FIREWALLS ARE INSTALLED SUCH THAT THE REQUIRED | | | FIRE-RESISTANCE WILL NOT BE REDUCED. FBC 713.3.1 | | | | | | 2) VERIFY BRANCH CIRCUIT FEEDING EMERGENCY AND EXIT | | | LIGHTS SHALL BE THE SAME BRANCH CIRCUIT AS THAT SERVING | | | THE NORMAL LIGHTING IN THE AREA AND CONNECTED AHEAD OF | | | ANY LOCAL SWITCHES. NEC 700.12(F) | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-11-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-11-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-11-17 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2014-11-17 14:00:59 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | ADD 2 ADDITIONAL EMERGENCY LIGHTS, 1 IN THE FRONT AND 1 | | | IN THE BACK, ALONG THE EXIT TRAVEL PATH. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-02-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-02-09 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-01-28 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-12-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-28 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-12-18 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2014-12-18 13:24:14 | RE-SUBMITTAL SENT TO B9 BIN FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-12-02 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-02 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-11-13 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-02-09 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-02-09 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-02-09 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2015-02-09 14:36:02 | PASS PROVISO | | | 1) REFER TO SECTION 501.2.1 LOCATION OF EXHAUST OUTLETS | | | 2010 FBC (M) | | | 2) REFER TO SECTION 503.2.4.40SHUTOFF DAMPER CONTROLS. | | | 2010 FLORIDA ENERGY CODE. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2014-12-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-28 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-12-28 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2014-12-28 11:26:23 | SECOND REVIEW FBC 2010 | | | | | | THE COMMENTS FROM THE FIRST REVIEW WERE APPARENTLY NOT | | | ADDRESSED. SEE BELOW. | | | | | | PLEASE PROVIDE A SYSTEM THAT CAPTURES THE CONTAMINANTS | | | (PRODUCTS) AND ODORS AT THEIR SOURCE, MANICURE TABLES | | | AS PER THE FLORIDA MECHANICAL CODE BELOW | | | | | | 403.3 OUTDOOR AIRFLOW RATE. | | | TABLE 403.3?CONTINUED | | | MINIMUM VENTILATION RATES | | | | | | | | | H. FOR NAIL SALONS, THE REQUIRED EXHAUST SHALL INCLUDE | | | VENTILATION TABLES OR OTHER SYSTEMS THAT CAPTURE THE | | | CONTAMINANTS AND ODORS AT THEIR SOURCE AND ARE CAPABLE | | | OF EXHAUSTING A MINIMUM OF 50 CFM PER STATION. | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-12-02 |
|
|
Cont ID |
|
| Sent By |
rbergsma |
Date |
2014-12-02 |
Time |
|
Rev Time |
1.00 |
| Received By |
rbergsma |
Date |
2014-12-02 |
Time |
|
Sent To |
|
|
| Notes |
| 2014-12-02 10:30:37 | PLEASE PROVIDE A SYSTEM THAT CAPTURES THE CONTAMINANTS | | | (PRODUCTS) AND ODORS AT THEIR SOURCE, MANICURE TABLES | | | AS PER THE FLORIDA MECHANICAL CODE BELOW | | | | | | 403.3 OUTDOOR AIRFLOW RATE. | | | TABLE 403.3?CONTINUED | | | MINIMUM VENTILATION RATES | | | | | | | | | H. FOR NAIL SALONS, THE REQUIRED EXHAUST SHALL INCLUDE | | | VENTILATION TABLES OR OTHER SYSTEMS THAT CAPTURE THE | | | CONTAMINANTS AND ODORS AT THEIR SOURCE AND ARE CAPABLE | | | OF EXHAUSTING A MINIMUM OF 50 CFM PER STATION. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-01-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-30 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-30 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-12-22 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-12-22 |
Time |
06:31 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-12-22 |
Time |
06:06 |
Sent To |
|
|
| Notes |
| 2014-12-22 06:06:18 | 1) THE DRINKING FOUNTAIN SHALL HAVE A 30' WIDE BY 48' | | | CLEAR FLOOR SPACE CENTERED ON THE UNIT TO ALLOW FOR A | | | FORWARD APPROACH PER THE 2010 FL. ACCESS. CODE | | | SEC.602.2. A TURNING DIAMETER DOES NOT COMPLY. | | | 2) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS/ | | | INSTALLATION MANUALS FOR THE PEDICURE CHAIRS. 2ND | | | REQUEST. WPB AMEND. TO 2010 FBC SEC.107.2.1. | | | 3) PROVISIONS FOR THERMAL EXPANSION SHALL BE INSTALLED | | | ON THE HOT WATER SYSTEM PER THE 2010 FL. PLBG. CODE | | | SEC.607.3. | | | 4) WHERE ARE SHEETS A-1 & A-2? SUBMIT 2 COMPLETE SETS | | | OF PLANS WITH ALL THE SHEETS.WPB AMEND. TO 2010 FBC | | | SEC.107.2.1. | | | 5) SHT. P-1 - THE REFERENCE TO SEPARATE FACILITIES NOT | | | BEING REQUIRED FOR ESTABLISHMENTS THAT SEAT 10 PERSONS | | | OR LESS APPLIES TO FOOD SERVICE ESTABLISHMENTS, NOT | | | BUSINESS OCCUPANCIES. THE CORRECT EXCEPTION IS SEC. | | | 403.2 (3) OF THE 2010 FL. PLUMBING CODE. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-11-25 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-11-25 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-11-26 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2014-11-25 09:23:20 | WPB ADMIN. AMEND. TO 201 FBC SEC. 107.2.1. | | | 1) SUBMIT MANUFACTURER'S SPEC SHEETS / INSTALLATION | | | INSTRUCTIONS FOR THE PEDICURE CHAIRS. | | | 2) A NOTE ON THE PLANS STATES THAT THIS IS A CHANGE IN | | | USE. INDICATE THE PREVIOUS USE ON THE PLAN. IF THIS IS | | | A CHANGE IN OCCUPANCY THE WORK SHALL COMPLY WITH | | | CHAPTER 9 OF THE FL. EXISTING BUILDING CODE. | | | 3) A DRINKING FOUNTAIN IS REQUIRED. NO FEWER THAN TWO | | | DRINKING FOUNTAINS SHALL BE PROVIDED PER THE 2010 FAC | | | SEC. 211.2. | | | 4) THE NEW DRINKING FOUNTAINS SHALL BE SHOWN ON THE | | | SANITARY AND WATER RISERS. | | | 5) THE DRINKING FOUNTAINS SHALL BE PROVIDED WITH CLEAR | | | FLOOR SPACE COMPLYING WITH THE 2010 FL. ACCESSIBILITY | | | CODE SECS.306 & 602. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|