| Plan Review Stops For Permit 14110440 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-01-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-16 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-01-15 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2015-01-16 11:27:05 | BUILDING PLAN REVIEW | | | PERMIT: 14110440 | | | ADD: 4115 GEORGIA AVE | | | CONT: T D GONE BUILDING | | | TEL: (561)436-4047 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: FRI. JAN. 16/ 2015 | | | ACTION: BUILDING PROVISO | | | | | | 1) THE DESIGNER OF RECORD PREFERS TO SUBMIT THE PRODUCT | | | APPROVALS FOR WINDOWS AND DOOR AS A DEFERRED SUBMITTAL. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION. | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE | | | BEEN APPROVED BY THE BUILDING OFFICIAL. | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS, SWING DOORS & OVERHEAD DOORS. | | | (B) WINDOWS & MULLIONS | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-12-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-12-02 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-02 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2014-12-02 15:00:06 | BUILDING PLAN REVIEW | | | PERMIT: 14110440 | | | ADD: 4115 GEORGIA AVE | | | CONT: T D GONE BUILDING | | | TEL: (561)436-4047 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. DEC. 02/ 2014 | | | ACTION: DENIED | | | | | | 1) SHEET A1 OF 3 SHOWS DOOR # 5 AS A 1 HOUR FIRE RATED | | | DOOR SEE DOOR SCHEDULE A2. THE WALL SEPARATING THE | | | MERCANTILE FROM THE STORAGE OCCUPANCY DOES NOT INDICATE | | | IF A S1 OR S2, DEPENDING ON THE OCCUPANCY THE WALL | | | BETWEEN THE 2 OCCUPANCIES MAY OR MAY NOT REQUIRE FIRE | | | RATING, SEE FBC-B TABLE 508.4. | | | | | | 2) SHEET A1 OF 3 INDICATES THE INSTALATION OF NEW | | | EXTERIOR WINDOWS AND DOORS, PLEASE SHOW COMPLIANCE WITH | | | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | | CHAPTER 6 OF ASCE 7-10. | | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | | 1609.3 WIND SPEED CONVERSION | | | 2.THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | | | | 2.2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | | | | 2.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.4 & ASCE 7-102010 FBC-B 1609.1.2 | | | PROTECTION OF OPENINGS, 1609.6.4.41 COMPONENTS & | | | CLADDING | | | | | | 2.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | | | 2.5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE | | | TABLE 1609.2(2) . | | | | | | 3) FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 | | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | | | | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA | | | TUS.ASPX FOR PERMIT STATUS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-01-31 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-31 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-31 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-12-31 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-31 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-31 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2014-12-31 11:59:32 | 12/31/2014 | | | PROJECT: GLUE PRODUCTS | | | PERMIT#: 14110440 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE THE CIRCUITRY ON THE FLOOR PLAN TO COINCIDE | | | WITH THE REQUIRED PANEL SCHEDULE AS WELL AS A RISER | | | DIAGRAM AND LOAD CALCULATION. WPB AMENDMENTS ? FBC | | | 107.3.5.1.2 ELECTRICAL | | | | | | 2) PROVIDE COMPLETE CIRCUIT DIRECTORIES FOR ELECTRICAL | | | PANELS. EVERY CIRCUIT SHALL BE LEGIBLY IDENTIFIED AS TO | | | ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. NEC | | | 408.4 | | | | | | 3) DRINKING FOUNTAIN REQUIRES A GFI PROTECTED | | | RECEPTACLE OUTLET. NEC 422.52 | | | | | | 4) INDICATE THE REQUIRED LIGHTING CONTROLS FOR INTERIOR | | | AND EXTERIOR ILLUMINATION. LIGHTING SYSTEMS SHALL BE | | | PROVIDED WITH CONTROLS AS REQUIRED IN SECTIONS 505.2.1, | | | 505.2.2, 505.2.3 AND 505.2.4. FBC 505.2 LIGHTING | | | CONTROLS (MANDATORY). | | | | | | 5) INDICATE THE REQUIRED LIGHTING ABOUT ELECTRICAL | | | EQUIPMENT. ILLUMINATION SHALL BE PROVIDED FOR ALL | | | WORKING SPACES ABOUT ELECTRICAL PANELS AND EQUIPMENT. | | | NEC 110.34 (D) | | | | | | 6) INDICATE THE REQUIRED WORKING CLEARANCE ABOUT | | | ELECTRICAL EQUIPMENT. SUFFICIENT ACCESS AND WORKING | | | SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL | | | ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION | | | AND MAINTENANCE OF SUCH EQUIPMENT. NEC 110.26 | | | | | | 7) VERIFY SAFETY LABELING FOR ARC FLASH PROTECTION FOR | | | THE PANEL BOARDS AND MAIN DISCONNECTING MEANS. NEC | | | 110.16, 110.22 | | | | | | 8) INDICATE ALL REQUIRED EMERGENCY ILLUMINATION. | | | EMERGENCY ILLUMINATION SHALL INCLUDE ALL REQUIRED MEANS | | | OF EGRESS LIGHTING, ILLUMINATED EXIT SIGNS, AND ALL | | | OTHER LIGHTS SPECIFIED AS NECESSARY TO PROVIDE REQUIRED | | | ILLUMINATION. EMERGENCY LIGHTING SYSTEMS SHALL BE | | | DESIGNED AND INSTALLED SO THAT THE FAILURE OF ANY | | | INDIVIDUAL LIGHTING ELEMENT, SUCH AS THE BURNING OUT OF | | | A LAMP, CANNOT LEAVE IN TOTAL DARKNESS ANY SPACE THAT | | | REQUIRES EMERGENCY ILLUMINATION. NEC 700.16 | | | | | | 9) PROVIDE THE LOCATION OF ALL MECHANICAL EQUIPMENT | | | WITH ASSOCIATED REQUIRED DISCONNECTS AND GFI OUTLETS. | | | NEC 210.63, 210.8(A)(3), NEC 440.14 | | | | | | 10) INDICATE PROVISIONS FOR THE REQUIRED SIGN CIRCUIT | | | AND SHOW WINDOW LIGHTING. NEC 210.62, 600.5(A) | | | | | | 11) SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR SITE LIGHTING, GENERATORS. HOOD | | | EXHAUST, FIRE ALARM, ACCESS CONTROL SYSTEM, SECURITY, | | | CCTV, NETWORK, DATA, AND, COMMUNICATION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2015-02-26 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-02-26 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-02-26 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2015-02-26 11:22:54 | ALSO APPROVED UNDER ENGINEERING DEVELOPMENT APPLICATION | | | E14120034 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2015-02-13 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-02-13 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-02-12 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2015-02-13 07:14:35 | ALSO BEING REVIEWED UNDER ENGINEERING APPLICATION | | | E14120034 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2015-01-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-01-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-01-12 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-11-18 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-11-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-11-14 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2014-11-18 09:18:15 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE PLAN SHEETS PACKETS WERE INCONSISTENT. | | | | | | PLEASE PROVIDE THE OCCUPANY CLASSIFICATION. IT APPEARS | | | THAT IT IS OF MISED USE. | | | | | | THE FIRE LINE MAY NEED TO BE APPLIED FOR UNDER A | | | SEPARATE PERMIT, PLEASE CONFIRM WITH CONSTRUCTION | | | SERVICES. | | | | | | A LIFE SAFETY PLAN WAS NOT SUBMITTED THAT INCLUDES ALL | | | OCCUPANCY LOADS, EXIT PATHS, COOMON PATHS OF TRAVEL, | | | EMERGECNY LIGHTS, EXIT SIGNS AND EXITS. ALL EXITS MUST | | | LEAD TO A PUBLIC WAY. EXITING INTO A LOCKED SECURED | | | PARKING LOT IS NOT A PUBLIC WAY. | | | | | | A FIRE SPRINKLER PLAN WAS NOT PROVIDED, AN ENGINEERED | | | CONCEPTUAL PLAN SHALL BE PROVIDED THAT INCLUDES ALL | | | COMMODITIES, STORGAE AND RACK PROTECTION. | | | | | | A FIRE ALARM WAS NOT PROVIDED, AND ENGINEERED | | | CONCEPTUAL PLAN SHALL BE PROVIDED. THE FIRE ALARM | | | SYSTEM SHALL BE MONITORED. | | | | | | A KNOX LOCK KEY SYSTEM, INCLUDING A KNOX BOX AND KNOX | | | GATE ACCESS, SHALL BE PROVIDED FOR 24 HOUR EMERGENCY | | | ACCESS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-02-26 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-02-26 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-02-13 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-02-18 08:36:14 | TO ZONING BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-02-13 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2015-02-13 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2015-01-09 |
Time |
09:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-12-31 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-31 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-12 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2014-11-13 10:52:17 | SENT TO C14 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-12-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-12-02 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-02 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2015-01-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-17 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-17 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-11-24 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-11-24 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-11-24 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2014-11-24 13:22:17 | 1) SHT. A-1 - THE TOILET PAPER DISPENSER SHALL BE | | | LOCATED 7" MIN. AND 9 IN. MAXIMUM IN FRONT OF THE WATER | | | CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. | | | SHOW ON THE PLANS.2010 FL. ACCESS. CODE SEC. 604.7. | | | 2) SHT. A-1 - THE SEAT HEIGHT OF A WATER CLOSET ABOVE | | | THE FINISH FLOOR SHALL BE 17"-19" MAX. SHOW ON THE | | | PLANS.FAC SEC.604.4 | | | 3) GRAB BAR BEHIND WATER CLOSET SHALL BE MOUNTED AT | | | 33"- 36" ABOVE THE FINISH FLOOR PER FAC SEC.609.4. SHOW | | | ON PLANS. | | | 4) SHOW THE CLEAR FLOOR SPACE FOR THE DRINKING | | | FOUNTAINS ON THE PLANS.THE CLEAR FLOOR SPACE SHALL BE | | | CENTERED ON THE INDIVIDUAL FIXTURE AND NOT BOTH | | | FIXTURES. THE CLEAR FLOOR SPACE SHALL BE POSITIONED FOR | | | A FORWARD APPROACH.FAC SEC.602.2. | | | 5) THE DRINKING FOUNTAINS REQUIRE VENTS PER FPC | | | SEC,901.201. | | | 6) FLOOR DRAINS REQUIRE TRAP PRIMERS PER THE 2010 FPC. | | | 1002.4. | | | 7) CLEANOUTS ARE REQUIRED IN THE BASE OF ALL STACKS. | | | PER THE 2010 FPC SEC. 708.3.4. | | | 8)THE WASTE STACKS FOR THE LAVS ARE SHOWN AS 1 1/2 INCH | | | UNDERGROUND AND 2" THROUGH THE ROOF, CLARIFY. | | | 9) A CLEANOUT IS REQUIRED WHERE THE BUILDING DRAIN | | | MEETS THE BUILDING SEWER PER THE 708.3.5. | | | 10) SHT.A-3 - AS DRAWN, THE DRINKING FOUNTAINS ARE | | | DISCHARGING INTO A HORIZONTAL WET VENT WHICH IS NOT | | | PERMITTED PER SEC.909.1 OF THE FPC. | | | 11) SHT. A-3 - A 1 1/2 WET VENT CAN ONLY CARRY ONE | | | DRAINAGE FIXTURE UNIT.AS DRAWN THERE ARE TWO FIXTURE | | | UNITS ON THE 1 1/2" WET VENT AT THE WOMEN'S RESTROOM. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-02-18 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-02-18 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-02-18 |
Time |
10:34 |
Sent To |
ENG |
|
| Notes |
| 2015-02-18 16:25:03 | 2/18/15 - ADDITIONAL NOTATIONS ADDED TO PLAN REGARDING | | | LANDSCAPE PLANTINGS. DK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-01-20 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-01-20 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2015-01-20 10:22:15 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 1/20/15 | | | | | | 1. PLANNING COMMENTS WERE ADDRESSED ON THE COMMENT | | | SHEET PROVIDED WITH RESUBMITAL, HOWEVER, THERE WERE NO | | | REVISIONS TO THE PLANS INCLUDED. (REF. ORIGINAL | | | COMMENTS FROM 11/19/2014). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-11-19 |
|
|
Cont ID |
|
| Sent By |
dkittrid |
Date |
2014-11-19 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2014-11-18 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2014-11-19 09:39:48 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 11/19/14 | | | | | | 1. IT APPEARS THAT ALL VEGETATION IN THE 4 FOOT | | | LANDSCAPE AREA ON THE EAST SIDE OF THE BUILDING IS | | | GOING TO NEED TO BE REMOVED FOR INSTALLATION OF WATER | | | SERVICE CONNECTION AND ASSOCIATED ASSEMBLIES. PLAN WILL | | | NEED TO INDICATE SCREENING THE BACKFLOW PREVENTER AND | | | OTHER VERTICAL COMPONENTS. IT IS RECOMMENDED TO EXPAND | | | THE LANDSCAPE AREA TO THE SOUTH TO BE ABLE TO INSTALL A | | | VEGETATIVE BUFFER FOR SCREENING OF THE EQUIPMENT. | | | PLEASE INDICATE ON THE SITE PLAN IF LANDSCAPING WILL | | | NEED TO BE REMOVED AND HOW THE EQUIPMENT WILL BE | | | SCREENED. | | | | | | 2. A WHEEL STOP WILL NEED TO BE PROVIDED ON THE SECOND | | | TO LAST PARKING SPACE ON THE WEST SIDE OF THE PROPERTY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | 2014-11-14 12:14:38 | 11/14/14 |
|
|