| 2014-12-05 06:08:12 | BUILDING PLAN REVIEW |
| | PERMIT:14110435/ 11090826/ RE-ISSUE |
| | ADD: 14110435 |
| | CONT: EVANS PETRLEUM SERVICES |
| | TEL: (305) 796-9695 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. DEC. 04/ 2014 |
| | ACTION: DENIED |
| | |
| | 1A) THE CANOPY STRUCTURAL CALCULATIONS SUBMITTED BY |
| | UNIVERSAL STRUCTURES JOB NUMBER: 11-4173 DATE SEPT |
| | 19/2011 AND REVISION DATED JAN. 23/2012 |
| | BOTH HAVE THE WRONG ADDRESS ON THEM, THE ADDRESS OF |
| | 1258 PALM BEACH LAKES BLVD. IS A PROPERTY TO THE EAST |
| | WITH ACTIVE PERMITS AND OCCUPANCY. PLEASE CORRECT THE |
| | ADDRESS TO THE CORRECT PROPERTY WHERE THE PERMIT AND |
| | WORK IS OCCURRING. |
| | |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. L. CONSTRUCTION DOCUMENTS SHALL |
| | BE OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, |
| | NATURE AND EXTENT OF THE WORK PROPOSED. |
| | 2010 FBC-B [F] 501.2 ADDRESS IDENTIFICATION. NEW AND |
| | EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED |
| | ADDRESS. |
| | |
| | 1B) THE SUBMITTED PLANS DOES NOT INCLUDE THE CANOPY |
| | FOUNDATION PLANS, CANOPY FRAMING AND ELEVATION PLANS |
| | NOR THE SECTION AND DETAIL PLANS. THIS WAS A REVISION |
| | SUBMITTED LATER ON. PLEASE SUBMIT THE PLANS SUBMITTED |
| | UNDER REVISION NUMBER: 12010568, NOTE THE CANOPY PLANS |
| | ALSO HAVE THE WRONG ADDRESS OF 1258 PALM BEACH LAKES |
| | BLVD. PLEASE SUBMIT THESE PLANS WITH THE CORRECTED |
| | ADDRESS OF 1270 PALM BEACH LAKES BLVD. SO THE PERMIT |
| | PACKAGE WOULD BE COMPLETE. |
| | |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION, 107.2.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. L. CONSTRUCTION DOCUMENTS SHALL |
| | BE OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, |
| | NATURE AND EXTENT OF THE WORK PROPOSED. |
| | 2010 FBC-B [F] 501.2 ADDRESS IDENTIFICATION. NEW AND |
| | EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED |
| | ADDRESS. |
| | |
| | |
| | 12/11/14 UPDATE, IN REVIEWING FILE NET FOR IMPACT FEE |
| | PAYMENT UNDER THE EXPIRED PERMIT11090826 THERE ARE |
| | REVISIONS STATING THE REMOVAL OF THE GAS PUMP CANOPY |
| | FROM THE SCOPE OF WORK UNDER THIS PERMIT. THIS |
| | STATEMENT DOES NOT EXIST UNDER THE NEW RE-ISSUE SET OF |
| | PLANS!!!!!!! |
| | |
| | |
| | 2) THIS PERMIT PACKAGE DOES NOT SHOW ANY UNDERGROUND |
| | INVESTIGATING SOILS REPORTS. UNDER THE ORIGINAL PERMIT |
| | THE REVIEWER ASKED FOR THIS REPORT REPEATEDLY. |
| | CONTRACTOR IS CONTINUING WORK AT THEIR OWN RISK!!!!!!!! |
| | 2010 FBC-B 1803.5.2 QUESTIONABLE SOILS. |
| | |
| | 3) UNDER THE ORIGINAL PERMIT PACKAGE THERE WERE SOIL |
| | DENSITIES TAKEN THAT ARE ALSO MISSING FROM THIS PERMIT |
| | PACKAGE SINCE THERE WAS FILL BROUGHT IN, THEY WERE |
| | NEVER REVIEWED ON THE JOBSITE BY THE INSPECTOR, THEY |
| | PROVISOD AT OWN RISK. PLEASE SUBMIT THESE DOCUMENTS SO |
| | THEY CAN ALSO BE PART OF THIS PERMIT PACKAGE. |
| | 2010 FBC-B 1803.5.8 COMPACTED FILL MATERIAL. WHERE |
| | SHALLOW FOUNDATIONS WILL BEAR ON COMPACTED FILL |
| | MATERIAL MORE THAN 12 INCHES (305 MM) IN DEPTH, A |
| | GEOTECHNICAL INVESTIGATION SHALL BE CONDUCTED AND SHALL |
| | INCLUDE ALL OF THE FOLLOWING: (5.) FIELD TEST METHOD |
| | FOR DETERMINING THE IN-PLACE DRY DENSITY OF THE |
| | COMPACTED FILL. |
| | |
| | 4) THIS PERMIT PACKAGE IS ALSO MISSING THE ROOFING |
| | PRODUCT APPROVALS: |
| | 2010 FBC-B 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.41 COMPONENTS & CLADDING |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES |
| | NOTE: THE ROOFING PRODUCT APPROVALS WERE SUBMITTED |
| | UNDER 12030576 PLEASE SUBMIT ROOFING PRODUCT APPROVALS, |
| | IF ENGINEERED FASTENING IS REQUIRED IN ROOF ZONES 2 & 3 |
| | ALSO SUBMIT ENGINEERED CALCULATIONS TO RAS 117. |
| | |
| | 5) PLEASE PROVIDE DOCUMENTATION THAT UNDER PERMIT # |
| | 11090320 THAT PALM BEACH COUNTY IMPACT FEE OFFICE HAS |
| | REVIEWED AND STAMPED THE PLANS, THERE IS NO SUCH STAMP |
| | ON THESE PLANS. IF A BUILDING WAS DEMOLISHED ON THE |
| | SAME SITE SEE IF THERE IS EXISTING USE CREDITS THAT CAN |
| | BE TAKEN, THE PLANS WILL STILL REQUIRE P B C IMPACT FEE |
| | ASSESSMENT. |
| | |
| | 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |