Plan Review Details - Permit 14110284
Plan Review Stops For Permit 14110284
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-01-26 Cont ID  
Sent By fmittner Date 2015-01-26 Time 13:40 Rev Time 0.00
Received By dhayes Date 2015-01-26 Time 13:01 Sent To Z
Notes
2015-01-26 13:40:5301/07/2015
 PROJECT: PARMALEE RESIDENCE
 PERMIT#: 14110286
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 3RD ELECTRICAL PLAN REVIEW
 ACTION: APPROVED WITH EXCEPTION.
  
 PROVIDE REVISED ELECTRICAL PLANS ADDRESSING THE
 FOLLOWING COMMENTS PRIOR TO INSPECTION.
  
 1) FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN
 FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. FBC WPB AMENDMENTS. SECTION 109.3.
 REVISE THE VALUE ON THE APPLICATION OR PROVIDE
 SUPPORTING DOCUMENTATION OF THE ACTUAL COST OF THE
 ELECTRICAL INSTALLATION INCLUDING ALL OF THE ABOVE
 REFERENCED CRITERIA.
  
 2) PROVIDE A REVISED RISER DIAGRAM INDICATING THE
 CORRECT WIRE SIZE IN ALL CONDUITS. EXISTING SERVICE
 ENTRANCE TO BE ADEQUATE FOR THE 250A MAIN OCPD. FOR THE
 250A. SERVICE ENTRANCE AND FEEDER A MINIMUM 4/0CU IS
 REQUIRED. NEC T-310.15(B)(6).
  
 3) PROVIDE A REVISED PANEL SCHEDULE FOR PANEL "A" AND A
 NEW PANEL SCHEDULE FOR PANEL "B". EVERY CIRCUIT AND
 CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO
 ITS CLEAR, AND SPECIFIC PURPOSE OR USE. NEC 408.4
 INCLUDE ALL NEW CIRCUITS FOR LANDSCAPE LIGHTING,
 FOUNTAIN PUMPS, AND HARDSCAPE FEATURES.
  
 4) REVISE LOAD CALCULATION AS DESCRIBED IN THE NEC
 220.12 , 220.14. LOADS FOR NEW CIRCUITS OR EXTENDED
 CIRCUITS IN PREVIOUSLY WIRED DWELLING UNITS SHALL BE
 CALCULATED IN ACCORDANCE WITH EITHER 220.12 OR 220.14,
 AS APPLICABLE. NEC 220.16(2)
  
 5) PROVIDE LOCATIONS AND ELEVATIONS FOR ALL ELECTRICAL
 EQUIPMENT, TRANSFORMERS AND JUNCTION BOXES IN
 COMPLIANCE WITH NEC 682.
  
 6) ALL PERMANENTLY INSTALLED FOUNTAINS SHALL COMPLY
 WITH NEC 680.50 AS DEFINED IN 680.2.
  
 7) INDICATE THE VOLTAGE ON EACH OF THE FIXTURES.
 INDICATE THE TYPE AND SIZE OF CABLE FOR EACH CIRCUIT.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2015-01-07 Cont ID  
Sent By dhayes Date 2015-01-07 Time 11:00 Rev Time 0.00
Received By dhayes Date 2015-01-07 Time 11:00 Sent To  
Notes
2015-01-07 10:59:5501/07/2015
 PROJECT: PARMALEE RESIDENCE
 PERMIT#: 14110286
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 2ND ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) TWO COPIES OF ALL PLANS AND SPECIFICATIONS ARE
 REQUIRED FOR SUBMITTAL WITH AN APPLICATION FOR PERMIT.
 ONCE REVIEWED AND READY FOR ISSUANCE, ONE SET TO BE
 RETAINED BY THE BUILDING OFFICIAL FOR THE PURPOSE OF
 RECORD KEEPING AND THE OTHER TO BE RETURNED TO THE
 APPLICANT UPON ISSUANCE OF THE PERMIT. WPB AMENDMENTS
 TO THE FBC 107.3.1 SUBMITTAL DOCUMENTS.
 WHILE THERE ARE TWO SETS OF ELECTRICAL PLANS ( E-1 AND
 E-2 SHEETS) THE BALANCE OF THE SUBMITTAL IS A MIX. IN
 ONE SET THERE IS ONE SET OF HARDSCAPE PLANS AND DETAILS
 (H-1 THROUGH H-5) AND FIRST SET OF ELECTRICAL PLANS
 (E-1 AND E-2), HOWEVER THE OTHER SET INCLUDES ONE SET
 OF LANDSCAPE LIGHTING PLANS(LLP-1, LLP-2, AND LLP-3,
 ONE SET OF PLUMBING PLANS (P.1 AND P.2) AND THE SECOND
 SET OF ELECTRICAL (E-1 AND E-2 SHEETS) PROVIDE TWO
 COMPLETE SETS OF CONSTRUCTION DOCUMENTS FOR REVIEW.
  
 2) FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN
 FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. FBC WPB AMENDMENTS. SECTION 109.3.
 REVISE THE VALUE ON THE APPLICATION OR PROVIDE
 SUPPORTING DOCUMENTATION OF THE ACTUAL COST OF THE
 ELECTRICAL INSTALLATION INCLUDING ALL OF THE ABOVE
 REFERENCED CRITERIA.
  
 3) PROVIDE A REVISED PANEL SCHEDULE FOR PANEL "A" AND A
 NEW PANEL SCHEDULE FOR PANEL "B". EVERY CIRCUIT AND
 CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO
 ITS CLEAR, AND SPECIFIC PURPOSE OR USE. NEC 408.4
 INCLUDE ALL NEW CIRCUITS FOR LANDSCAPE LIGHTING,
 FOUNTAIN PUMPS, AND HARDSCAPE FEATUES.
  
 4) PROVIDE THE LOCATIONS FOR THE ELECTRICAL SERVICE,
 ELECTRICAL PANELS "A" AND "B" AND ALL NEW CIRCUITRY ON
 THE SITE (LLP'S) PLANS INCLUDING ALL NEW CIRCUITS FOR
 LANDSCAPE LIGHTING, FOUNTAIN PUMPS, AND HARDSCAPE
 FEATUES. IDENTIFY THE VOLTAGE AND THE CIRCUIT NUMBERS
 CORRESPONDING TO THE PANEL SCHEDULE(S)
  
 5) REVISE LOAD CALCULATION AS DESCRIBED IN THE NEC
 220.12 , 220.14. LOADS FOR NEW CIRCUITS OR EXTENDED
 CIRCUITS IN PREVIOUSLY WIRED DWELLING UNITS SHALL BE
 CALCULATED IN ACCORDANCE WITH EITHER 220.12 OR 220.14,
 AS APPLICABLE. NEC 220.16(2)
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO
 SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED
 SHEETS FOR COMPARATIVE REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-11-25 Cont ID  
Sent By dhayes Date 2014-11-25 Time 08:52 Rev Time 0.00
Received By dhayes Date 2014-11-25 Time 08:52 Sent To  
Notes
2014-11-25 08:59:0911/25/2014
 PROJECT: PARMALEE RESIDENCE
 PERMIT#: 14110286
 CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC
 ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1,
 ADMINISTRATION, 2012 FBC SUPPLEMENTS.
 1ST ELECTRICAL PLAN REVIEW
 ACTION: DENIED
  
 1) TWO COPIES OF ALL PLANS AND SPECIFICATIONS ARE
 REQUIRED FOR SUBMITTAL WITH AN APPLICATION FOR PERMIT.
 ONCE REVIEWED AND READY FOR ISSUANCE, ONE SET TO BE
 RETAINED BY THE BUILDING OFFICIAL FOR THE PURPOSE OF
 RECORD KEEPING AND THE OTHER TO BE RETURNED TO THE
 APPLICANT UPON ISSUANCE OF THE PERMIT. WPB AMENDMENTS
 TO THE FBC 107.3.1 SUBMITTAL DOCUMENTS.
  
 2) FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN
 FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE. FBC WPB AMENDMENTS. SECTION 109.3.
 REVISE THE VALUE ON THE APPLICATION OR PROVIDE
 SUPPORTING DOCUMENTATION OF THE ACTUAL COST OF THE
 ELECTRICAL INSTALLATION INCLUDING ALL OF THE ABOVE
 REFERENCED CRITERIA.
  
 3) REVISE THE RISER DIAGRAM TO INDICATE AN APPROVED
 CONDUCTOR SIZE ADEQUATE TO SUPPORT THE 250AMP MAIN IN
 PANEL A. THE 3/0 CONDUCTORS IN THE RISER ARE
 UNDERSIZED. NEC 310.15(B(6) OR 310.16
  
 4) PROVIDE A REVISED PANEL SCHEDULE FOR PANEL A. EVERY
 CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY
 IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC
 PURPOSE OR USE. NEC 408.4
  
 5) PROVIDE A PANEL SCHEDULE FOR NEW PANEL B. EVERY
 CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY
 IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC
 PURPOSE OR USE. NEC 408.4
  
 6) INDICATE THE LOCATIONS OF THE NEW CIRCUITRY ON THE
 PLANS. IDENTIFY THE VOLTAGE OF EACH CIRCUIT, THE
 CIRCUIT NUMBERS CORRESPONDING TO THE PANEL SCHEDULE AND
 THE LOCATION OF THE REMOTE TRANSFORMERS.
  
 7) REVISE LOAD CALCULATION AS DESCRIBED IN THE NEC
 220.12 , 220.14. LOADS FOR NEW CIRCUITS OR EXTENDED
 CIRCUITS IN PREVIOUSLY WIRED DWELLING UNITS SHALL BE
 CALCULATED IN ACCORDANCE WITH EITHER 220.12 OR 220.14,
 AS APPLICABLE. NEC 220.16(2)
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. SEE LINK:
 HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/
 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF
  
 ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO
 SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED
 SHEETS FOR COMPARATIVE REVIEW.
  
 DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421,
 561-805-6717 OR [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-01-29 Cont ID  
Sent By dhayes Date 2015-01-29 Time 08:56 Rev Time 0.00
Received By shill Date 2015-01-26 Time 13:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2015-01-07 Cont ID  
Sent By dhayes Date 2015-01-07 Time 11:00 Rev Time 0.00
Received By dhayes Date 2015-01-06 Time 09:47 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-11-25 Cont ID  
Sent By dhayes Date 2014-11-25 Time 08:59 Rev Time 0.00
Received By dhayes Date 2014-11-25 Time 08:59 Sent To  
Notes
2014-11-06 14:39:32ROUTED TO ELECTRICAL 5000 AND UNDER

Review Stop Z ZONING
Rev No 2 Status P Date 2015-01-28 Cont ID  
Sent By fmittner Date 2015-01-28 Time 11:01 Rev Time 0.00
Received By fmittner Date 2015-01-28 Time 11:01 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-01-05 Cont ID  
Sent By fmittner Date 2014-12-18 Time 14:31 Rev Time 0.00
Received By fmittner Date 2014-12-18 Time 14:31 Sent To  
Notes
2014-12-18 14:55:00FILED UNDER SMALL PLANS DENIED K
2014-12-18 14:32:16WALL HEIGHTS/SETBACKS NOT DEPICTED ON PLAN.