 |
Plan Review Details - Permit 14110284
| Plan Review Stops For Permit 14110284 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-01-26 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-01-26 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-26 |
Time |
13:01 |
Sent To |
Z |
|
| Notes |
| 2015-01-26 13:40:53 | 01/07/2015 | | | PROJECT: PARMALEE RESIDENCE | | | PERMIT#: 14110286 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 3RD ELECTRICAL PLAN REVIEW | | | ACTION: APPROVED WITH EXCEPTION. | | | | | | PROVIDE REVISED ELECTRICAL PLANS ADDRESSING THE | | | FOLLOWING COMMENTS PRIOR TO INSPECTION. | | | | | | 1) FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR | | | FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN | | | FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | | ONLY LAND VALUE. FBC WPB AMENDMENTS. SECTION 109.3. | | | REVISE THE VALUE ON THE APPLICATION OR PROVIDE | | | SUPPORTING DOCUMENTATION OF THE ACTUAL COST OF THE | | | ELECTRICAL INSTALLATION INCLUDING ALL OF THE ABOVE | | | REFERENCED CRITERIA. | | | | | | 2) PROVIDE A REVISED RISER DIAGRAM INDICATING THE | | | CORRECT WIRE SIZE IN ALL CONDUITS. EXISTING SERVICE | | | ENTRANCE TO BE ADEQUATE FOR THE 250A MAIN OCPD. FOR THE | | | 250A. SERVICE ENTRANCE AND FEEDER A MINIMUM 4/0CU IS | | | REQUIRED. NEC T-310.15(B)(6). | | | | | | 3) PROVIDE A REVISED PANEL SCHEDULE FOR PANEL "A" AND A | | | NEW PANEL SCHEDULE FOR PANEL "B". EVERY CIRCUIT AND | | | CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO | | | ITS CLEAR, AND SPECIFIC PURPOSE OR USE. NEC 408.4 | | | INCLUDE ALL NEW CIRCUITS FOR LANDSCAPE LIGHTING, | | | FOUNTAIN PUMPS, AND HARDSCAPE FEATURES. | | | | | | 4) REVISE LOAD CALCULATION AS DESCRIBED IN THE NEC | | | 220.12 , 220.14. LOADS FOR NEW CIRCUITS OR EXTENDED | | | CIRCUITS IN PREVIOUSLY WIRED DWELLING UNITS SHALL BE | | | CALCULATED IN ACCORDANCE WITH EITHER 220.12 OR 220.14, | | | AS APPLICABLE. NEC 220.16(2) | | | | | | 5) PROVIDE LOCATIONS AND ELEVATIONS FOR ALL ELECTRICAL | | | EQUIPMENT, TRANSFORMERS AND JUNCTION BOXES IN | | | COMPLIANCE WITH NEC 682. | | | | | | 6) ALL PERMANENTLY INSTALLED FOUNTAINS SHALL COMPLY | | | WITH NEC 680.50 AS DEFINED IN 680.2. | | | | | | 7) INDICATE THE VOLTAGE ON EACH OF THE FIXTURES. | | | INDICATE THE TYPE AND SIZE OF CABLE FOR EACH CIRCUIT. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-01-07 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-07 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-07 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2015-01-07 10:59:55 | 01/07/2015 | | | PROJECT: PARMALEE RESIDENCE | | | PERMIT#: 14110286 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) TWO COPIES OF ALL PLANS AND SPECIFICATIONS ARE | | | REQUIRED FOR SUBMITTAL WITH AN APPLICATION FOR PERMIT. | | | ONCE REVIEWED AND READY FOR ISSUANCE, ONE SET TO BE | | | RETAINED BY THE BUILDING OFFICIAL FOR THE PURPOSE OF | | | RECORD KEEPING AND THE OTHER TO BE RETURNED TO THE | | | APPLICANT UPON ISSUANCE OF THE PERMIT. WPB AMENDMENTS | | | TO THE FBC 107.3.1 SUBMITTAL DOCUMENTS. | | | WHILE THERE ARE TWO SETS OF ELECTRICAL PLANS ( E-1 AND | | | E-2 SHEETS) THE BALANCE OF THE SUBMITTAL IS A MIX. IN | | | ONE SET THERE IS ONE SET OF HARDSCAPE PLANS AND DETAILS | | | (H-1 THROUGH H-5) AND FIRST SET OF ELECTRICAL PLANS | | | (E-1 AND E-2), HOWEVER THE OTHER SET INCLUDES ONE SET | | | OF LANDSCAPE LIGHTING PLANS(LLP-1, LLP-2, AND LLP-3, | | | ONE SET OF PLUMBING PLANS (P.1 AND P.2) AND THE SECOND | | | SET OF ELECTRICAL (E-1 AND E-2 SHEETS) PROVIDE TWO | | | COMPLETE SETS OF CONSTRUCTION DOCUMENTS FOR REVIEW. | | | | | | 2) FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR | | | FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN | | | FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | | ONLY LAND VALUE. FBC WPB AMENDMENTS. SECTION 109.3. | | | REVISE THE VALUE ON THE APPLICATION OR PROVIDE | | | SUPPORTING DOCUMENTATION OF THE ACTUAL COST OF THE | | | ELECTRICAL INSTALLATION INCLUDING ALL OF THE ABOVE | | | REFERENCED CRITERIA. | | | | | | 3) PROVIDE A REVISED PANEL SCHEDULE FOR PANEL "A" AND A | | | NEW PANEL SCHEDULE FOR PANEL "B". EVERY CIRCUIT AND | | | CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO | | | ITS CLEAR, AND SPECIFIC PURPOSE OR USE. NEC 408.4 | | | INCLUDE ALL NEW CIRCUITS FOR LANDSCAPE LIGHTING, | | | FOUNTAIN PUMPS, AND HARDSCAPE FEATUES. | | | | | | 4) PROVIDE THE LOCATIONS FOR THE ELECTRICAL SERVICE, | | | ELECTRICAL PANELS "A" AND "B" AND ALL NEW CIRCUITRY ON | | | THE SITE (LLP'S) PLANS INCLUDING ALL NEW CIRCUITS FOR | | | LANDSCAPE LIGHTING, FOUNTAIN PUMPS, AND HARDSCAPE | | | FEATUES. IDENTIFY THE VOLTAGE AND THE CIRCUIT NUMBERS | | | CORRESPONDING TO THE PANEL SCHEDULE(S) | | | | | | 5) REVISE LOAD CALCULATION AS DESCRIBED IN THE NEC | | | 220.12 , 220.14. LOADS FOR NEW CIRCUITS OR EXTENDED | | | CIRCUITS IN PREVIOUSLY WIRED DWELLING UNITS SHALL BE | | | CALCULATED IN ACCORDANCE WITH EITHER 220.12 OR 220.14, | | | AS APPLICABLE. NEC 220.16(2) | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-11-25 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-25 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-25 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2014-11-25 08:59:09 | 11/25/2014 | | | PROJECT: PARMALEE RESIDENCE | | | PERMIT#: 14110286 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) TWO COPIES OF ALL PLANS AND SPECIFICATIONS ARE | | | REQUIRED FOR SUBMITTAL WITH AN APPLICATION FOR PERMIT. | | | ONCE REVIEWED AND READY FOR ISSUANCE, ONE SET TO BE | | | RETAINED BY THE BUILDING OFFICIAL FOR THE PURPOSE OF | | | RECORD KEEPING AND THE OTHER TO BE RETURNED TO THE | | | APPLICANT UPON ISSUANCE OF THE PERMIT. WPB AMENDMENTS | | | TO THE FBC 107.3.1 SUBMITTAL DOCUMENTS. | | | | | | 2) FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE | | | STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR | | | FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN | | | FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | | ONLY LAND VALUE. FBC WPB AMENDMENTS. SECTION 109.3. | | | REVISE THE VALUE ON THE APPLICATION OR PROVIDE | | | SUPPORTING DOCUMENTATION OF THE ACTUAL COST OF THE | | | ELECTRICAL INSTALLATION INCLUDING ALL OF THE ABOVE | | | REFERENCED CRITERIA. | | | | | | 3) REVISE THE RISER DIAGRAM TO INDICATE AN APPROVED | | | CONDUCTOR SIZE ADEQUATE TO SUPPORT THE 250AMP MAIN IN | | | PANEL A. THE 3/0 CONDUCTORS IN THE RISER ARE | | | UNDERSIZED. NEC 310.15(B(6) OR 310.16 | | | | | | 4) PROVIDE A REVISED PANEL SCHEDULE FOR PANEL A. EVERY | | | CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY | | | IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC | | | PURPOSE OR USE. NEC 408.4 | | | | | | 5) PROVIDE A PANEL SCHEDULE FOR NEW PANEL B. EVERY | | | CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY | | | IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC | | | PURPOSE OR USE. NEC 408.4 | | | | | | 6) INDICATE THE LOCATIONS OF THE NEW CIRCUITRY ON THE | | | PLANS. IDENTIFY THE VOLTAGE OF EACH CIRCUIT, THE | | | CIRCUIT NUMBERS CORRESPONDING TO THE PANEL SCHEDULE AND | | | THE LOCATION OF THE REMOTE TRANSFORMERS. | | | | | | 7) REVISE LOAD CALCULATION AS DESCRIBED IN THE NEC | | | 220.12 , 220.14. LOADS FOR NEW CIRCUITS OR EXTENDED | | | CIRCUITS IN PREVIOUSLY WIRED DWELLING UNITS SHALL BE | | | CALCULATED IN ACCORDANCE WITH EITHER 220.12 OR 220.14, | | | AS APPLICABLE. NEC 220.16(2) | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-01-29 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-29 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-26 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-01-07 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-07 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-06 |
Time |
09:47 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-11-25 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-25 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-25 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2014-11-06 14:39:32 | ROUTED TO ELECTRICAL 5000 AND UNDER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2015-01-28 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-01-28 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-01-28 |
Time |
11:01 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-01-05 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-12-18 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-12-18 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2014-12-18 14:55:00 | FILED UNDER SMALL PLANS DENIED K | | 2014-12-18 14:32:16 | WALL HEIGHTS/SETBACKS NOT DEPICTED ON PLAN. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |