Plan Review Details - Permit 14110244
| Plan Review Stops For Permit 14110244 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2014-11-18 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-11-18 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-11-18 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2014-11-18 15:39:18 | 1ST REVIEW: FBC 2010 | | | | | | THE QUALITY OF THE PLAN IS NOT ACCEPTABLE. FBC | | | 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. | | | | | | PROVIDE A SOFFIT DETAIL. FBC 107. - | | | | | | THERE IS ADDED VALUE OF WORK. PROVIDE ESTIMATE OF ADDED | | | VALUE AND AND PAY FEE. FBC 109.3 BUILDING PERMIT | | | VALUATION. FOR PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | | INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND | | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE | | | CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET | | | BY THE BUILDING OFFICIAL. | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-06-16 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-06-16 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-06-16 |
Time |
13:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-11-18 |
|
|
Cont ID |
|
| Sent By |
sciard |
Date |
2014-11-18 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
sciard |
Date |
2014-11-18 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2014-11-18 12:13:24 | 1. FBC 107.2.1.4. CLARITY OF PLANS. | | | 2. N.E.C. 210.12. ARC-FAULT PROTECTION FOR NEW CIRCUITS | | | ADDED. | | | 3. FBC 107.3.5.3. PROVIDE LOAD CALCULATION. | | | 4. FBC SECTION R314 LOCATION OF SMOKE ALARMS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-06-16 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-06-16 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-06-15 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-11-18 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-11-18 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-11-06 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2014-11-06 10:40:26 | TO SAK | | | |
|
|
|