| 2014-11-05 10:22:11 | BUILDING PLAN REVIEW |
| | PERMIT:14101060 |
| | ADD: 800 HANK AARON DRIVE |
| | CONT: KAST |
| | TEL: (561) 346-4994 |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. NOV. 05/2014 |
| | ACTION: DENIED |
| | |
| | 1) THE PERMIT APPLICATION INDICATES WORK UNDER THIS |
| | PERMIT TO BE LOCATED AT 800 HANK AARON DRIVE. KAST |
| | CONSTRUCTION SUBMITTED ADDRESSES TO BE USED BEFORE THE |
| | BUILDING PERMIT WERE ISSUED. THE SITE ADDRESS TO BE |
| | USED IS NOW 1590 CAMERON SAMUEL LN. PLEASE MAKE |
| | CORRECTIONS TO THE PERMIT APPLICATION AND PLANS UNLESS |
| | THE CONTRACTOR IS LOOKING FOR A ADDRESS FOR THIS UNIT |
| | ONLY, THEN A NEW ADDRESS WILL BE REQUIRED. |
| | CONTACT: SCOTT ALEF 494-1094. |
| | |
| | 2) THE STATE APPROVED PLANS HAVE BEEN MINIATURIZED |
| | BEYOND 1/8 INCH EQUALLS 1 FOOT. THE PLANS ARE ELIGIBLE. |
| | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION 107.2.1.4 QUALITY OF |
| | BUILDING PLANS. BUILDING PLANS SHALL BE DRAWN TO A |
| | MINIMUM 1/8 INCH |
| | SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE |
| | MEDIUM. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH |
| | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND |
| | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS |
| | RECORD RETENTION PROGRAM. |
| | |
| | 3) THE ANCHORING PLAN IS A COPY, THE STATE APPROVED |
| | PLANS DO NOT INCLUDE THE FOUNDATION PLAN. |
| | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS |
| | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR |
| | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE |
| | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| | FL ADMIN CODE 61G16.003 ARCHITECTS |
| | FL ADMIN CODE 61G15-23.002 ENGINEERS |
| | |
| | 4) THERE IS NO INDICATION IF THIS IS A TEMPORARY |
| | STRURCTURE, LESS THAN 180 DAYS ON THE PERMIT |
| | APPLICATION. MODULAR BUILDINGS THAT ARE IN PLACE OVER |
| | 180 DAYS ARE NOT TEMPORARY AND WOULD NEED TO MEET THIS |
| | BUILDING REQUIREMENT. 2010 FBC-B 1809.4 DEPTH AND WIDTH |
| | OF FOOTINGS. |
| | THE MINIMUM DEPTH OF FOOTINGS BELOW THE UNDISTURBED |
| | GROUND SURFACE SHALL BE 12 INCHES (305 MM). WHERE |
| | APPLICABLE, THE REQUIREMENTS OF SECTION 1809.5 SHALL |
| | ALSO BE SATISFIED. THE MINIMUM WIDTH OF FOOTINGS SHALL |
| | BE 12 INCHES (305 MM). |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |