Plan Review Details - Permit 14101036
| Plan Review Stops For Permit 14101036 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-11-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-19 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-19 |
Time |
17:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2014-10-31 11:14:10 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC 2010 | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | BUILDING | | | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 2) THE SIGNED CONTRACT THAT WAS SUBMITTED IS FOR | | | $17,091.94 AND THE VALUE ON THE PERMIT APPLICATION IS | | | $8,971.00. FBC 109.3 BUILDING PERMIT VALUATION. FOR | | | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS | | | SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-11-14 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-14 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-14 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2014-11-14 11:40:50 | 11/14/2014 | | | PROJECT: MASTER BATH RENNOVATIUON | | | PERMIT#: 14101036 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) IN ADDITION TO THE NUMBER OF BRANCH CIRCUITS | | | REQUIRED BY OTHER PARTS OF THIS SECTION, AT LEAST ONE | | | 20-AMPERE BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY | | | BATHROOM RECEPTACLE OUTLET(S). SUCH CIRCUITS SHALL HAVE | | | NO OTHER OUTLETS. NEC 210.11(C)(3) | | | | | | 2) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A | | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL | | | 314 AND 315 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-11-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-19 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-13 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2014-11-14 17:50:57 | 11/14 TO RM DESK | | | | | 2014-11-14 11:54:53 | MISC. 2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-11-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-11-19 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-11-19 |
Time |
17:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-10-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2014-10-31 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
|