Plan Review Details - Permit 14101000
| Plan Review Stops For Permit 14101000 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-11-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-06 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-11-06 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-11-20 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-20 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-20 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2014-11-20 13:53:34 | 11/20/2014 | | | PROJECT: LOFT APTS | | | PERMIT#: 14101000 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) GFP OF EQUIPMENT REQUIRED ON WYE ELECTRICAL SYSTEMS | | | OF MORE THAN 150V TO GROUND AND NOT EXCEEDING 600VOLTS | | | PHASE TO PHASE FOR EACH SERVICE DISCONNECT OVER | | | 1000AMPS. NEC230.95 | | | | | | 2) THE GROUND-FAULT PROTECTION SYSTEM SHALL BE | | | PERFORMANCE TESTED WHEN FIRST INSTALLED ON SITE AND A | | | RECORD OF THE TEST SHALL BE AVAILABLE FOR THE INSPECTOR | | | ON SITE. NEC 230.95(C) | | | | | | 3) THE LINE DIAGRAM INDICATE A 600AMP METER CAN AHEAD | | | OF PANEL HDP. THERE ARE NO METER CAN APPROVED FOR | | | 600AMPS. REVISE PLANS ACCORDINGLY. | | | | | | 4) VERIFY THE FIRE PUMP FEEDERS, CIRCUIT CONDUCTORS, | | | AND PUMP WIRING ARE APPROPRIATELY FIRE PROTECTED. | | | INDICATE THE FIRE RATING AND MATERIAL PROPSED. NEC | | | 695.6, 695.14 | | | | | | 5) VERIFY THE FIRE PUMP FEEDERS ARE SIZED WITH A RATING | | | NOT LESS THAN 125% OF THE SUM OF THE FIRE PUMP MOTOR, | | | PRESSURE MAINTENANCE MOTORS AND 100 PERCENT OF THE | | | ACCESSORIES. VERIFY THE MAXIMUM VOLTAGE DROP IS NOT | | | MORE THAN 15 % BELOW NORMAL STARTING AND 5% BELOW WHEN | | | THE MOTOR IS OPERATING AT 115% OF THE FULL LOAD CURRENT | | | RATING. NEC 695.6, 695.7 | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-11-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-11-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-11-05 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-11-20 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-20 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-30 |
Time |
17:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-11-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-11-18 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-11-18 |
Time |
13:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-11-19 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2014-11-19 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2014-11-19 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2014-11-14 12:08:01 | 11/14/14 |
|
|
|