Plan Review Details - Permit 14100982
| Plan Review Stops For Permit 14100982 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-11-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-11-06 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-11-06 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-10-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-10-30 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-10-30 |
Time |
13:33 |
Sent To |
|
|
| Notes |
| 2014-10-30 16:36:36 | ROOF RECOVER BUILDING REVIEW COMMENTS. | | | CODE: 2010 FBC. | | | | | | 1- REVISE THE RAS 117 CALCULATIONS SUBMITTED. THE | | | ENGINEER NEEDS TO UTILIZE THE WITHDRAWAL RESISTANCE | | | VALUE TAKEN FROM THE TESTING APPLICATION STANDARD (TAS | | | 105) AS REQUIRED BY LIMITATION #5.4 FROM FLORIDA | | | PRODUCT APPROVAL FL16440-R2 SUBMITTED. SEC. 1609 OF | | | 2010 FBC. | | | | | | 2- RECOVER INSTALLATIONS REQUIRES AN INSPECTION OF THE | | | EXISTING ROOF AS REQUIRED BY LIMITATION #5.6 OF FLORIDA | | | PRODUCT APPROVAL FL16440-R2. ALSO, CITY OF WEST PALM | | | BEACH REQUIRES A BUILDING PRE-INSPECTION (INSPECTION | | | CODE 101) ONCE THE PERMIT IS ISSUED AND BEFORE ANY WORK | | | IS DONE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-11-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2014-11-06 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2014-11-06 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2014-11-06 13:19:52 | FIRST RE-SUBMITTAL. JG. |
|
|
|
Account Summary | Usage Policy | Privacy Policy