Plan Review Details - Permit 14100826
| Plan Review Stops For Permit 14100826 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
N |
Date |
2015-01-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-01-21 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-21 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2015-01-21 13:11:47 | SEE MASTER FOR REVIEWS | | | 14120915 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2014-11-25 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-25 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-25 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2014-11-25 07:54:32 | 11/25/2014 | | | PROJECT: LJUBO | | | PERMIT#: 14100826 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 3RD ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) ACCORDING TO CODE ENFORCEMENT REPORT CASE # CE | | | 14070585, THE VIOLATION INCLUDES INTERIOR ALTERATIONS | | | /EXTERIOR WORK THAT WAS DONE WITHOUT THE BENEFIT OF | | | PERMITS AND INSPECTIONS. THE ELECTRICAL PERMIT CANNOT | | | BE ISSUED UNTIL A FULL SET OF PROFESSIONALLY DRAWN | | | PLANS DONE BY A DESIGN PROFESSIONAL LICENSED IN THE | | | STATE OF FLORIDA IN ACCORDANCE WITH FL. STATUTES 471 & | | | 481 ARE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW | | | AND APPROVAL. THE PLANS SHALL INCLUDE ALL THE | | | INFORMATION, DETAILS AND APPROVALS REQUIRED BY SEC. | | | 107.3.5.3 OF THE WPB AMEND. TO 2010 FL. BLDG. CODE FOR | | | PLAN REVIEW FOR THIS STRUCTURE. ELECTRICAL PLAN REVIEW. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-11-03 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-03 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-03 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2014-11-03 12:07:58 | 11/3/2014 | | | PROJECT: LJUBO | | | PERMIT#: 14100826 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | DUPLICATE COMMENTS: | | | 1) PROVIDE A MORE DETAILED PLAN. PROVIDE AT LEAST THE | | | MINIMUM PLAN REVIEW CRITERIA. PLEASE INCLUDE THE | | | FOLLOWING IN YOUR SUBMITTAL: WPB AMENDMENTS TO THE FBC | | | 107.3.2 | | | A) A PANEL SCHEDULE THAT INCLUDES THE CIRCUIT AND OCPD | | | FOR THE WATER HEATER. | | | B) A RISER DIAGRAM INDICATING THE SIZE OF THE | | | ELECTRICAL SERVICE. | | | C) THE OCPD FEEDING THE PANEL. | | | D) THE LOCATION, SIZE, WIRING MEATHOD AND MEANS OF | | | DISCONNECT FOR THE WATER HEATER. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-10-29 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-10-29 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-29 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2014-10-29 08:25:55 | 10/29/2014 | | | PROJECT: LJUBO | | | PERMIT#: 14100826 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE A MORE DETAILED PLAN. PROVIDE AT LEAST THE | | | MINIMUMPLAN REVIEW CRITERIA. PLEASE INCLUDE THE | | | FOLLOWING IN YOUR SUBMITTAL: WPB AMENDMENTS TO THE FBC | | | 107.3.2 | | | A) A PANEL SCHEDULE THAT INCLUDES THE CIRCUIT AND OCPD | | | FOR THE WATER HEATER. | | | B) A RISER DIAGRAM INDICATING THE SIZE OF THE | | | ELECTRICAL SERVICE. | | | C) THE OCPD FEEDING THE PANEL. | | | D) THE LOCATION, SIZE, WIRING MEATHOD AND MEANS OF | | | DISCONNECT FOR THE WATER HEATER. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-11-25 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-25 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-17 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2014-11-18 08:46:09 | SENT TO D HAYES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-11-03 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-03 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-03 |
Time |
12:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-10-29 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-10-29 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-27 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2014-10-27 12:59:23 | ROUTED TO ELECTRICAL $5000 & UNDER |
|
|
|