Plan Review Details - Permit 14100819
| Plan Review Stops For Permit 14100819 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-12-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-12-19 |
Time |
07:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-19 |
Time |
07:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-11-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-05 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-11-05 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2014-11-05 09:49:59 | BUILDING PLAN REVIEW | | | PERMIT: 14100819 | | | ADD: 533 CLEMATIS ST. | | | CONT: SULLIVAN | | | TEL: (561)305-1465 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. NOV. 05/ 2014 | | | ACTION: DENIED | | | | | | 1) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, | | | 107.2.1.ADDITIONAL INFORMATION IS REQUIRED. | | | THE PERMIT APPLICATION INDICATES THIS TO BE INTERIOR | | | DEMO ONLY OF A BAR, FOR A VALUE OF $15,000.00. NO | | | DEMOLITON PLANS WERE SUBMITTED. | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | 2) COVERSHEET CODE ANALYSIS: | | | 2A) TYPE V, SPRINKLERED, PLEASE IDENTIFY IF THIS IS A | | | VA OR VB BUILDING TYPE. 2010 FBC-B TABLE 503. | | | 2B) OCCUPANCY CLASSIFICATION A2 SMALL ASSEMBLY, THIS IS | | | OLD CODE LANGUAGE, A A2 OCCUPANCY IS NIGHTCLUBS, | | | RESTAURANTS, ETC | | | | | | TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA | | | TUS.ASPX FOR PERMIT STATUS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-12-23 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-23 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-19 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2014-12-23 09:08:57 | 12/23/2014 | | | PROJECT: 533 CLEMATIS | | | PERMIT#: 14100819 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: APPROVED WITH EXCEPTION | | | | | | 1) PROVIDE AS BUILT WITH AN ELECTRICAL LIGHTING PLANS | | | INDICATING THE DUAL VOTAGE EMERGENCY AND EXIT LIGHTING | | | FOR THE REQUIRED ILLUMINATED MEANS OF EGRESS, | | | STAIRWARYS, LIGHTING FOR ELECTRICAL PANELS, TASK | | | LIGHTING, AND GENERAL LIGHTING. INDICATE HOW CIRCUITRY | | | IS INSTALLED FOR CONTROL OF NEW AND EXISTING LIGHTING. | | | INDICATE WHAT IS EXISTING TO REMAIN AND WHAT IS | | | PROPOSED TO BE NEW. NEC 700.16, 700.12(F), NFPA 101 | | | 7.8.1.1* | | | | | | SEPARATE PERMIT APPLICATIONS ACCOMPANIED BY | | | MANUFACTURERS EQUIPMENT SUBMITTALS, AND SHOP DRAWINGS | | | ARE REQUIRED FOR SITE LIGHTING, GENERATORS. HOOD | | | EXHAUST, FIRE ALARM, ACCESS CONTROL SYSTEM, SECURITY, | | | CCTV, NETWORK, DATA, AND, COMMUNICATION. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-11-26 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-26 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-11-26 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2014-11-26 15:06:31 | 11/26/2014 | | | PROJECT: 533 CLEMATIS | | | PERMIT#: 14100819 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) REVISE PANEL SCHEDULE FOR PANEL KI AND MDP CIRCUITS | | | IN OFFICE AS BATHROOM AND LOAD CALCULATION AND THERE IS | | | NO CIRCUIT IN MDP INDICATED FOR SUB-PANEL K2.. EVERY | | | CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY | | | IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC | | | PURPOSE OR USE. NEC 408.4 REVISE PANEL SCHEDULE AND | | | LOAD CALCULATION FOR PANEL MDP. | | | | | | 2) REVISE RISER DIAGRAM FOR CLARITY AND ACCURACY. THE | | | RISER DIAGRAM INDICATE A 250AMP PANEL K1 BEING FED FROM | | | PANEL MDP WITH 4, #4/0 AND 1,#8 #6 AND A 225AMP PANEL | | | K2 BEING FED FROM PANEL MDP WITH 4,#3 AND 1,#8. NONE OF | | | THIS IS ADAQUATE TO SUPPORT THE LOAD PROPOSED TO BE | | | FED. NEC 310.16 | | | | | | 3) CLARIFY THE SCOPE OF WORK. THE DESCRIPTION OF WORK | | | ON THE APPLICATION AND ON THE PLAN ARE CONFLICTING. | | | CLARIFY WHAT THE ACTUAL SCOPE OF WORK IS AND WHAT IS | | | EXISTING TO REMAIN, WHAT IS PROPOSED TO RENOVATED AND | | | WHAT IS TO BE INSTALLED NEW. | | | | | | 4) THE RISER DIAGRAM ON SHEET 2.1E STATES "ALL APNELS | | | AND SERVICES ARE EXISTING" YET THE RISER DIAGRAM ITSELF | | | INDICATES A NEW SERVICE FOR THE RESTAURANT. A NEW | | | 400AMP MAIN, FEEDER MDP, K1 & K2, | | | | | | 5) THERE IS REFERENCE TO NOTES ON SHEET 2.1E BUT THERE | | | ARE NO NOTES. THERE ARE ALSO TWO SHEETS #2.1E CLARIFY. | | | | | | 6) THERE IS A REFLECTED CEILING PLAN BUT THERE IS NO | | | ELECTRICAL LIGHTING PLAN. PROVIDE ELECTRICAL LIGHTING | | | PLANS INDICATING HOW THE LIGHTING IS PROPOSED TO BE | | | CONTROLED. CLARIFY | | | | | | THERE IS A NOTE ON SHEET 2.1E THAT STATES | | | "RECIRCULATING PUMPS CEILING SPACE MOUNTED" BUT THERE | | | IS NO CIRCUITRY OR CONTROLS INVOLOVING ANY | | | RECIRCULATING PUMPS. CLARIFY. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-12-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-12-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-12-16 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2014-12-16 12:11:01 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE FOLLOWING COMMENTS HAVE BEEN RE-COMMENTED FROM THE | | | FIRST REVIEW DUE TO A CLOUDED STATEMENT ON THE FIRST | | | SHEET "KEY PLAN" THAT STATES "THIS SPACE SHALL BE | | | SPRINKLERED UNDER THIS PERMIT" ALL FIRE ALARM AND FIRE | | | SPRINKLER WORK SHALL BE SUBMITTED AND APPROVED THROUGH | | | SEPARATE SHOP DRAWINGS. | | | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE | | | FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND | | | COMPLIANCE. | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-10-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-10-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-10-29 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2014-10-29 14:02:22 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE | | | FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND | | | COMPLIANCE. | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-10-27 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-10-27 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-10-27 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-12-23 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-23 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-15 |
Time |
18:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-11-26 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-11-26 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-27 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-12-19 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-12-19 |
Time |
05:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-12-19 |
Time |
04:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-11-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-11-02 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-11-02 |
Time |
08:42 |
Sent To |
|
|
| Notes |
| 2014-11-02 08:49:27 | 1) THE KEY PLAN NOTES THAT THE RESTROOMS AND KITCHEN | | | ARE EXISTING TO REMAIN YET THE LEGEND ON SHT.1.0A SHOWS | | | THE PARTITIONS AROUND THE RESTROOM AND KITCHEN AS NEW. | | | CLARIFY. | | | 2) SHT.3.0A SHOWS NEW PLUMBING THROUGHOUT THE AREA | | | TYING INTO THE EXISTING. CLARIFY. THIS SHEET ALSO HAS | | | NOTES THAT READ "SEE DETAIL 19" & CIRCLED NUMBERS THAT | | | REFER TO DEMOLITION NOTES. AND THERE ARE NO DEMOLITION | | | NOTES OR NUMBER NOTES ON THIS SHEET. CLARIFY. | | | WPB AMEND. TO FBC SEC. 107.2.1. | | | 3) SHT. 1.1A - INDICATE THE CONNECTION POINT OF THE | | | "NEW PLUMBING" TO THE EXISTING SYSTEM (SANITARY OR | | | GREASE). WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
|