| Plan Review Stops For Permit 14100612 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-01-21 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-01-21 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
|
Date |
2015-01-21 |
Time |
12:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-01-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-06 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-01-06 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2015-01-06 15:17:55 | BUILDING PLAN REVIEW | | | REVISION: 14100612 | | | PERMIT: 13120617 | | | ADD: 2905 45TH ST. | | | CONT: GEORGE & ASSOCIATES CONTRACTORS, INC. | | | TEL: (772)332-3675 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: TUES.JAN. 06/2015 | | | ACTION: DENIED | | | | | | 1) THE COVER SHEET STILL SHOWS A SWING DOOR ON THE | | | PRIVATE DOOR # 208. 2010 FBC-B 1014.2 EGRESS THROUGH | | | INTERVENING SPACES. EGRESS THROUGH INTERVENING SPACES | | | SHALL COMPLY WITH THIS SECTION. (2) AN EXIT ACCESS | | | SHALL NOT PASS THROUGH A ROOM THAT CAN BE LOCKED TO | | | PREVENT EGRESS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-12-04 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2014-12-04 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-04 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2014-12-04 11:27:49 | BUILDING PLAN REVIEW | | | REVISION: 14100612 | | | PERMIT: 13120617 | | | ADD: 2905 45TH ST. | | | CONT: GEORGE & ASSOCIATES CONTRACTORS, INC. | | | TEL: (772)332-3675 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: THURS. DEC. 04/2014 | | | ACTION: DENIED | | | | | | 1) 2ND REQUEST. SHEET A2.1 2010 FBC-B 1014.2 EGRESS | | | THROUGH INTERVENING SPACES. EGRESS THROUGH INTERVENING | | | SPACES SHALL COMPLY WITH THIS SECTION. (2) AN EXIT | | | ACCESS SHALL NOT PASS THROUGH A ROOM THAT CAN BE LOCKED | | | TO PREVENT EGRESS. | | | | | | 2) 2ND REQUEST. SHEET A2.1. CORRIDOR 205 HAS A RAMP UP | | | TO UPPER PORTION OF FLOOR, THE LATCH SIDE OF DOOR 206 | | | IS LESS THAN 24 INCHES FROM THE EDGE OF THE RAMP. PLESE | | | SEE 2010 FL. ACC. CODE FIGURE 404.2.4.1 (J) LATCH | | | APPROACH LATCH SIDE. | | | | | | 3) 2ND REQUEST WILL NEED TO COMPLY. SHEET A2.1 NEW WALL | | | WILL BE REQUIRED( SEE COMMENT # 1) CONNECTING THE | | | CORRIDOR TO THE LOCKER ROOM AND DOOR 209. IF THIS IS TO | | | BE AN EXTENSION OF THE CORRIDOR THE MINIMUM WIDTH OF | | | THE CORRIDOR WOULD HAVE TO BE 48" SEE FL ACC. CODE | | | FIGURE 404.2.4.1 (G). CAN NOT EGRESS THROUGH LOCKABLE | | | DOORS.1014.2(2) 2. AN EXIT ACCESS SHALL NOT PASS | | | THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS. | | | | | | 4)2ND REQUEST, MISSING SHEETS A3.0 & S2.0 THESE SHEETS | | | WERE IN THE LAST SET OF REVISION DRAWINGS. SHEET A3.0 | | | DETAIL # 6 RAMP SECTION ALSO INDICATES THE CUTTING OF | | | THE CEILING FRAMING MEMBERS TO GAIN HEIGHT IN THIS | | | AREA. WHAT TYPE OF FRAMING MENBERS ARE THEY AND HOW | | | WILL THE MODIFICATION BE MADE? IDENITFY THE TOP OF | | | FRAMING THAT HAS TO BE MODIFIED. 2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA | | | TUS.ASPX FOR PERMIT STATUS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-11-06 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2014-11-06 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-11-06 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2014-11-06 17:21:30 | BUILDING PLAN REVIEW | | | REVISION: 14100612 | | | PERMIT: 13120617 | | | ADD: 2905 45TH ST. | | | CONT: GEORGE & ASSOCIATES CONTRACTORS, INC. | | | TEL: (772)332-3675 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. NOV. 06/2014 | | | ACTION: DENIED | | | | | | 1) SHEET A2.1 LEFT SIDE OF PAGE ROOMS 206, 207 & 208 | | | ARE RED LINED AS TO A DIFFERENT LOCATION AS SHOWN ON | | | PLANS. THEY ARE NOT SIGNED NOR DATED BY THE DESINGNER | | | OF RECORD AS A CHANGE OF LOCATION. 107.2.1.3 ADDITIONAL | | | INFORMATION. PLEASE PROVIDE A LIFE SAFETY PLAN FOR THE | | | AREA BEING RECONFIGURED IT APPEARS THE EGRESS TO | | | ENCLOSED STAIRWELL IS GOING THROUGH ADJOINING ROOMS | | | THAT ARE LOCKABLE. | | | | | | 2010 FBC-B 1014.2 EGRESS THROUGH INTERVENING SPACES. | | | EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH | | | THIS SECTION. (2) AN EXIT ACCESS SHALL NOT PASS THROUGH | | | A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS. | | | | | | 2) SHEET A2.1. CORRIDOR 205 HAS A RAMP UP TO UPPER | | | PORTION OF FLOOR, THE LATCH SIDE OF DOOR 206 IS LESS | | | THAN 24 INCHES FROM THE EDGE OF THE RAMP. PLESE SEE | | | 2010 FL. ACC. CODE FIGURE 404.2.4.1 (J) LATCH APPROACH | | | LATCH SIDE. | | | | | | 3) SHEET A2.1 THE RED LINED PLANS APPEAR TO HAVE A NEW | | | WALL CONNECTING THE CORRIDOR TO THE LOCKER ROOM AND | | | DOOR 209. IF THIS IS TO BE AN EXTENSION OF THE CORRIDOR | | | THE MINIMUM WIDTH OF THE CORRIDOR WOULD HAVE TO BE 48" | | | SEE FL ACC. CODE FIGURE 404.2.4.1 (G). | | | | | | 4) SHEET A3.0 DETAIL # 6 RAMP SECTION ALSO INDICATES | | | THE CUTTING OF THE CEILING FRAMING MEMBERS TO GAIN | | | HEIGHT IN THIS AREA. WHAT TYPE OF FRAMING MENBERS ARE | | | THEY AND HOW WILL THE MODIFICATION BE MADE? IDENITFY | | | THE TOP OF FRAMING THAT HAS TO BE MODIFIED. 2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, ADMINISTRATION 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA | | | TUS.ASPX FOR PERMIT STATUS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2015-01-22 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-01-22 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-01-22 |
Time |
10:37 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-01-06 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2015-01-06 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2015-01-06 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-12-23 |
|
|
Cont ID |
|
| Sent By |
RLECKY |
Date |
2014-12-23 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-23 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-10-21 |
|
|
Cont ID |
|
| Sent By |
SKENNEDY |
Date |
2014-10-21 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-10-21 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-01-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-01-16 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2014-12-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-12-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-12-31 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2014-12-31 14:20:14 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE PREVIOUS COMMENTS FROM FIRE PREVENTION HAVE NOT | | | BEEN ADDRESSED. | | | | | | EXITING THROUGH PRIVATE ROOM 208 IS NOT APPROVED. THE | | | EXIT HALLWAY/CORRIDOR SHALL BE CONTINUED TO THE LOCKER | | | ROOM DOOR. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2014-11-25 |
|
|
Cont ID |
|
| Sent By |
PLEDUC |
Date |
2014-11-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-11-25 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2014-11-25 12:24:46 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE PREVIOUS COMMENTS FROM FIRE PREVENTION HAVE NOT | | | BEEN ADDRESSED. | | | | | | EXITING THROUGH PRIVATE ROOM 208 IS NOT APPROVED. THE | | | HALLWAY SHALL BE CONTINUED TO THE LOCKER ROOM DOOR. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-10-23 |
|
|
Cont ID |
|
| Sent By |
WJOLIN |
Date |
2014-10-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-10-23 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2014-10-23 16:59:19 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | A LIFE SAFETY PLAN WAS NOT SUBMITTED WITH THIS PLAN. | | | THE LIFE SAFETY PLAN SHALL INCLUDE THE OCCUPANCY LOADS, | | | EXIT PATHS WITH OCCUPANY LOADS, TRAVEL DISTANCES, ALL | | | EXIT SIGNS, EXITS, EMERGENCY LIGHTS, FIRE EXTIGUISHER | | | LOCATIONS. IT IS EXTREMELY IMPORTANT TO KNOW AND | | | UNDERSTAND HOW PEOPLE AND HOW MANY PEOPLE WILL BE USING | | | EACH EXIT AND GETTING OUT OF THIS MEZZANINE SPACE IN | | | THE EVENT OF A FIRE. | | | | | | SHEET A 2-1, THE PROPOSED REAR EXITING THROUGH PRIVATE | | | ROOM 208 IS NOT APPROVED. THE 4'6" CORRIDOR SHALL BE | | | CONTINUED TO THE LOCKER ROOM DOOR. IT IS RECOMMENDED | | | THAT THE ROOMS BE SHIFTED TO ALLOW THIS HALLWAY | | | CONFIGUATION. (AS HAND DRAWN ON ONE OF SHEET PLANS) | | | | | | SHEET CRV UNDER GENERAL NOTES, REFERENCE SHALL BE MADE | | | THAT A FIRE ALRM IS REQUIRED AND FOR THE FUTURE | | | SUBMITTAL SHOP DRAWINGS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-01-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-23 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-12 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-01-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-06 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-30 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2014-12-30 14:07:55 | SENT TO B17 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-12-30 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-12-30 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-11-21 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-11-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-06 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-10-20 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2014-10-20 17:52:02 | REVISION SENT TO B13 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2015-01-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-01-22 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-01-22 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2014-12-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-12-30 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-12-30 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-12-30 |
|
|
Cont ID |
|
| Sent By |
HMOSER |
Date |
2014-12-30 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-12-30 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2014-12-30 11:20:10 | PREVIOUSLY PASSED BY HMOSER. APPLICANT NEEDS TO INSERT | | | APPROVED PAGES INTO RE-SUBMITTAL. SAK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-11-04 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2014-11-04 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-11-04 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2015-01-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-23 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-23 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2015-01-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-01-05 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-05 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-11-27 |
|
|
Cont ID |
|
| Sent By |
TKLARGE |
Date |
2014-11-27 |
Time |
03:45 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-11-27 |
Time |
07:43 |
Sent To |
|
|
| Notes |
| 2014-11-27 07:52:48 | 1) THE SHOWER SHALL BE HANDICAPPED ACCESSIBLE PER THE | | | 2010 FL. ACCESSIBILITY CODE SECS. 213.3.6 & 608 , | | | 309.4. SUBMIT ALL DETAILS. 2ND REQUEST. | | | 2) SHT. P0-1 - SECTION 905.3 2010 FPC - VENT CONNECTION | | | TO DRAINAGE SYSTEM - EVERY DRY VENT CONNECTING TO A | | | HORIZONTAL DRAIN SHALL CONNECT ABOVE THE CENTERLINE OF | | | THE HORIZONTAL DRAIN PIPE. 2ND REQUEST. | | | 3) SIZE THE VENT FOR THE SHOWER ON THE PLAN.COMPLY | | | W/FPC SEC.916.1 & TABLE 906.1 OF THE 2010 FPC.2ND | | | REQUEST. | | | 4) MEP PLANS SHALL BE SIGNED & SEALED BY THE DESIGN | | | PROFESSIONAL OF RECORD PER THE FL. ADMIN. CODE RULE | | | 61G15-23.001 & 23.002. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-11-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-11-01 |
Time |
04:41 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-11-01 |
Time |
04:32 |
Sent To |
|
|
| Notes |
| 2014-11-01 04:41:28 | 1) THE SHOWER SHALL BE HANDICAPPED ACCESSIBLE PER THE | | | 2010 FL. ACCESSIBILITY CODE SECS. 213.3.6 & 608 , | | | 309.4. SUBMIT ALL DETAILS. | | | 2) SHT. P0-1 - SECTION 905.3 2010 FPC - VENT CONNECTION | | | TO DRAINAGE SYSTEM - EVERY DRY VENT CONNECTING TO A | | | HORIZONTAL DRAIN SHALL CONNECT ABOVE THE CENTERLINE OF | | | THE HORIZONTAL DRAIN PIPE. | | | 3) SIZE THE VENT FOR THE SHOWER ON THE PLAN.COMPLY | | | W/FPC SEC.916.1 & TABLE 906.1 OF THE 2010 FPC. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|