Plan Review Details - Permit 14100563
Plan Review Stops For Permit 14100563
Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2014-11-20 Cont ID  
Sent By cranford Date 2014-11-20 Time 12:31 Rev Time 0.00
Received By cranford Date 2014-11-20 Time 12:31 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2014-10-23 Cont ID  
Sent By cranford Date 2014-10-23 Time 14:42 Rev Time 0.00
Received By cranford Date 2014-10-23 Time 14:36 Sent To M
Notes
2014-10-23 14:42:08A LOCATION MAP IS NEEDED TO SHOW WHERE WITHIN THE
 FACILITY THE BUILDING IS PROPOSED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-10-31 Cont ID  
Sent By wjolin Date 2014-10-31 Time 13:56 Rev Time 0.00
Received By wjolin Date 2014-10-21 Time 15:34 Sent To  
Notes
2014-10-21 16:10:546651 NORTH JOG ROAD - FIRE PUMPS AND CONTROLLERS
 PERMIT #14100563
 MASTER #13080231
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 DRAWINGS INDICATE AN ADDRESS OF 6701 NORTH JOG ROAD
 (MAINTENANCE BLDG). ADDRESS SHOULD BE 6651 NORTH JOG
 ROAD (POWER BLOCK BLDG).
  
 DRAWING 700-FP-113: DETAIL #6 - PIPING ELEVATIONS,
 VERIFY 100-INCHES (10 PIPE DIAMETERS) BETWEEN PUMPS'
 SUCTION FLANGES AND ADJACENT SUCTION PIPE ELBOW OR TEE
 FITTINGS. (PER NFPA 20 SECTION 5.14.6.3.2, THE DISTANCE
 OF THE FIRE PUMP SUCTION FLANGE AND ANY ADJACENT
 SUCTION PIPE ELBOW/TEE FLANGE SHALL BE SEPARATED BY AT
 LEAST 10 PIPE DIAMETERS WHEN THE ELBOW/TEE HAS A
 CENTERLINE PLANE PARALLEL TO A HORIZONTAL SPLIT-CASE
 PUMP SHAFT.)
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-11-20 Cont ID  
Sent By skennedy Date 2014-11-20 Time 14:35 Rev Time 0.00
Received By skennedy Date 2014-11-19 Time 11:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-11-19 Cont ID  
Sent By cpuell Date 2014-11-19 Time 08:08 Rev Time 0.00
Received By cpuell Date 2014-10-21 Time 14:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-11-03 Cont ID  
Sent By hmoser Date 2014-11-03 Time 10:09 Rev Time 0.00
Received By hmoser Date 2014-11-03 Time 09:16 Sent To  
Notes
2014-11-03 10:08:54PLAN PASS
 THE FOLLOWING ITEMS ARE NOT INCLUDED IN THE SCOPE
 OF THIS PLAN REVIEW. SEPARATE APPLICATION,PLANS,PERMIT
 AND REVIEW ARE REQUIRED FOR, DIESEL FUEL TANKS AND
 DIESEL FUEL PIPING.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2014-11-20 Cont ID  
Sent By skennedy Date 2014-11-20 Time 14:35 Rev Time 0.00
Received By skennedy Date 2014-11-19 Time 16:43 Sent To  
Notes
***NONE***