Plan Review Details - Permit 14100358
| Plan Review Stops For Permit 14100358 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-10-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-10-23 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-10-23 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2014-10-23 13:42:43 | 14100358 | | | 600 OKEECHOBEE BLVD. | | | TEMPORARY SERVICE REVISION | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | SHOW LOCATION ON SITE PLAN FOR THE FIRE PUMP AND | | | FEEDERS. VERIFY THAT ALL FEEDERS ARE RATED AT 125% OF | | | THE FULL LOAD CURRENTS. NEC 695.6 | | | | | | PROVIDE SPECIFICATIONS ON THE FIRE PUMP CONTROLLER AND | | | DISCONNECT. VERIFY THAT THE FIRE PUMP MAIN DISCONNECT | | | IS SERVICE RATED. NEC 695.4 | | | | | | VERIFY THAT SERVICE AND CIRCUIT CONDUCTORS ARE | | | PROTECTED. NEC 695.6 | | | | | | VERIFY THAT THE DISCONNECTING MEANS IS MARKED AND | | | SUPERVISED IN THE CLOSED POSITON OR LOCKED IN THE | | | CLOSED POSITION. NEC 695.4 | | | | | | | | | ROBERT LECKY, CBO | | | ELECTRICAL PLANS REVIEW | | | 561-373-3701 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-10-21 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-10-21 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-10-16 |
Time |
15:25 |
Sent To |
E |
|
| Notes |
| 2014-10-17 16:37:53 | 600 OKEECHOBEE BOULEVARD | | | TRACKING #14100358 | | | PERMIT #14090274 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NO ADDRESS PROVIDED IN TITLEBLOCK INFORMATION. | | | | | | NO AUTOMATIC TRANSFER SWITCH PROVIDED WITH FIRE PUMP | | | CONTROLLER. | | | | | | NO JOCKEP PUMP OR CONTROLLER PROVIDED TO PREVENT FIRE | | | PUMP FROM CYCLING ON/OFF. | | | | | | WHERE IS THE SECONDARY POWER SUPPLY TO THE FIRE PUMP | | | AND CONTROLLERS? | | | | | | HOW WILL THE FIRE PUMP CONDUCTORS BE PROTECTED? | | | CONCRETE ENCASEMENT? | | | | | | FIRE PUMP, CONTROLLERS AND EQUIPMENT INSTALLATION WILL | | | NEED TO COMPLY WITH NFPA 20 (DRAINAGE, LIGHTING, | | | EMERGENCY LIGHTING, FIRE-RATED ENCLOSURE) AND BE | | | INSPECTED, TESTED AND APPROVED WITH THE FIRE DEPARTMENT | | | PRIOR TO PERMANENT OR TEMPORARY USAGE. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-10-23 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-10-23 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-10-10 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2014-10-10 13:50:50 | INCOMING SENT TO FIRE BOX. JW |
|
|
|