Plan Review Details - Permit 14100350
Plan Review Stops For Permit 14100350
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-12-15 Cont ID  
Sent By jwitmer Date 2014-12-15 Time 09:30 Rev Time 0.00
Received By jwitmer Date 2014-12-15 Time 07:45 Sent To  
Notes
2014-12-15 09:04:12BUILDING PLAN REVIEW
 PERMIT: 14100350
 ADD: 10130 NORTHLAKE BLVD.
 CONT: HAWKINS
 TEL: (305-796-9695
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. DEC. 15/2014
 ACTION: BUILDING PROVISO
  
 1) COMPLIED.
  
 2) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.3.4.2.
 DEFERRED SUBMITTAL:
 FL 17337 IS PENDING APPROVAL. PLEASE CIRCLE WHICH
 SUB-SYSTEM WILL BE INSTALLED (4) SUB-SYSTEMS. 2010
 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF
 PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE
 PRODUCT APPROVALS:
 (31)(B) WINDOWS.
  
 3) 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 107.3.4.2.
 DEFERRED SUBMITTAL:
 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 4) PROVISO, A REVISION MAY BE REQUIRED: SHEET A11
 DETAILS B2 & B4 BOTH DELETED THE DRAWER UNIT BENEATH
 THE WINDOW. THIS NOW ONLY BECOMES A FIXED WINDOW. IF A
 AUDIO AND DRAWER UNIT IS TO MAKE THIS A DRIVE UP UNIT
 THEN A REVISION WILL BE REQUIRED FOR THIS UNIT AND A
 NEW STRUCTURAL SHEET OF HOW THE WINDOW SILL WILL BE
 AFFECTED.
  
 5-6) COMPLIED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-11-06 Cont ID  
Sent By jwitmer Date 2014-11-06 Time 10:34 Rev Time 0.00
Received By jwitmer Date 2014-11-06 Time 08:41 Sent To  
Notes
2014-11-06 09:45:29BUILDING PLAN REVIEW
 PERMIT: 14100350
 ADD: 10130 NORTHLAKE BLVD.
 CONT: HAWKINS
 TEL: (305-796-9695
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. NOV. 06/2014
 ACTION: DENIED
  
 1) SHEET D-1, A-1 & S-3 ALL SHOW A NEW WALK-UP/
 DRIVE-UP WINDOW. THE S-3 SHEET PROVIDES THE WIND DESIGN
 CRITERIA BUT NOT THE PRESSUES ASSOCIATED WITH THE NEW
 EXTERIOR WALL OPENING. THE A-11 SHEET SHOWS PRESSURES
 OF +36/ -39, BUT THERE IS NO WIND DESIGN CRITERIA FOR
 THE DESIN OF THESE PRESSUES, ARE THEY VULT OR VASD,
 WHAT EXPOSURE, HEIGHT ADJUSTMENT FACTORS????? PLEASE
 PROVIDE THE PRESSURES FOR THE NEW OPENING. COMPONENTS &
 CLADDING PRESSURES POSITVE & NEGATIVE TABLE 1609.2(2) .
  
 2) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.41 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(B) WINDOWS
  
 3) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 4) SHEET A11 DETAILS B2 & B4 BOTH INDICATE THE NEW
 PHARMACY WINDOW TO BE A FIXED WINDOW A YKK NOA
 05-0301.06. THIS MIAMI-DADE REPORT EXPIRED ON
 06/16/2010. THERE IS A DISCREPANCY BETWEEN THIS SHEET
 AND A-1. SHEET A-1 INDICATES THE NEW WINDOW IS TO BE A
 COMBINATION WINDOW/ COMMERCIAL DRAWER UNIT, E. F. BAVIS
 AUTOEYOR UNIT WITH AUDIO FOR THE HEARING IMPAIRED.
 DISCREPANCY IN PLANS, NOTE WITH THIS UNIT THE WINDOW
 ILL BE LOWER THAN DRAWN ON SHEET A11/ DETAIL B4. 2010
 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 5) THE PLANS DO NOT PROVIDE ANY DETAILS SHOWING THE
 CHECK OUT COUNTERS COMPLY WITH 2010 FL ACCESS. CODE
 904.3.
  
 6) SHEET A-6 SHOWS INTERIOR ELEVATIONS BUT AGAIN THE
 PLANS DO NOT SHOW COMPLIANCE WITH 2010 FL ACCESS. CODE
 904.3.3 & 904.3.4 CHECK WRITING SURFACES & SALES AND
 SERVICE COUNTERS.
  
  
 TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO
 HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA
 TUS.ASPX FOR PERMIT STATUS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-10-14 Cont ID  
Sent By rlecky Date 2014-10-14 Time 11:36 Rev Time 0.00
Received By rlecky Date 2014-10-14 Time 10:25 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-10-17 Cont ID  
Sent By pleduc Date 2014-10-17 Time   Rev Time 0.00
Received By pleduc Date 2014-10-16 Time 08:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-12-17 Cont ID  
Sent By tklarge Date 2014-12-17 Time 06:17 Rev Time 0.00
Received By tklarge Date 2014-12-09 Time   Sent To  
Notes
2014-12-10 16:12:50INCOMING SENT TO C26.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-11-06 Cont ID  
Sent By jwitmer Date 2014-11-06 Time 10:34 Rev Time 0.00
Received By jwitmer Date 2014-10-10 Time 14:01 Sent To  
Notes
2014-10-10 14:02:02INCOMING SENT TO C-27 BOX. JW

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2014-11-06 Cont ID  
Sent By jwitmer Date 2014-11-06 Time 09:42 Rev Time 0.00
Received By jwitmer Date 2014-11-06 Time 09:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-10-28 Cont ID  
Sent By hmoser Date 2014-10-28 Time 10:45 Rev Time 0.00
Received By hmoser Date 2014-10-27 Time 15:28 Sent To  
Notes
2014-10-28 09:20:04PASS PROVISO
  
 1) REFER TO SECTION 606.3 INSTALLATION (ACCESS DOORS
 FOR DUCT DETECTORS) 2010 FBC (M)
  
 2) HOODS, FIRE SUPPRESSION AND REFRIGERATION
 ARE NOT INCLUDED IN THIS REVIEW. SEPARATE
 APPLICATION, PLAN AND PERMITS REQUIRED.
 PER SECTION 107 FBC 2010
 3) PROVIDE AUTOMATIC DAMPERS ON
 OUTDOOR AIR AND EXHAUST. PER
 SECTION 503.2.4.4 SHUTOFF DAMPER
 CONTROLS 2010 FLORIDA ENERGY CODE.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2014-12-17 Cont ID  
Sent By tklarge Date 2014-12-17 Time 06:17 Rev Time 0.00
Received By tklarge Date 2014-12-17 Time 05:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-10-30 Cont ID  
Sent By tklarge Date 2014-10-30 Time 08:53 Rev Time 0.00
Received By tklarge Date 2014-10-30 Time 08:31 Sent To  
Notes
2014-10-30 08:53:211) SUBMIT DRAWINGS FOR THE PNEEUMATIC TUBE SYSTEM AT
 THE DRIVE THROUGH IF THAT IS BEING REPLACED. WPB AMEND.
 TO 2010 FBC SEC. 107.2.1.
 2) SHT. A-3 - THERE ARE VTR'S THAT APPEAR TO BE WITHIN
 10 FT. OF THE ROOF TOP UNITS AC-1, AC-2, AC-3. IF THE
 UNITS HAVE INTAKE/MAKEUP AIR CAPABILITIES THE VENTS
 SHALL COMPLY W/ 2010 FPC SEC.904.5.
 3) SHT. P-3 - THE CONDENSATE DRAINS CANNOT DISCHARGE TO
 THE SANITARY SYSTYM PER CITY ORD. SEC. 90-126.
 4) CLEAR WATER WASTE 9CONDENSATE) SHALL NOT DISCHARGE
 TO THE GREASY WASTE SYSTEM PER THE 2010 FPC SEC.1003.2.
 5) SIZE THE HOT AND COLD WATER LINES TO THE EMPLOYEE
 RESTROOM FIXTURES. THE JANITOR SINK IS NOT SHOWN ON THE
 WATER RISER. WPB AMEND. TO 2010 FBC SEC. 107.2.1.
 6) SUBMIT MANUF. SPECIFICATIONS/INSTALLATION
 INSTRUCTIONS FOR TANKLESS WATER HEATER. WPB AMEND. TO
 2010 FBC SEC. 107.2.1.
 7) SUBMIT A GAS RISER DIAGRAM FOR ANY CHANGES TO THE
 GAS SYSTEM.WPB AMEND. TO 2010 FBC SEC. 107.2.1.
 INDICATE ON SHT.P-4 IF THE LP GAS TANK & PIPING IS NEW
 OR EXISTING. IF NEW, SUBMIT A GAS RISER FOR THIS
 INSTALLATION.WPB AMEND. TO 2010 FBC SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status P Date 2015-02-27 Cont ID  
Sent By dkittred Date 2015-02-27 Time 09:34 Rev Time 0.00
Received By dkittred Date 2015-02-27 Time 09:32 Sent To  
Notes
2015-02-27 09:33:572/27/15 - MINOR PD AMENDMENT FOR DRIVE-THRU (PB 993
 YYYYY) WAS APPROVED BY PLANNING AND ZONING. DK

Review Stop Z ZONING
Rev No 2 Status F Date 2014-12-11 Cont ID  
Sent By dkittred Date 2014-12-11 Time 11:06 Rev Time 0.00
Received By dkittred Date 2014-12-11 Time 10:46 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2014-10-20 Cont ID  
Sent By dkittred Date 2014-10-20 Time 10:32 Rev Time 0.00
Received By dkittred Date 2014-10-20 Time 10:02 Sent To  
Notes
2014-10-20 10:31:57PLANNING AND ZONING COMMENTS: ***FAILED***
  
 10/20/14
  
 1. SITE PLAN SHOWS CONVERSION OF CUSTOMER
 DROP-OFF/PICK-UP AREA TO A PHARMACY DRIVE THRU-LANE.
 THIS CHANGE REQUIRE A MINOR PLANNED DEVELOPMENT (PD)
 AMENDMENT APPLICATION BE SUBMITTED THROUGH THE PLANNING
 AND ZONING DIVISION FOR REVIEW AND APPROVAL PRIOR TO
 ZONING APPROVAL OF THIS BUILDING PERMIT. THE
 APPLICATION CAN BE FOUND AT: HTTP://WPB.ORG/PLANNING/WP
 -CONTENT/UPLOADS/SITES/37/2014/05/2014-DEVELOPMENT-APPL
 ICATION-REVISED-05.20.2014.PDF
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  
2014-10-15 13:08:0610/15/14