| Plan Review Stops For Permit 14100349 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-03-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-03-14 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-03-14 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2015-03-14 13:06:20 | ****PROVISO**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | ****COPY OF CONTRACT REQUIRED PRIOR TO FIRST | | | INSPECTION**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. REVISE LIGHT POLE CALCS. THIS LOCATION HAS A WIND | | | SPEED OF 167MPH FOR RISK CATEGORY II, 150MPH FOR RISK | | | CATEGORY I. ENGINEER HAS DESIGNED TO RISK CATEGORY II, | | | 160MPH. REVISE CALCS ACCORDINGLY, FBC 1609. | | | | | | 2. PROVIDE A COPY OF THE CONTRACT PRIOR TO FIRST | | | INSPECTION. CONTRACT TO BE SENT VIA EMAIL TO | | | [email protected]. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2015-02-17 |
|
|
Cont ID |
|
| Sent By |
S. Hill |
Date |
2015-02-17 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-02-17 |
Time |
07:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-12-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-12-15 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-12-15 |
Time |
17:13 |
Sent To |
E |
|
| Notes |
| 2014-12-15 17:23:50 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SHEET P1.0, SEE FAC61G15-23 FOR SEALS ACCEPTABLE TO | | | THE BOARD. SEALS WITH THE WORD "CERTIFICATE" RATHER | | | THAN "LICENSE" HAVE NOT BEEN IN USE FOR SEVERAL YEARS. | | | | | | 2. SEE FAC61G15-23 FOR THE CORRECT FORMAT FOR CALCS | | | (EITHER EITHER SHEET SIGNED/SEALED,OR AN INDEX SHEET | | | USED, AND TITLE BLOCK IS LACKING). YOU CAN SEE THE | | | SECTION AT WWW.FBPE.ORG, LEGAL, FLORIDA ADMINISTRATIVE | | | CODE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-12-30 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-30 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-30 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-10-24 |
|
|
Cont ID |
|
| Sent By |
misc2 |
Date |
2014-10-24 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-24 |
Time |
08:00 |
Sent To |
B |
|
| Notes |
| 2014-10-24 08:24:07 | 10/24/2014 | | | PROJECT: AUTOZONE | | | PERMIT#: 14100349 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE WIND LOAD CALCULATIONS IN ACCORDANCE WITH | | | THE FBC CHAPTERS 26 THROUGH 30 OF ASCE 7 OR THE | | | PROVISIONS OF THE ALTERNATE ALL HEIGHTS METHOD IN THE | | | FBC SECTION 1609.6. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-02-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-02-17 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-30 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-01-30 15:23:45 | SENT TO ZONING BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-12-30 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-30 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-10 |
Time |
08:52 |
Sent To |
Z |
|
| Notes |
| 2014-12-15 17:25:21 | 12/15 TO DAH DESK | | | | | 2014-12-10 08:53:08 | SENT TO LLOUIE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-10-24 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-10-24 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-09 |
Time |
17:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2015-03-13 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2015-03-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2015-03-13 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2015-02-04 |
|
|
Cont ID |
|
| Sent By |
L. Louie |
Date |
2015-02-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2015-02-04 |
Time |
|
Sent To |
B |
|
| Notes |
| 2015-02-04 15:02:56 | ** ZONING FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) CONDITIONS OF ISPR #13-12/Z13120013 HAVE NOT BEEN | | | ADDRESSED. CONDITIONS NEED TO BE ADDRESSED PRIOR TO | | | SUBMITTING FOR BUILDING PERMITS. (REPEAT COMMENT FROM | | | 10/22/14 AND 12/30/14) | | | | | | PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE | | | ARE QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-12-11 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-30 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-12-11 |
Time |
|
Sent To |
E |
|
| Notes |
| 2014-12-11 13:27:00 | ** ZONING FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) CONDITIONS OF ISPR #13-12/Z13120013 HAVE NOT BEEN | | | ADDRESSED. CONDITIONS NEED TO BE ADDRESSED PRIOR TO | | | SUBMITTING FOR BUILDING PERMITS. (REPEAT COMMENT FROM | | | 10/22/14) | | | | | | PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE | | | ARE QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-12-11 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2014-10-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-10-22 |
Time |
|
Sent To |
E |
|
| Notes |
| 2014-10-22 11:18:20 | ** ZONING FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) CONDITIONS OF ISPR #13-12/Z13120013 HAVE NOT BEEN | | | ADDRESSED. CONDITIONS NEED TO BE ADDRESSED PRIOR TO | | | SUBMITTING FOR BUILDING PERMITS. | | | | | | PLEASE CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE | | | ARE QUESTIONS. | | | |
|
|