Plan Review Details - Permit 14100238
Plan Review Stops For Permit 14100238
Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-10-09 Cont ID  
Sent By skennedy Date 2014-10-09 Time 09:23 Rev Time 0.00
Received By skennedy Date   Time   Sent To  
Notes
2014-10-09 08:57:52OBSERVE THESE REQUIREMENTS
  
 M1401.2 ACCESS.
 HEATING AND COOLING EQUIPMENT SHALL BE LOCATED WITH
 RESPECT TO BUILDING CONSTRUCTION AND OTHER EQUIPMENT TO
 PERMIT MAINTENANCE, SERVICING AND REPLACEMENT.
 CLEARANCES SHALL BE MAINTAINED TO PERMIT CLEANING OF
 HEATING AND COOLING SURFACES; REPLACEMENT OF FILTERS,
 BLOWERS, MOTORS, CONTROLS AND VENT CONNECTIONS;
 LUBRICATION OF MOVING PARTS; AND ADJUSTMENTS.
  
 SECTION 306
 ACCESS AND SERVICE SPACE
  
 306.1 ACCESS FOR MAINTENANCE AND REPLACEMENT.
 APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE,
 REPAIR AND REPLACEMENT WITHOUT DISABLING THE FUNCTION
 OF A FIRE-RESISTANCE-RATED ASSEMBLY OR REMOVING
 PERMANENT CONSTRUCTION, OTHER APPLIANCES, VENTING
 SYSTEMS OR ANY OTHER PIPING OR DUCTS NOT CONNECTED TO
 THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED OR
 REPLACED. A LEVEL WORKING SPACE AT LEAST 30 INCHES DEEP
 AND 30 INCHES WIDE (762 MM BY 762 MM) SHALL BE PROVIDED
 IN FRONT OF THE CONTROL SIDE TO SERVICE AN APPLIANCE.
  
 306.1.1 CENTRAL FURNACES.
 CENTRAL FURNACES WITHIN COMPARTMENTS OR ALCOVES SHALL
 HAVE A MINIMUM WORKING SPACE CLEARANCE OF 3 INCHES (76
 MM) ALONG THE SIDES, BACK AND TOP WITH A TOTAL WIDTH OF
 THE ENCLOSING SPACE BEING AT LEAST 12 INCHES (305 MM)
 WIDER THAN THE FURNACE. FURNACES HAVING A FIREBOX OPEN
 TO THE ATMOSPHERE SHALL HAVE AT LEAST 6 INCHES (152 MM)
 WORKING SPACE ALONG THE FRONT COMBUSTION CHAMBER SIDE.
 COMBUSTION AIR OPENINGS AT THE REAR OR SIDE OF THE
 COMPARTMENT SHALL COMPLY WITH THE REQUIREMENTS OF
 CHAPTER 7.
  
 EXCEPTION: THIS SECTION SHALL NOT APPLY TO REPLACEMENT
 APPLIANCES INSTALLED IN EXISTING COMPARTMENTS AND
 ALCOVES WHERE THE WORKING SPACE CLEARANCES ARE IN
 ACCORDANCE WITH THE EQUIPMENT OR APPLIANCE
 MANUFACTURER?S INSTALLATION INSTRUCTIONS.
  
 306.2 APPLIANCES IN ROOMS.
 ROOMS CONTAINING APPLIANCES SHALL BE PROVIDED WITH A
 DOOR AND AN UNOBSTRUCTED PASSAGEWAY MEASURING NOT LESS
 THAN 36 INCHES (914 MM) WIDE AND 80 INCHES (2032 MM)
 HIGH.
  
 EXCEPTION: WITHIN A DWELLING UNIT, APPLIANCES INSTALLED
 IN A COMPARTMENT, ALCOVE, BASEMENT OR SIMILAR SPACE
 SHALL BE ACCESSED BY AN OPENING OR DOOR AND AN
 UNOBSTRUCTED PASSAGEWAY MEASURING NOT LESS THAN 24
 INCHES (610 MM) WIDE AND LARGE ENOUGH TO ALLOW REMOVAL
 OF THE LARGEST APPLIANCE IN THE SPACE, PROVIDED THAT A
 LEVEL SERVICE SPACE OF NOT LESS THAN 30 INCHES (762 MM)
 DEEP AND THE HEIGHT OF THE APPLIANCE, BUT NOT LESS THAN
 30 INCHES (762 MM), IS PRESENT AT THE FRONT OR SERVICE
 SIDE OF THE APPLIANCE WITH THE DOOR OPEN.
  
 306.3 APPLIANCES IN ATTICS.
 ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN
 OPENING AND UNOBSTRUCTED PASSAGEWAY LARGE ENOUGH TO
 ALLOW REMOVAL OF THE LARGEST APPLIANCE. THE PASSAGEWAY
 SHALL NOT BE LESS THAN 30 INCHES (762 MM) HIGH AND 22
 INCHES (559 MM) WIDE AND NOT MORE THAN 6 FEET (1829 MM)
 IN LENGTH MEASURED ALONG THE CENTERLINE OF THE
 PASSAGEWAY FROM THE OPENING TO THE APPLIANCE. THE
 PASSAGEWAY SHALL HAVE CONTINUOUS SOLID FLOORING NOT
 LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE
 SPACE NOT LESS THAN 30 INCHES (762 MM) DEEP AND 30
 INCHES (762 MM) WIDE SHALL BE PRESENT AT THE FRONT OR
 SERVICE SIDE OF THE APPLIANCE. THE CLEAR ACCESS OPENING
 DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY 30 INCHES
 (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW REMOVAL
 OF THE LARGEST APPLIANCE.
  
 EXCEPTION:
  
 THE PASSAGEWAY AND LEVEL SERVICE SPACE ARE NOT REQUIRED
 WHERE THE APPLIANCE IS CAPABLE OF BEING SERVICED AND
 REMOVED THROUGH THE REQUIRED OPENING.
2014-10-07 13:18:23ROUTED TO MECHANICAL LESS THAN $5000

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2014-10-09 Cont ID  
Sent By rbergsma Date 2014-10-09 Time   Rev Time 0.50
Received By rbergsma Date 2014-10-09 Time   Sent To  
Notes
***NONE***