Plan Review Details - Permit 14100194
| Plan Review Stops For Permit 14100194 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-01-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-23 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-01-20 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2015-01-20 11:59:45 | BUILDING PLAN REVIEW | | | PERMIT: 14100194 | | | ADD: 3416 S. DIXIE HWY | | | CONT: JACOB ERECTING | | | TEL: (561)741-1818 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: MON. JAN 20/2015 | | | ACTION: BUILDING PROVISO | | | | | | 1) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING.FLORIDA DEPARTMENT OF | | | COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES NO SUB-SYSTEM | | | HAS BEEN IDENTIFIED, ENHANCED FASTENING WILL BE | | | REQUIRED FOR THE ROOF INSULATION AS WELL AS THE ROOFING | | | SYSTEM, SEE IF LIMITATION #7 OR #9. | | | | | | ONCE THE CONTRACTOR PICKS WHICH ROOFING SUB-SYSTEM IS | | | TO BE APPLIED TO THE ROOF DECK, THE PRODUCT APPROVAL | | | MUST BE REVIEWED BY THE DESIGNER OF RECORD AND SHOP | | | DRAWING STAMP OF APPROVAL APPLIED. RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-12-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-12-18 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-18 |
Time |
07:35 |
Sent To |
|
|
| Notes |
| 2014-12-18 11:15:47 | BUILDING PLAN REVIEW | | | PERMIT: 14100194 | | | ADD: 3416 S. DIXIE HWY | | | CONT: JACOB ERECTING | | | TEL: (561)741-1818 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: THURS. DEC. 18/2014 | | | ACTION: DENIED | | | | | | 1) PLEASE PROVIDE A SITE PLAN WITH THE PROPOSED | | | LOCATION OF THE BUILDING ON THE LOT AND THE DISTANCE | | | FROM PROPERTY LINES. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION,107.3.5 MINIMUM PLAN | | | REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | 1. SITE PLAN & REQUIREMENTS: | | | PARKING : CITY MUNI CODE REQUIRES A DOUBLE STRIPE | | | 94-485. | | | ACCESSIBLE EXITS | | | THE LARGER OF THE 2 TENANTCIES REQUIRES 2 EXITS BECAUSE | | | THE OCCUPANT LOAD IS OVER 50 OCCUPANTS (74 OCCUPANTS). | | | THIS REQUIRES 2 EXITS FBC-B TABLE 1015.1. THE 2010 FBC- | | | ACCESSIBILITY CODE 207.1 REFERS TO THE 2003 IBC-B 1007. | | | 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS | | | IS REQUIRED BY SECTION 1014.1 OR 1018.1 FROM ANY | | | ACCESSIBLE SPACE, EACH ACCESIBLE PORTION OF THE SPACE | | | SHALL BE SERVED BY NOT LESS THAN TWO ACCESSIBLE MEANS | | | OF EGRESS. THE BACK EXIT DOES NOT SHOW AN ACCESIBLE | | | EXIT DISCHARGE, YOU WOULD HAVE TO TRAVEL WITH A | | | WHEELCHAIR BEHIND PARKED CARS THERE IS NO ACCESSIBLE | | | WALKWAY TO TRAVEL ON TO GETTO THE PUBLIC WAY. | | | | | | 2) COMPLIED. SOILS REPORT. | | | | | | 3) COMPLIED. ENERGY CALCULATIONS WERE PROVIDED. | | | | | | 4 2ND REQUEST WIND PRESSURES FOR COMPONENTS AND | | | CLADDING. SHEET S1 LIST THE WIND DESIGN CRITERIA, WITH | | | A C EXPOSURE. THE COMMENT RESPONSE INDICATED THE WINDOW | | | & DOOR PRESSURES COULD NOW BE FOUND ON THE ELEVATION | | | SHEET A-3.0. | | | | | | 4A) THE PRESURES REPRESENTED ON THIS SHEET APPEAR TO BE | | | TAKEN AS A B EXPOSURE AT 15 FT. | | | | | | 4B) THE COMMENT RESPONSE ALSO INDICATED THE ROOFING | | | PRESSURES ARE TO BE FOUND ON SHEET S2.1. THESE | | | PRESSURES ALSO APPEAR TO BE LOW AS TAKEN AS A B | | | EXPOSURE AT 15 FT. PLEASE ALSO NOTE THE PARAPET IS LESS | | | THAN 3 FEET IN HEIGHT WHICH WILL MEAN THERE IS A ROOF | | | CORNER ZONE AND HIGHER ASSOCIATED PRESSURES. THE | | | ELEVATIONS SHOWN ON A-3.0 OF THE BAR JOIST, IS THE | | | JOIST BEARING POINT. THE VERTICAL HEIGHT OF THE BAR | | | JOIST, B-DECK, AND 6 INCHES OF INSULATION (ENERGY | | | CALCS.) PUTS THE APPROX. MEAN FINISH ROOF HEIGHT AT | | | 18FT. 10 INCHES TO 18 FT. 11 IN., THE TOP OF PARAPET IS | | | AT 21 FT. 4 IN. OR LESS THAN 3 FT OF PARAPET. | | | | | | | | | 5) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING.FLORIDA DEPARTMENT OF | | | COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES NO SUB-SYSTEM | | | HAS BEEN IDENTIFIED, ENHANCED FASTENING WILL BE | | | REQUIRED FOR THE ROOF INSULATION AS WELL AS THE ROOFING | | | SYSTEM, SEE IF LIMITATION #7 OR #9. | | | (G) PRE-ENGINEERED A/C STANDS/ ROOF TOP CURBS | | | | | | 5A) WITH ROOF TOP A/C CONDENSORS THE M6.1 INDICATES THE | | | USE OF ROOF TOP CURBS, THERE IS NO FRAMING DETAILS FOR | | | THE ANCHORING OF THE ROOF TOP CURBS, NOR DOES THE PLANS | | | PROVIDE THE AMOUNT OF FASTENERS, AND SIZE OF FASTENERS | | | IT WILL TAKE TO ANCHOR THE CURB TO THE ROOF FRAMING. | | | THE PLANS ALSO WILL NEED TO PROVIDE DETAILS OF THE | | | ANCHORING THE ROOF TOP UNITS TO THE ROOF CURB. | | | | | | 6) ROOFING APPROVAL ONCE THE SUB-SYSTEM IS | | | IDENTIFIED.2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY THE DCA RULE 9N-03 | | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 7-10) COMPLIED. | | | | | | 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA | | | TUS.ASPX FOR PERMIT STATUS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-11-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-07 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-11-07 |
Time |
07:03 |
Sent To |
|
|
| Notes |
| 2014-11-07 09:22:43 | BUILDING PLAN REVIEW | | | PERMIT: 14100194 | | | ADD: 3416 S. DIXIE HWY | | | CONT: JACOB ERECTING | | | TEL: (561)741-1818 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. NOV. 07/2014 | | | ACTION: DENIED | | | | | | 1) PLEASE PROVIDE A SITE PLAN WITH THE PROPOSED | | | LOCATION OF THE BUILDING ON THE LOT AND THE DISTANCE | | | FROM PROPERTY LINES. | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION,107.3.5 MINIMUM PLAN | | | REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | 1. SITE PLAN & REQUIREMENTS: | | | PARKING | | | FIRE ACCESS | | | VEHICLE LOADING | | | DRIVING/TURNING RADIUS | | | FIRE HYDRANT/WATER SUPPLY/POST INDICATOR VALVE (PIV) | | | SET BACK/SEPARATION (ASSUMED PROPERTY LINES) | | | | | | 2) MISSING SOILS REPORT. PLEASE PROVIDE WHAT THE | | | MINIMUM SAFE BEARING VALUE IS. 2010 FBC-B 1803.5.2 | | | QUESTIONABLE SOIL.WHERE THE CLASSIFICATION, STRENGTH OR | | | COMPRESSIBILITY OF THE SOIL IS IN DOUBT OR WHERE A | | | LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS | | | CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL BE | | | PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION | | | BE CONDUCTED. | | | | | | 3) THIS IS A NEW BUILDING BUT NO ENERGY CALCULATIONS | | | WERE PROVIDED. 2010 FBC- ENERGY 103.2/ TABLE 103.2.1 OR | | | 103.2.2.2. | | | | | | 4) MISSING WIND PRESSURES FOR COMPONENTS AND CLADDING. | | | SHEET S1 LIST THE WIND DESIN CRITERIA BUT THE PRESSURES | | | FOR COMPONENTS AND CLADDING ARE MISSING FOR ROOF ZONES | | | 1,2, & 3 AS WELL AS WALL ZONES 4 & 5. | | | | | | 5) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING.FLORIDA DEPARTMENT OF | | | COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 6) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 7) SHEET LS-1.0 INDICATES A 1 HOUR TENANT SEPERATION | | | WALL SEE A-5 DETAIL # 2. PLEASE NOTE THE DETAIL | | | INDICATES FASTENING THE TOP TRACK TO THE ROOF DECK AND | | | TO CAULK BOTH SIDES OF WALL WITH # HW-D-0200. PLEASE | | | PROVIDE INFORMATION ON CAULK. THIS HAS TO BE A FLEXIBLE | | | JOINT BEING A CONNECTION TO DISSIMILAR MATERIALS AND | | | FLEXIBLE SINCE THE ROOF LOADING MAY CHANGE. | | | 2010 FBC-B | | | 714.1 GENERAL. | | | JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE-RATED | | | WALLS, FLOOR OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR | | | ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED BY AN | | | APPROVED FIRE-RESISTANT JOINT SYSTEM DESIGNED TO RESIST | | | THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE | | | REQUIRED FIRE-RESISTANCE RATING OF THE WALL, FLOOR OR | | | ROOF IN OR BETWEEN WHICH IT IS INSTALLED. | | | FIRE-RESISTANT JOINT SYSTEMS SHALL BE TESTED IN | | | ACCORDANCE WITH SECTION 714.3. THE VOID CREATED AT THE | | | INTERSECTION OF A FLOOR/CEILING ASSEMBLY AND AN | | | EXTERIOR CURTAIN WALL ASSEMBLY SHALL BE PROTECTED IN | | | ACCORDANCE WITH SECTION 714.4. | | | | | | 8) SHEET LS-1.0 THE 1-HOUR FIRE SEPARATION WALL WILL | | | NEED LABELING SEEFBC-B 713.6. SUCH IDENTIFICATION SHALL | | | BE ABOVE ANY DECORATIVE CEILING AND IN CONCEALED | | | SPACES. SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: | | | ?FIRE AND SMOKE BARRIER ? PROTECT ALL OPENINGS.? | | | | | | 9) SHEET LS-1.0 THE LARGER OF THE TWO TENANT SPACES | | | REFLECTS A OCCUPANT LOAD > THAN 49 REQUIRING 2 EXITS | | | FBC TABLE 1015.1.). THE REAR EXIT OF THIS SPACE IS A | | | REQUIRED EXIT WITH AN OCCUPANT LOAD APPROX. 81 | | | OCCUPANTS. NOTE THE PLANS INDICATE INSWING DOOR , | | | SECTION FBC-B 1008.1.2 REQUIRES DOORS SHALL SWING IN | | | THE DIRECTION OF EGRESS TRAVEL WHERE SERVING AN | | | OCCUPANT LOAD OF 50 OR MORE PERSONS OR A GROUP H | | | OCCUPANCY. | | | PLEASE ALSO NOTE, NOT HAVING A SITE PLAN EXTERIOR DOORS | | | CAN NOT SWING OVER PROPERTY LINES. FBC-B 3202.2. | | | | | | 10) LS-1.0 THE DESIGNER OF RECORD HAS ELECTED TO DESIGN | | | THIS BUILING AS A IIIA TYPE BUILDING (PROTECTED), | | | PLEASE PROVIDE THE 1 HOUR FIRE RATING OF THE PRIMARY | | | STRUCTURAL FRAME, 2 HR EXTERIOR WALLS SEE FOOTNOTES F & | | | G, AND 1 HOUR FOR ROOF CONSTRUCTION AND SECONDARY | | | MEMBERS. | | | | | | 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 12) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | TO REVIEW PERMIT STATUS OR ALL REVIEWS YOU MAY LOG ONTO | | | HTTP://ONESTOPSHOP.WPBGOV.COM/EGOVPLUS/PERMIT/PERM_STA | | | TUS.ASPX FOR PERMIT STATUS. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-01-29 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-29 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-29 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2015-01-29 16:58:10 | 1/29/2015 | | | PROJECT: NEW RETAIL BUILDING | | | PERMIT#: 14100194 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 3RD ELECTRICAL PLAN REVIEW | | | ACTION: APPROVED WITH EXCEPTION | | | | | | 1) ACCORDING TO THE ENGINEER OF RECORD, THE REQUIRED | | | WIND LOAD CALCULATIONS ARE TO BE PROVIDED BY THE LIGHT | | | POLE MANUFACTURER VIA THE CONTRACTOR. THESE | | | CALCULATIONS SHALL BE PROVIDED TO THE INSPECTOR | | | INSPECTOR ON SITE AND SUBMITTED TO DEVELOPMENT SERVICED | | | DEPT AS A REVISION PRIOR TO FINAL INSPECTION. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2015-01-08 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-01-08 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-01-08 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2015-01-08 16:06:57 | 1/8/2015 | | | PROJECT: NEW RETAIL BUILDING | | | PERMIT#: 14100194 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) 1) 505.2.4 EXTERIOR LIGHTING CONTROLS. | | | LIGHTING FOR ALL EXTERIOR APPLICATIONS NOT EXEMPTED IN | | | SECTION 505.1 SHALL HAVE AUTOMATIC CONTROLS CAPABLE OF | | | TURNING OFF EXTERIOR LIGHTING WHEN SUFFICIENT DAYLIGHT | | | IS AVAILABLE OR WHEN THE LIGHTING IS NOT REQUIRED | | | DURING NIGHTTIME HOURS. LIGHTING NOT DESIGNATED FOR | | | DUSK-TO-DAWN OPERATION SHALL BE CONTROLLED BY EITHER A | | | COMBINATION OF A PHOTOSENSOR AND A TIME SWITCH, OR AN | | | ASTRONOMICAL TIME SWITCH. A REFFERENCE IS MADE TO THE | | | USE OF A TIMER AND A PHOTOCELL. PLEASE INDICATE ON THE | | | PALNS THE LOACTION OF THE EQUIPMENT AND IDENTIFY ALL | | | CIRCUIITS THEY OPERATE. | | | | | | 2) 2010 FBC-BUILDING SECTION 1609 | | | PROVIDE WIND LOAD CALCULATIONS FOR ALL LIGHT POLES | | | INCLUDING LUMINAIRE IN COMPLIANCE WITH THE FBC 1609 | | | | | | 3) SHEET E3.1 | | | OUTLETS INDICATED IN THE FIRE RATED TENANT SEPARATION | | | WALL SHALL BE SEPARATED BY A MINIMUM ORF 24" OR | | | PROTECTED BY A FIRE RATED MATERIAL APPROVED FOR THAT | | | USE. FBC 713.3.1.2. | | | | | | 4) ONE 125VOLT, SINGLE-PHASE, 15 OR 20AMP GFI | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE | | | RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND | | | WITHIN 25FT OF THE HEATING, AIR-CONDITIONING, AND | | | REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET SHALL | | | NOT BE CONNECTED TO THE LOAD SIDE OF THE EQUIPMENT | | | DISCONNECTING MEANS. NEC 210.63 SEE 210.8(A)(3), VERIFY | | | THE REQUIRED OUTLETS ARE EXISTING OR INDICATE NEW | | | OUTLETS INCLUDING THE CIRCUIT IN THE CORRESPONDING | | | PANELBOARD. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED | | | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE | | | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE | | | REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-10-22 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-10-22 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-22 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2014-10-22 11:33:47 | 10/22/2014 | | | PROJECT: 3416 S DIXIE HWY | | | PERMIT#: 14100194 | | | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC | | | ,2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET E-1.1 | | | A) SITE LIGHTING. WIND LOADS ON EVERY BUILDING OR | | | STRUCTURE SHALL BE DETERMINED IN ACCORDANCE WITH | | | CHAPTERS 26 THROUGH 30 OF ASCE 7 OR THE PROVISIONS OF | | | THE ALTERNATE ALL HEIGHTS METHOD IN SECTION 1609.6. | | | WIND SHALL BE ASSUMED TO COME FROM ANY HORIZONTAL | | | DIRECTION AND WIND PRESSURES SHALL BE ASSUMED TO ACT | | | NORMAL TO THE SURFACE CONSIDERED. PROVIDE WIND LOAD | | | CALCULATIONS INCLUDING MANUFACTURER SPECIFICATIONS AND | | | SUBMITTALS ON POLES AND LUMINAIRES. | | | B) 505.2.4 EXTERIOR LIGHTING CONTROLS. | | | LIGHTING FOR ALL EXTERIOR APPLICATIONS NOT EXEMPTED IN | | | SECTION 505.1 SHALL HAVE AUTOMATIC CONTROLS CAPABLE OF | | | TURNING OFF EXTERIOR LIGHTING WHEN SUFFICIENT DAYLIGHT | | | IS AVAILABLE OR WHEN THE LIGHTING IS NOT REQUIRED | | | DURING NIGHTTIME HOURS. LIGHTING NOT DESIGNATED FOR | | | DUSK-TO-DAWN OPERATION SHALL BE CONTROLLED BY EITHER A | | | COMBINATION OF A PHOTOSENSOR AND A TIME SWITCH, OR AN | | | ASTRONOMICAL TIME SWITCH. | | | | | | 2) SHEET E3.1 | | | OUTLETS INDICATED IN THE FIRE RATED TENANT SEPARATION | | | WALL SHALL BE SEPARATED BY A MINIMUM ORF 24" OR | | | PROTECTED BY A FIRE RATED MATERIAL APPROVED FOR THAT | | | USE. FBC 713.3.1.2. | | | | | | 3) ONE 125VOLT, SINGLE-PHASE, 15 OR 20AMP GFI | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, | | | AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT. THE | | | RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND | | | WITHIN 25FT OF THE HEATING, AIR-CONDITIONING, AND | | | REFRIGERATION EQUIPMENT. THE RECEPTACLE OUTLET SHALL | | | NOT BE CONNECTED TO THE LOAD SIDE OF THE EQUIPMENT | | | DISCONNECTING MEANS. NEC 210.63 SEE 210.8(A)(3), VERIFY | | | THE REQUIRED OUTLETS ARE EXISTING OR INDICATE NEW | | | OUTLETS INCLUDING THE CIRCUIT IN THE CORRESPONDING | | | PANELBOARD. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2014-12-15 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2014-12-15 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2014-12-15 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2014-12-15 14:23:57 | ALSO APPROVED UNDER APPLICATION E14090021 (ENGINEERING | | | DEVELOPMENT SERVICES) |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2014-11-19 |
|
|
Cont ID |
|
| Sent By |
cranford |
Date |
2014-11-19 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
cranford |
Date |
2014-11-18 |
Time |
15:40 |
Sent To |
I |
|
| Notes |
| 2014-11-18 15:43:40 | ENGINEERING DEPT COMMENTS | | | | | | PAVING, GRADING AND DRAINAGE PLANS WERE NOT INCLUDED. | | | DETAILS OF THE SITE DEVELOPMENT ARE ALSO BEING REVIEWED | | | UNDER ENGINEERING APPLICATION E14090021. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-10-14 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2014-10-14 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2014-10-14 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2014-10-14 15:08:21 | 3416 SOUTH DIXIE HIGHWAY | | | PERMIT #14100194 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | GENERAL: PROVIDE A SITE PLAN. | | | | | | SHEET LS-1.0: REMOVE CODE REFERENCES TO THE 2006 | | | EDITION; UPDATE THE CODE LIST TO REFERENCE THE 2010 | | | EDITION OF THE FLORIDA FIRE PREVENTION CODE WHICH | | | CONTAINS THE 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 | | | WITH FLORIDA AMENDMENTS. | | | | | | SHEET A-1.0: DOOR #101 SERVES MORE THAN 50 PERSONS AND | | | WILL BE REQUIRED TO SWING IN THE DIRECTION OF EGRESS. | | | | | | SHEET A-1.0 TENANT SEPARATION WALL: PER SECTION | | | 8.3.2.4, EACH FIRE BARRIER SHALL BE PERMANENTLY | | | IDENTIFIED WITH SIGNS OR STENCILING READING FIRE | | | BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE AT | | | LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH. | | | IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON | | | CENTER. PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY | | | SHALL BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE. | | | | | | SHEET A-1.0 MAIN ENTRANCE DOOR: KEYED LOCKS OR | | | THUMB-TURN LOCK TO BE EQUIPPED WITH AN ?OPEN/LOCKED? | | | INDICATOR WINDOW (SUCH AS ADAMS RITE 4089 OR SIMILAR). | | | | | | SHEET A-3.0: PER SECTION 10.12.1.2 (NFPA 1), PROVIDE | | | BUILDING ADDRESS VISIBLE FROM THE STREET. NUMBERS SHALL | | | BE ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES | | | IN HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE | | | BACKGROUND. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-01-29 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-01-29 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2015-01-16 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-01-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2015-01-08 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2014-12-05 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-11-19 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2014-11-19 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2014-10-06 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
N |
Date |
2015-02-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-02-05 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-02-05 |
Time |
|
Sent To |
|
|
| Notes |
| 2015-02-05 13:25:09 | IMPACT FEE : MU-2014027791-0000 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-01-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-01-20 11:34:36 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2014-12-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-12-18 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-18 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2014-12-18 13:06:43 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-11-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-11-07 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-11-07 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2014-11-07 09:23:19 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-10-09 |
|
|
Cont ID |
|
| Sent By |
rbergsma |
Date |
2014-10-09 |
Time |
|
Rev Time |
0.50 |
| Received By |
rbergsma |
Date |
2014-10-09 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-12-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-12-17 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-12-17 |
Time |
13:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-10-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-28 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-28 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2014-10-28 14:48:29 | WPB AMEND. TO 2010 FBC SEC.107.2.1. | | | 1) SHOW THE SQUARE FOOTAGE FOR EACH TENANT SPACE ON THE | | | PLAN AND THE OCCUPANT LOAD FOR EACH SPACE. | | | 2) ROOM #102 - THE SINK SHALL COMPLY WITH THE 2010 FL. | | | ACCESSIBILITY CODE SECS. 212, & 606. A 30 INCH BY 48 | | | INCH CLEAR FLOOR SPACE COMPLYING WITH SEC. 305 SHALL BE | | | POSITIONED FOR A FORWARD APPROACH, AND KNEE AND TOE | | | CLEARANCES COMPLYING WITH SEC.306 SHALL BE PROVIDED. | | | 3) SHT. A-3.1 - SHOW THE DIMENSIONS OF THE CLEAR FLOOR | | | SPACE FOR THE FIXTURES ON THE PLAN.COMPLY W/ FL. | | | ACCESSIBILITY CODE SECS.305.3, 604.3.1,. | | | 4) THE TOILET ROOMS SHALL HAVE A TURNING SPACE | | | COMPLYING WITH FL. ACCESS. CODE SECS.304, 304.3.1, | | | 304.3.2. ( EITHER A 60 INCH MINIMUM DIAMETER CIRCULAR | | | SPACE OR A T-SHAPED SPACE WITHIN A 60 INCH SQUARE | | | MINIMUM WITH ARMS AND BASE 36 INCHES WIDE MINIMUM.) | | | 5) SHT. A-2.1 - DETAIL #4 - DETAIL SHOWS THE HEIGHT OF | | | THE SCUPPER AS 5 INCES YET IT ALSO STATES SCUPPER TO BE | | | 4 INCHES IN HEIGHT.CLARIFY. | | | 6) SHT.A-2.1 - DETAIL #7 REFERS TO DETAIL # 5/A-2.0 - | | | THERE IS NO SUCH DETAIL ON A-2.0. CLARIFY. | | | 7) SHT. A-2.0 - ROOF DRAINAGE CALS CALLS OUT PRIMARY & | | | SECONDARY SCUPPERS AS 4" X 8" YET DETAIL #4 ON SHT. | | | A-2.1 SHOWS 4" X 12" SCUPPERS. DETAIL #6 ON SHT. A-2.1. | | | SHOWS THE TYPICAL SCUPPER AS 4" X 12". CLARIFY. | | | 8) DRINKING FOUNTAINS MAY BE REQD. IN THE TENANT SPACES | | | DEPENDING UPON THE OCCUPANT LOAD PER THE FL. PLUMBING | | | CODE TABLE 403.1. | | | 9) SEPARATE SANITARY FACILITIES MAY BE REQD. FOR MALES | | | AND FEMALES PER TABLE 403.1. THIS IS BASE ON SQUARE | | | FOOTAGE OF THE FACILITY. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-01-20 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-01-20 12:02:39 | BUILDING PLAN REVIEW | | | PERMIT: 14100194 | | | ADD: 3416 S. DIXIE HWY | | | CONT: JACOB ERECTING | | | TEL: (561)741-1818 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: MON. JAN 20/2015 | | | ACTION: BUILDING PROVISO | | | | | | 1) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.41 COMPONENTS & CLADDING.FLORIDA DEPARTMENT OF | | | COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) | | | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT | | | WILL REQUIRE PRODUCT APPROVALS: | | | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES NO SUB-SYSTEM | | | HAS BEEN IDENTIFIED, ENHANCED FASTENING WILL BE | | | REQUIRED FOR THE ROOF INSULATION AS WELL AS THE ROOFING | | | SYSTEM, SEE IF LIMITATION #7 OR #9. | | | | | | ONCE THE CONTRACTOR PICKS WHICH ROOFING SUB-SYSTEM IS | | | TO BE APPLIED TO THE ROOF DECK, THE PRODUCT APPROVAL | | | MUST BE REVIEWED BY THE DESIGNER OF RECORD AND SHOP | | | DRAWING STAMP OF APPROVAL APPLIED. RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2015-02-09 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2015-02-09 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2015-02-05 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2015-02-05 13:45:44 | IMPORTANT NOTICE: EFFECTIVE MARCH 2, 2015 | | | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED | | | ELECTRONICALLY | | | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS | | | SUBMISSION OPTIONS ARE AS FOLLOWS: | | | 1 UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT | | | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL | | | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED | | | NAMING CONVENTION FOR EACH DOCUMENT | | | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER | | | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE | | | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT | | | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT | | | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS | | | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES | | | AVAILABLE | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2015-01-23 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2015-01-23 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2015-01-23 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2015-01-23 14:44:48 | ZONING APPROVED FOR NEW RETAIL BUILDING ONLY. SEPARATE | | | PERMITS REQUIRED FOR: LANDSCAPING, SIGNAGE AND PAVEMENT | | | STRIPING. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2014-12-15 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2014-12-15 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-12-15 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2014-12-15 15:14:36 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) REPEAT COMMENT FROM 11/17/14: PERMIT PLANS | | | INCOMPLETE. SET MISSING THE SITE PLAN WITH SITE DATA | | | INFORMATION, PARKING CALCULATIONS, SITE DETAILS, ETC. | | | PER THE APPROVED SITE PLAN. (REFERENCE ISPR 14-05) | | | | | | PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | | MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE | | | @ (561) 822-1458 IF YOU HAVE QUESTIONS. | | | | | | | | | OTHER NOTES: | | | | | | 1.) SEPARATE REVIEW AND PERMIT APPLICATIONS REQUIRED | | | FOR: SIGNAGE, LANDSCAPING AND AWNINGS. | | | | | | 2.) ALL OUTDOOR LIGHTING SHALL BE SHIELDED TO REDUCE | | | GLARE AND SHALL BE ARRANGED TO REFLECT LIGHT OR GLARE | | | AWAY FROM ALL ADJACENT RESIDENTIAL DISTRICTS, ADJACENT | | | RESIDENCES OR PUBLIC THOROUGHFARES. [ZLDR S.94-309(A)] | | | | | | PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | | MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE | | | @ (561) 822-1458 IF YOU HAVE QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2014-11-17 |
|
|
Cont ID |
|
| Sent By |
llioue |
Date |
2014-11-17 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-11-17 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2014-11-17 15:52:41 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) PERMIT PLANS INCOMPLETE. SET MISSING THE SITE PLAN | | | WITH SITE DATA INFORMATION, PARKING CALCULATIONS, SITE | | | DETAILS, ETC. PER THE APPROVED SITE PLAN. (REFERENCE | | | ISPR 14-05) | | | | | | 2.) PROVIDE DETAILS AND ILLUSTRATIONS SHOWING WHAT THE | | | LIGHT FIXTURES WILL LOOK LIKE. | | | | | | 3.) THE PROPERTY ABUTS A HISTORIC RESIDENTIAL DISTRICT. | | | PLEASE ADDRESS HOW THE PROPOSED LIGHTING WILL COMPLY | | | WITH THE FOLLOWING LIGHTING STANDARDS: | | | | | | - ALL OUTDOOR LIGHTING SHALL BE SHIELDED TO REDUCE | | | GLARE AND SHALL BE ARRANGED TO REFLECT LIGHT OR GLARE | | | AWAY FROM ALL ADJACENT RESIDENTIAL DISTRICTS, ADJACENT | | | RESIDENCES OR PUBLIC THOROUGHFARES. [ZLDR S.94-309(A)] | | | | | | - ANY OPERATION OR ACTIVITY PRODUCING GLARE SHALL BE | | | CONDUCTED SO THAT DIRECT OR INDIRECT LIGHT FROM THE | | | SOURCE SHALL NOT CAUSE ILLUMINATION IN EXCESS OF 0.5 | | | FOOT CANDLES WHEN MEASURED IN A RESIDENTIAL DISTRICT. | | | [ZLDR S.94-310(D)] | | | | | | 4.) SEPARATE REVIEW AND PERMIT APPLICATIONS REQUIRED | | | FOR: SIGNAGE, LANDSCAPING, AWNINGS, PARKING LOT | | | STRIPING. | | | | | | PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | | MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE | | | @ (561) 822-1458 IF YOU HAVE QUESTIONS. | | | | | 2014-10-09 14:50:10 | 10/9/14 |
|
|
|