Plan Review Details - Permit 14100055
| Plan Review Stops For Permit 14100055 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-10-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-10-31 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-31 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2014-10-31 08:27:05 | ****PROVISO**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. PROVIDE A LETTER OR A REVISED PLAN FROM DESIGN | | | PROFESSIONAL (ARCHITECT OR ENGINEER) WHICH INCORPORATES | | | MINIMUM ELEVATION OF 7'6" FOR THE NEW BAR. | | | | | | 2. ELEVATION CERTIFICATE WHICH SHOWS THE NEW BAR AT | | | 7'6" TO BE PROVIDED PRIOR TO FINAL INSPECTION. | | | | | | 3. ALL NEW MATERIALS BELOW 7'6" ARE TO COMPLY WITH FBC | | | 1612, FLOOD LOADS. ARCHITECT'S PLAN PROPOSES THAT | | | IMPROVEMENTS WILL RESIST FLOOD LOADS AND FLOTATION, BUT | | | THE PLAN DOES NOT ADDRESS FLOOD RESISTANT MATERIALS. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
shill |
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-02 |
Time |
15:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-10-16 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-10-16 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-10-16 |
Time |
13:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-10-20 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-10-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-10-20 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-10-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-10-31 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-09 |
Time |
06:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2014-10-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-10-30 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-10-30 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2014-10-30 13:10:29 | NO MECHANICAL WORK AT THIS TIME. HM. |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2014-10-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-10-02 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-02 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2014-10-02 15:18:49 | NOT A SUBSTANTIAL IMPROVEMENT | | | THEREFORE ONLY THE NEW PORTION (NEW BAR TO REPLACE | | | EXISTING BAR) TO COMPLY WITH ELEVATION REQUIREMENT OF | | | 7'6" | | | FBC 2010 EXISTING BUILDING 101.5(EXCEPTION); OK PER DH | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-10-29 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-29 |
Time |
05:53 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-29 |
Time |
05:53 |
Sent To |
|
|
| Notes |
|
|
|