Plan Review Details - Permit 14091032
| Plan Review Stops For Permit 14091032 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2014-10-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-01 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-01 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2014-09-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-30 |
Time |
04:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-30 |
Time |
04:33 |
Sent To |
|
|
| Notes |
| 2014-09-30 04:47:56 | WPB AMEND. TO 2010 FBC SEC. 107.2.1, 2010 FUEL GAS CODE | | | TABLES 402.4 (2), TABLE 402.4 (20), SEC.402.4.3. | | | | | | 1) THE COPIES OF THE GAS SIZING TABLES FOR THE P.E. | | | PIPE AND THE METALLIC PIPE ARE FROM THE 2004 FLORIDA | | | FUEL GAS CODE WHICH IS 3 CODE CYCLES AGO. THE GAS CODE | | | IN EFFECT AT THIS TIME IS THE 2010 FLORIDA FUEL GAS | | | CODE.SUBMIT COPIES OF THE APPLICABLE SIZING TABLES FROM | | | THE CURRENT CODE EDITION | | | 2) YOU IDENTIFIED THE MAXIMUM CAPACITY OF THE 3/4" SCH. | | | 40 GALVINIZED PIPE AS 250,000 BTU'S ON THE PLAN BUT THE | | | TWO APPLIANCES ON THIS LINE ADD UP TO 364,000 BTU'S SO | | | THE 3/4" SIZE WILL NOT MEET THE DEMAND. THE LINE NEEDS | | | TO BE 1". | | | 3) SHOW THE LOCATION OF THE SECOND STAGE REGULATOR ON | | | THE RISER DIAGRAM. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-10-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-01 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-01 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-30 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-30 |
Time |
04:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-29 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2014-09-29 12:39:28 | ROUTED TO PLUMBING $5000 & UNDER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2014-10-01 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-01 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-10-01 09:29:51 | PLUMBING REVIEW STOP ENTERED ERRONEOUSLY. T.LARGE. |
|
|
|