| Plan Review Stops For Permit 14090908 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2015-03-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2015-03-16 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-03-16 |
Time |
07:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2015-02-06 |
|
|
Cont ID |
|
| Sent By |
JWITMER |
Date |
2015-02-06 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-02-06 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2015-02-06 15:13:28 | BUILDING PLAN REVIEW | | | PERMIT: 14090908 | | | ADD: 901 VILLAGE BLVD SUITE 702 | | | CONT: PM BUILDERS | | | TEL: (561)330-3833 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: FRI. FEB. 06/2015 | | | | | | ACTION: BUILDING PROVISO | | | | | | 1) DEFERRED SUBMITTALS 2010 WEST PALM BEACH AMENDMENTS | | | TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION, 107.3.4.2 DEFERRED SUBMITTALS. FOR THE | | | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE | | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | | REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED | | | SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL | | | REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL | | | WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL | | | DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL | | | CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED | | | SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE | | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE | | | BUILDING OFFICIAL. | | | | | | SHEET S-1 INDICATES THE USE OF NEW STOREFRONT WINDOWS | | | AND DOORS. PLEASE PROVIDE COMPLIANCE WITH: | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS/ MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-12-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-12-15 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-12-15 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2014-12-15 16:51:12 | BUILDING PLAN REVIEW | | | PERMIT: 14090908 | | | ADD: 901 VILLAGE BLVD SUITE 702 | | | CONT: PM BUILDERS | | | TEL: (561)330-3833 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. DEC. 15/2014 | | | ACTION: DENIED | | | | | | 1)COMPLIED. | | | | | | 2A) COMPLIED. | | | PLEASE PROVIDE A LIFE SAFETY PLAN FOR THE PHASED SCOPE | | | OF WORK WITH EXIT SIGNS AND DIRECTIONAL SIGNAGE. 2010 | | | FBC-B 1006.3.1 & 1006.3.8. | | | | | | 2B) NEW DESIGN AND THE TOTAL OCCUPANT LOAD FOR THE | | | SPACE BEING 72 REQUIRES ALL DOORS TO SWING IN THE | | | EGRESS PATH OF TRAVEL. 2010 FBC-B 1008.1.2. | | | SEE THE DOOR BETWEEN THE WAITING ROOM 163 & HALL/ CHECK | | | OUT ROOM # 173. | | | | | | 3) SHEET S-1 INDICATES THE USE OF NEW STOREFRONT | | | WINDOWS AND DOORS. PLEASE PROVIDE COMPLIANCE WITH: | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, | | | | | | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 5-7) COMPLIED. | | | | | | 8) NEW COMMENT. SHEET A-2 BATHROOM ROOM # 186 INDICATES | | | THE USE OF A 18 INCH WIDE ADA BENCH. PLEASE REVIEW 2010 | | | FBC- ACCESS. CODE 903.3 THE MINIMUM DEPTH OF THE BENCH | | | IS 20 INCHES. ACCESS. CODE 903.4 WILL EITHER REQUIRE A | | | BACK SUPPORT OR SECURED TO THE WALL. | | | | | | 9) BATHROOM # 186 PLEASE PROVIDE CODE COMPLIANCE FOR | | | THE ADA SHOWER; | | | 9A) PLEASE PROVIDE THE SIZE OF THE SHOWER 608.2. | | | | | | 9B) PLEASE SHOW COMPLIANCE WITH 608.2.1 TRANSFER TYPE | | | SHOWERS. | | | | | | 9C) 608.3 GRAB BAR LOCATION & HEIGTH. | | | | | | 9D) 608.3.1 TRANSFER TYPE SHOWER COMPARTMENTS. | | | | | | 9E) 608.4 SEATS. | | | | | | 9F) 608.5. CONTROLS | | | | | | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | 608.2.1 | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-10-01 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-10-01 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2014-10-01 14:25:05 | BUILDING PLAN REVIEW | | | PERMIT: 14090908 | | | ADD: 901 VILLAGE BLVD SUITE 702 | | | CONT: PM BUILDERS | | | TEL: (561)330-3833 | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. OCT. 01 /2014 | | | ACTION: DENIED | | | | | | 1) PLEASE PROVIDE THE MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS: | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 107.3.5 MINIMUM PLAN | | | REVIEW CRITERIA FOR BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | | SHALL BE DETERMINED. | | | MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE | | | TABLE 503). | | | FIRE SPRINKLERED OR NOT THIS WILL AFFECT TRAVEL LENGTHS | | | AND DEAD ENDS. | | | | | | 2A) PLEASE PROVIDE A LIFE SAFETY PLAN FOR THE PHASED | | | SCOPE OF WORK WITH EXIT SIGNS AND DIRECTIONAL SIGNAGE. | | | 2010 FBC-B 1006.3.1 & 1006.3.8. | | | | | | 2B) THE ELECTRICAL SHEETS SHOW A EXIT SIGN THROUGH THE | | | NEURO FEEDBACK ROOM, 2010 FBC-B 1014.2 EGRESS THROUGH | | | INTERVENING SPACES 4. EGRESS SHALL NOT PASS THROUGH | | | KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED FOR | | | SIMILAR PURPOSES. ROOMS THAT CAN BE LOCKABLE. | | | | | | 3) SHEET S-1 INDICATES THE USE OF NEW STOREFRONT | | | WINDOWS AND DOORS. PLEASE PROVIDE COMPLIANCE WITH: | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41 | | | COMPONENTS & CLADDING | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, | | | | | | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 5) INTERIOR DECORATOR PLANS DESIGNED BY P2 INTERIORS, | | | LICENSE # IB26001537 ARE NOT SIGNED NOR SEALED. | | | 61G1-16.003 USE OF SEAL. EFFECTIVE 04/18/2000 THE | | | PERSONAL SEAL, SIGNATURE AND DATE OF THE ARCHITECT OR | | | INTERIOR DESIGNER SHALL APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DOCUMENTS TO BE FILED FOR PUBLIC | | | RECORD. | | | | | | 6) IMPACT FEES- NOT REQUIRED. | | | | | | 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2015-03-23 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-03-23 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-03-23 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-12-04 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-12-04 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-12-04 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-10-02 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-10-02 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-10-02 |
Time |
13:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2015-03-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-03-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-03-12 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-12-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-12-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-12-05 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-10-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-10-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-10-06 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2014-10-06 11:46:00 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | SHEET LS-1- PLEASE ADD EXIT SIGNS AND EMERGENCY LIGHTS | | | WHERE INDICATED AND HAND DRAWN. | | | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE | | | FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND | | | COMPLIANCE. | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-03-23 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2015-03-23 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2015-03-04 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-02-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2015-02-26 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-01-22 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-12-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-12-16 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-12-04 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-10-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-20 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-25 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-10-01 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-10-01 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2014-10-01 14:25:53 | IMPAT FEE ASSESSMENT NOT REQUIRED, I CALLED MICHELLE | | | 233-5019 IF PART OF A SHOPPING MALL NOT REQUIRED. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2015-02-26 |
|
|
Cont ID |
|
| Sent By |
HMOSER |
Date |
2015-02-26 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2015-02-26 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2014-12-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-12-16 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-12-16 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2014-12-16 17:31:37 | PLAN DENIED | | | | | | 1) SUBMIT A COMPLETE SET OF PLANS SHOWING | | | ALL FOUR AIR CONDITIONING UNITS AND DUCT WORK. | | | PER SECTION 107 FBC 2010 | | | 2) PROVIDE A DETAIL FROM THE ENGINEER ON EQUIPMENT TIE | | | DOWN | | | TO ROOF AND EQUIPMENT TIE DOWN TO STAND OR CURB | | | PER SECTION 301.12 WIND RESISTANCE FBC (M) 2010 | | | 3) SUBMIT ENERGY CALCULATIONS WITH THE PLANS | | | PER SECTION 503.2.1 FLORIDA ENERGY CODE 2010 | | | 4) REFER TO SECTION 503.2.5.4 SHUT OFF DAMPER | | | CONTROLS FLORIDA ENERGY CODE 2010 | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-10-08 |
|
|
Cont ID |
|
| Sent By |
rbergsma |
Date |
2014-10-08 |
Time |
|
Rev Time |
1.00 |
| Received By |
rbergsma |
Date |
2014-10-08 |
Time |
|
Sent To |
|
|
| Notes |
| 2014-10-08 13:26:14 | SHOW SIZE AND ROUTE OF EXHAUST DUCT TO OUTSIDE BLDG | | | SHOW DUCT SIZES, CFM, MATERIAL AND INSULATION R-VALUE | | | SHOW DISTANCE BETWEEN AIR INTAKES TO EXH. OR VENTS (10 | | | FT MIN ) | | | INDICATE WHICH EQUIPMENT IS NEW OR USED | | | THERE ARE 2 RTU UNITS LABELED #1 ON THE SCHEDULE | | | IF ANY OF THE A/C EQUIPMENT IS NEW , SUBMIT LOAD CALC'S | | | FOR THAT AREA |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2015-03-23 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2015-03-23 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-03-23 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2015-01-28 |
|
|
Cont ID |
|
| Sent By |
TKLARGE |
Date |
2015-01-28 |
Time |
05:33 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-01-27 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2015-01-28 05:32:58 | 1) CLEARLY SHOW THE INTERIOR DIMENSIONS OF THE ADA | | | SHOWER (L X W). THE DIMENSIONS ON SHT. A-1 ARE | | | ILLEGIBLE. THE PLANS SHALL BE DRAWN TO A MIN. 1/8 INCH | | | SCALE. SHT. A-1 IS CLEARLY NOT DRAWN TO AN 1/8 INCH | | | SCALE. WPB AMEND. TO 2010 FBC SEC.107.2.1, 107.2.1.4. | | | 2) THE ADA SHOWER DIMENSIONS APPEAR TO BE 38" X 39". | | | ACCESSIBLE TRANSFER SHOWERS SHALL BE 36" X 36" PER THE | | | FAC SEC.608.2. SEE SHEETS A-1 & A-6. | | | 3) SHT. A-6 - THE SEAT IN THE ACCESSIBLE SHOWER SHALL | | | COMPLY WITH THE FAC SEC.610.3.2. SHOW THIS ON THE | | | PLANS. SEE FIGURES 610.3.2 & 610.4 OF THE 2010 FAC. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-12-13 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-12-13 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-12-13 |
Time |
05:14 |
Sent To |
|
|
| Notes |
| 2014-12-13 07:49:04 | 1 )SHT A-5 SHOWS ROOM 219 AS A HATCHED AREA FOR NO WORK | | | BEING DONE BUT SHTS.A-1 & D-2 SHOW THIS AS AN AREA | | | WHERE WORK IS BEING DONE. CLARIFY. | | | 2) SHOW THE LENGTH AND WIDTH DIMENSIONS OF THE ADA | | | SHOWER. COMPLY W/SEC.608.2.1 OF THE 2010FL. ACCESS. | | | CODE. | | | 3) PROVIDE AN ELEVATION DETAIL OF THE ADA SHOWER. THE | | | SHOWER SHALL HAVE A SEAT THAT COMPLIES W/ FAC | | | SEC.608.4. | | | 4) THE ADA SHOWER SHALL COMPLY W/FAC SEC. 608.2.1.FOR | | | ENTRY SIZE AND THE REQUIRED CLEAR FLOOR OUTSIDE OF THE | | | ENTRY WAY. | | | 5) GRAB BARS IN THE ADA SHOWER SHALL COMPLY W/ FAC | | | SEC.608.3.1. | | | 6) THE SHOWER CONTROLS SHALL COMPLY WITH 2010 FAC | | | SEC.608.5.1 | | | THE SINK IN BREAKROOM #218 IS NOT SHOWN ON THE SANITARY | | | OR WATER RISER DIAGRAMS. 2ND REQUEST. | | | 7) SIZE ALL SECTIONS OF THE VENTING SYSTEM ON SANITARY | | | RISER "B". | | | 8) SHT. P-2- REMOVE THE REFERENCE TO THE 2007 FBCAND | | | INSERT 2010 FBC. | | | 9) AS DESIGNED, THE WATER CLOSET IN ROOM 186 ON | | | SANITARY RISER "A" IS CREATING A HORIZONTAL WET VENT | | | AND DOES NOT COMPLY WITH 2010 FPC SEC.909.1 AS TO THE | | | TYPE AND NUMBER OF PLUMBING FIXTURES PERMITTED. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-10-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-20 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-20 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2014-10-20 10:37:41 | 1) 5 % BUT NO LESS THAN ONE OF THE SINKS IN THE EXAM | | | ROOMS AND OTHER ROOMS SHALL COMPLY WITH THE 2010 | | | FLORIDA ACCESSIBILITY CODE SECS. 212.3, 306, & 606. | | | 2) SHT. P-2 - SIZE ALL SECTIONS OF THE SANITARY AND | | | WATER RISER DIAGRAMS. WPB AMEND. TO 2010 FBC SEC. | | | 107.2.1. | | | 3) SHT. P-2 - DRAINS FOR SINKS IN ROOMS 187 & 188 ARE | | | DRAWN IN THE OPPOSITE DIRECTION OF FLOW AT THE | | | CONNECTION TO THE EXISTING LINE. | | | 4) SHT. P-2 - THE HUB DRAIN IN ROOM #205 REQUIRES A | | | TRAP SEAL PER THE 2010 FPC SECS. 1002.1, 1002.4. | | | 5) SHT. P-2 - THE BREAK ROOM SINK IS NOT SHOWN ON THE | | | SANITARY RISER. WPB AMEND. TO 2010FBC SEC.107.2.1. | | | 6) THE SINK IN RM. #188 IS NOTED AS EXISTING ON THE | | | SANITARY RISER BUT AS NEW ON THE WATER RISER. CLARIFY. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-03-12 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-03-12 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-03-10 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2015-03-12 11:31:12 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 3/12/15 | | | | | | 1. WILL THERE BE ANY INCREASE IN BUILDING FOOTPRINT | | | SQUARE FOOTAGE WITH THE PROPOSED FA?ADE IMPROVEMENT? | | | PLEASE PROVIDE AN OVERLAY OF THE OLD AND NEW TO CONFIRM | | | THE CHANGES. | | | | | | 2. ADDITIONALLY, UNTIL THE FA?ADE IMPROVEMENT LOCATION | | | IS CONFIRMED, IT IS UNCLEAR IF THERE IS ANY IMPACT TO | | | THE PEDESTRIAN WALKWAY. IF THE FA?ADE LOCATION IS | | | CHANGING RESULTING IN ANY DECREASE IN THE WIDTH OF THE | | | COVERED WALKWAY AN ADDITIONAL REVIEW WILL BE REQUIRED | | | TO ASSESS WALKWAY WIDTHS AND CONFLICTS WITH COLUMNS. AN | | | INCREASE IN BUILDING FOOTPRINT MAY ALSO TRIGGER A MINOR | | | PLANNED DEVELOPMENT AMENDMENT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | | | | | | | |
|
|