Plan Review Details - Permit 14090908
Plan Review Stops For Permit 14090908
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2015-03-16 Cont ID  
Sent By jwitmer Date 2015-03-16 Time 07:33 Rev Time 0.00
Received By jwitmer Date 2015-03-16 Time 07:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2015-02-06 Cont ID  
Sent By JWITMER Date 2015-02-06 Time 15:13 Rev Time 0.00
Received By jwitmer Date 2015-02-06 Time 11:03 Sent To  
Notes
2015-02-06 15:13:28BUILDING PLAN REVIEW
 PERMIT: 14090908
 ADD: 901 VILLAGE BLVD SUITE 702
 CONT: PM BUILDERS
 TEL: (561)330-3833
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: FRI. FEB. 06/2015
  
 ACTION: BUILDING PROVISO
  
 1) DEFERRED SUBMITTALS 2010 WEST PALM BEACH AMENDMENTS
 TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION, 107.3.4.2 DEFERRED SUBMITTALS. FOR THE
 PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE
 APPLICATION AND THAT ARE TO BE SUBMITTED TO THE
 BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL
 OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF
 THE BUILDING OFFICIAL. THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE
 DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR
 REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED
 SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL
 REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL
 WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL
 DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL
 CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED
 SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE
 DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE
 BUILDING OFFICIAL.
  
 SHEET S-1 INDICATES THE USE OF NEW STOREFRONT WINDOWS
 AND DOORS. PLEASE PROVIDE COMPLIANCE WITH:
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS/ MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS,
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-12-15 Cont ID  
Sent By jwitmer Date 2014-12-15 Time 16:51 Rev Time 0.00
Received By jwitmer Date 2014-12-15 Time 14:47 Sent To  
Notes
2014-12-15 16:51:12BUILDING PLAN REVIEW
 PERMIT: 14090908
 ADD: 901 VILLAGE BLVD SUITE 702
 CONT: PM BUILDERS
 TEL: (561)330-3833
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. DEC. 15/2014
 ACTION: DENIED
  
 1)COMPLIED.
  
 2A) COMPLIED.
 PLEASE PROVIDE A LIFE SAFETY PLAN FOR THE PHASED SCOPE
 OF WORK WITH EXIT SIGNS AND DIRECTIONAL SIGNAGE. 2010
 FBC-B 1006.3.1 & 1006.3.8.
  
 2B) NEW DESIGN AND THE TOTAL OCCUPANT LOAD FOR THE
 SPACE BEING 72 REQUIRES ALL DOORS TO SWING IN THE
 EGRESS PATH OF TRAVEL. 2010 FBC-B 1008.1.2.
 SEE THE DOOR BETWEEN THE WAITING ROOM 163 & HALL/ CHECK
 OUT ROOM # 173.
  
 3) SHEET S-1 INDICATES THE USE OF NEW STOREFRONT
 WINDOWS AND DOORS. PLEASE PROVIDE COMPLIANCE WITH:
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS,
  
 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 5-7) COMPLIED.
  
 8) NEW COMMENT. SHEET A-2 BATHROOM ROOM # 186 INDICATES
 THE USE OF A 18 INCH WIDE ADA BENCH. PLEASE REVIEW 2010
 FBC- ACCESS. CODE 903.3 THE MINIMUM DEPTH OF THE BENCH
 IS 20 INCHES. ACCESS. CODE 903.4 WILL EITHER REQUIRE A
 BACK SUPPORT OR SECURED TO THE WALL.
  
 9) BATHROOM # 186 PLEASE PROVIDE CODE COMPLIANCE FOR
 THE ADA SHOWER;
 9A) PLEASE PROVIDE THE SIZE OF THE SHOWER 608.2.
  
 9B) PLEASE SHOW COMPLIANCE WITH 608.2.1 TRANSFER TYPE
 SHOWERS.
  
 9C) 608.3 GRAB BAR LOCATION & HEIGTH.
  
 9D) 608.3.1 TRANSFER TYPE SHOWER COMPARTMENTS.
  
 9E) 608.4 SEATS.
  
 9F) 608.5. CONTROLS
  
 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
 608.2.1
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-10-01 Cont ID  
Sent By jwitmer Date 2014-10-01 Time 14:25 Rev Time 0.00
Received By jwitmer Date 2014-10-01 Time 08:55 Sent To  
Notes
2014-10-01 14:25:05BUILDING PLAN REVIEW
 PERMIT: 14090908
 ADD: 901 VILLAGE BLVD SUITE 702
 CONT: PM BUILDERS
 TEL: (561)330-3833
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. OCT. 01 /2014
 ACTION: DENIED
  
 1) PLEASE PROVIDE THE MINIMUM PLAN REVIEW CRITERIA FOR
 BUILDINGS:
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 107.3.5 MINIMUM PLAN
 REVIEW CRITERIA FOR BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.1 BUILDING
 OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS
 SHALL BE DETERMINED.
 MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED (SEE
 TABLE 503).
 FIRE SPRINKLERED OR NOT THIS WILL AFFECT TRAVEL LENGTHS
 AND DEAD ENDS.
  
 2A) PLEASE PROVIDE A LIFE SAFETY PLAN FOR THE PHASED
 SCOPE OF WORK WITH EXIT SIGNS AND DIRECTIONAL SIGNAGE.
 2010 FBC-B 1006.3.1 & 1006.3.8.
  
 2B) THE ELECTRICAL SHEETS SHOW A EXIT SIGN THROUGH THE
 NEURO FEEDBACK ROOM, 2010 FBC-B 1014.2 EGRESS THROUGH
 INTERVENING SPACES 4. EGRESS SHALL NOT PASS THROUGH
 KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED FOR
 SIMILAR PURPOSES. ROOMS THAT CAN BE LOCKABLE.
  
 3) SHEET S-1 INDICATES THE USE OF NEW STOREFRONT
 WINDOWS AND DOORS. PLEASE PROVIDE COMPLIANCE WITH:
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.41
 COMPONENTS & CLADDING
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS,
  
 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 5) INTERIOR DECORATOR PLANS DESIGNED BY P2 INTERIORS,
 LICENSE # IB26001537 ARE NOT SIGNED NOR SEALED.
 61G1-16.003 USE OF SEAL. EFFECTIVE 04/18/2000 THE
 PERSONAL SEAL, SIGNATURE AND DATE OF THE ARCHITECT OR
 INTERIOR DESIGNER SHALL APPEAR ON ALL ARCHITECTURAL OR
 INTERIOR DESIGN DOCUMENTS TO BE FILED FOR PUBLIC
 RECORD.
  
 6) IMPACT FEES- NOT REQUIRED.
  
 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2015-03-23 Cont ID  
Sent By dhayes Date 2015-03-23 Time 14:28 Rev Time 0.00
Received By dhayes Date 2015-03-23 Time 13:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-12-04 Cont ID  
Sent By dhayes Date 2014-12-04 Time 16:31 Rev Time 0.00
Received By dhayes Date 2014-12-04 Time 15:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-10-02 Cont ID  
Sent By rlecky Date 2014-10-02 Time 13:51 Rev Time 0.00
Received By rlecky Date 2014-10-02 Time 13:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2015-03-13 Cont ID  
Sent By pleduc Date 2015-03-12 Time   Rev Time 0.00
Received By pleduc Date 2015-03-12 Time 15:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2014-12-05 Cont ID  
Sent By pleduc Date 2014-12-05 Time   Rev Time 0.00
Received By pleduc Date 2014-12-05 Time 11:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2014-10-06 Cont ID  
Sent By pleduc Date 2014-10-06 Time   Rev Time 0.00
Received By pleduc Date 2014-10-06 Time 11:20 Sent To  
Notes
2014-10-06 11:46:00THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 SHEET LS-1- PLEASE ADD EXIT SIGNS AND EMERGENCY LIGHTS
 WHERE INDICATED AND HAND DRAWN.
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE
 FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND
 COMPLIANCE.
  
 THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER
 SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND
 BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2015-03-23 Cont ID  
Sent By dhayes Date 2015-03-23 Time 14:50 Rev Time 0.00
Received By dhayes Date 2015-03-04 Time 08:43 Sent To  
Notes
2015-03-05 08:43:41C15

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2015-02-26 Cont ID  
Sent By hmoser Date 2015-02-26 Time 16:46 Rev Time 0.00
Received By hmoser Date 2015-01-22 Time 14:45 Sent To  
Notes
2015-01-23 14:47:59C17

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-12-16 Cont ID  
Sent By hmoser Date 2014-12-16 Time 17:31 Rev Time 0.00
Received By hmoser Date 2014-12-04 Time 14:50 Sent To  
Notes
2014-12-04 15:19:45C16

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-10-20 Cont ID  
Sent By tklarge Date 2014-10-20 Time 10:37 Rev Time 0.00
Received By tklarge Date 2014-09-25 Time 16:06 Sent To  
Notes
2014-09-26 16:07:03B20

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2014-10-01 Cont ID  
Sent By jwitmer Date 2014-10-01 Time 14:26 Rev Time 0.00
Received By jwitmer Date 2014-10-01 Time 14:25 Sent To  
Notes
2014-10-01 14:25:53IMPAT FEE ASSESSMENT NOT REQUIRED, I CALLED MICHELLE
 233-5019 IF PART OF A SHOPPING MALL NOT REQUIRED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2015-02-26 Cont ID  
Sent By HMOSER Date 2015-02-26 Time 16:46 Rev Time 0.00
Received By hmoser Date 2015-02-26 Time 16:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2014-12-16 Cont ID  
Sent By hmoser Date 2014-12-16 Time 17:31 Rev Time 0.00
Received By hmoser Date 2014-12-16 Time 16:47 Sent To  
Notes
2014-12-16 17:31:37PLAN DENIED
  
 1) SUBMIT A COMPLETE SET OF PLANS SHOWING
 ALL FOUR AIR CONDITIONING UNITS AND DUCT WORK.
 PER SECTION 107 FBC 2010
 2) PROVIDE A DETAIL FROM THE ENGINEER ON EQUIPMENT TIE
 DOWN
 TO ROOF AND EQUIPMENT TIE DOWN TO STAND OR CURB
 PER SECTION 301.12 WIND RESISTANCE FBC (M) 2010
 3) SUBMIT ENERGY CALCULATIONS WITH THE PLANS
 PER SECTION 503.2.1 FLORIDA ENERGY CODE 2010
 4) REFER TO SECTION 503.2.5.4 SHUT OFF DAMPER
 CONTROLS FLORIDA ENERGY CODE 2010
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-10-08 Cont ID  
Sent By rbergsma Date 2014-10-08 Time   Rev Time 1.00
Received By rbergsma Date 2014-10-08 Time   Sent To  
Notes
2014-10-08 13:26:14SHOW SIZE AND ROUTE OF EXHAUST DUCT TO OUTSIDE BLDG
 SHOW DUCT SIZES, CFM, MATERIAL AND INSULATION R-VALUE
 SHOW DISTANCE BETWEEN AIR INTAKES TO EXH. OR VENTS (10
 FT MIN )
 INDICATE WHICH EQUIPMENT IS NEW OR USED
 THERE ARE 2 RTU UNITS LABELED #1 ON THE SCHEDULE
 IF ANY OF THE A/C EQUIPMENT IS NEW , SUBMIT LOAD CALC'S
 FOR THAT AREA

Review Stop P PLUMBING
Rev No 4 Status P Date 2015-03-23 Cont ID  
Sent By tlarge Date 2015-03-23 Time 12:17 Rev Time 0.00
Received By tklarge Date 2015-03-23 Time 11:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2015-01-28 Cont ID  
Sent By TKLARGE Date 2015-01-28 Time 05:33 Rev Time 0.00
Received By tklarge Date 2015-01-27 Time 06:32 Sent To  
Notes
2015-01-28 05:32:581) CLEARLY SHOW THE INTERIOR DIMENSIONS OF THE ADA
 SHOWER (L X W). THE DIMENSIONS ON SHT. A-1 ARE
 ILLEGIBLE. THE PLANS SHALL BE DRAWN TO A MIN. 1/8 INCH
 SCALE. SHT. A-1 IS CLEARLY NOT DRAWN TO AN 1/8 INCH
 SCALE. WPB AMEND. TO 2010 FBC SEC.107.2.1, 107.2.1.4.
 2) THE ADA SHOWER DIMENSIONS APPEAR TO BE 38" X 39".
 ACCESSIBLE TRANSFER SHOWERS SHALL BE 36" X 36" PER THE
 FAC SEC.608.2. SEE SHEETS A-1 & A-6.
 3) SHT. A-6 - THE SEAT IN THE ACCESSIBLE SHOWER SHALL
 COMPLY WITH THE FAC SEC.610.3.2. SHOW THIS ON THE
 PLANS. SEE FIGURES 610.3.2 & 610.4 OF THE 2010 FAC.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2014-12-13 Cont ID  
Sent By tklarge Date 2014-12-13 Time 07:49 Rev Time 0.00
Received By tklarge Date 2014-12-13 Time 05:14 Sent To  
Notes
2014-12-13 07:49:041 )SHT A-5 SHOWS ROOM 219 AS A HATCHED AREA FOR NO WORK
 BEING DONE BUT SHTS.A-1 & D-2 SHOW THIS AS AN AREA
 WHERE WORK IS BEING DONE. CLARIFY.
 2) SHOW THE LENGTH AND WIDTH DIMENSIONS OF THE ADA
 SHOWER. COMPLY W/SEC.608.2.1 OF THE 2010FL. ACCESS.
 CODE.
 3) PROVIDE AN ELEVATION DETAIL OF THE ADA SHOWER. THE
 SHOWER SHALL HAVE A SEAT THAT COMPLIES W/ FAC
 SEC.608.4.
 4) THE ADA SHOWER SHALL COMPLY W/FAC SEC. 608.2.1.FOR
 ENTRY SIZE AND THE REQUIRED CLEAR FLOOR OUTSIDE OF THE
 ENTRY WAY.
 5) GRAB BARS IN THE ADA SHOWER SHALL COMPLY W/ FAC
 SEC.608.3.1.
 6) THE SHOWER CONTROLS SHALL COMPLY WITH 2010 FAC
 SEC.608.5.1
 THE SINK IN BREAKROOM #218 IS NOT SHOWN ON THE SANITARY
 OR WATER RISER DIAGRAMS. 2ND REQUEST.
 7) SIZE ALL SECTIONS OF THE VENTING SYSTEM ON SANITARY
 RISER "B".
 8) SHT. P-2- REMOVE THE REFERENCE TO THE 2007 FBCAND
 INSERT 2010 FBC.
 9) AS DESIGNED, THE WATER CLOSET IN ROOM 186 ON
 SANITARY RISER "A" IS CREATING A HORIZONTAL WET VENT
 AND DOES NOT COMPLY WITH 2010 FPC SEC.909.1 AS TO THE
 TYPE AND NUMBER OF PLUMBING FIXTURES PERMITTED.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2014-10-20 Cont ID  
Sent By tklarge Date 2014-10-20 Time 10:26 Rev Time 0.00
Received By tklarge Date 2014-10-20 Time 10:26 Sent To  
Notes
2014-10-20 10:37:411) 5 % BUT NO LESS THAN ONE OF THE SINKS IN THE EXAM
 ROOMS AND OTHER ROOMS SHALL COMPLY WITH THE 2010
 FLORIDA ACCESSIBILITY CODE SECS. 212.3, 306, & 606.
 2) SHT. P-2 - SIZE ALL SECTIONS OF THE SANITARY AND
 WATER RISER DIAGRAMS. WPB AMEND. TO 2010 FBC SEC.
 107.2.1.
 3) SHT. P-2 - DRAINS FOR SINKS IN ROOMS 187 & 188 ARE
 DRAWN IN THE OPPOSITE DIRECTION OF FLOW AT THE
 CONNECTION TO THE EXISTING LINE.
 4) SHT. P-2 - THE HUB DRAIN IN ROOM #205 REQUIRES A
 TRAP SEAL PER THE 2010 FPC SECS. 1002.1, 1002.4.
 5) SHT. P-2 - THE BREAK ROOM SINK IS NOT SHOWN ON THE
 SANITARY RISER. WPB AMEND. TO 2010FBC SEC.107.2.1.
 6) THE SINK IN RM. #188 IS NOTED AS EXISTING ON THE
 SANITARY RISER BUT AS NEW ON THE WATER RISER. CLARIFY.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2015-03-12 Cont ID  
Sent By dkittred Date 2015-03-12 Time 11:31 Rev Time 0.00
Received By dkittred Date 2015-03-10 Time 09:11 Sent To  
Notes
2015-03-12 11:31:12PLANNING AND ZONING COMMENTS: ***FAILED***
  
 3/12/15
  
 1. WILL THERE BE ANY INCREASE IN BUILDING FOOTPRINT
 SQUARE FOOTAGE WITH THE PROPOSED FA?ADE IMPROVEMENT?
 PLEASE PROVIDE AN OVERLAY OF THE OLD AND NEW TO CONFIRM
 THE CHANGES.
  
 2. ADDITIONALLY, UNTIL THE FA?ADE IMPROVEMENT LOCATION
 IS CONFIRMED, IT IS UNCLEAR IF THERE IS ANY IMPACT TO
 THE PEDESTRIAN WALKWAY. IF THE FA?ADE LOCATION IS
 CHANGING RESULTING IN ANY DECREASE IN THE WIDTH OF THE
 COVERED WALKWAY AN ADDITIONAL REVIEW WILL BE REQUIRED
 TO ASSESS WALKWAY WIDTHS AND CONFLICTS WITH COLUMNS. AN
 INCREASE IN BUILDING FOOTPRINT MAY ALSO TRIGGER A MINOR
 PLANNED DEVELOPMENT AMENDMENT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved