2014-09-30 17:38:14BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- TALKED TO MR. DANIEL MUNNA. HE SAID THE APARTMENTS
 HAVE SUSPENDED CEILINGS. BUILDING PERMIT ISSUED WITH
 THE CONDITION THAT SUSPENDED CEILINGS ARE THERE.
 OTHERWISE, A DIFFERENT UNDERLAYMENT OR FIELD TEST MAY
 BE REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-09-30 Cont ID  
Sent By jgomez Date 2014-09-30 Time 16:25 Rev Time 0.00
Received By jgomez Date 2014-09-30 Time 16:01 Sent To  
Notes
2014-09-30 16:47:06RESIDENTIAL (R2) FLOORING, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- COPIES OF IMPACT SOUND TRANSMISSION TEST (ASTM E
 492) AND SOUND TRANSMISSION LOSS TEST (ASTM E 90) SHOW
 THAT THE TESTS WERE DONE FOR AN 8" CONCRETE SLAB WITH A
 SUSPENDED CEILING SYSTEM". IF THE PROPOSED INSTALLATION
 DOESN'T MATCH THIS TYPE OF FLOOR/CEILING ASSEMBLY, THEN
 THIS TEST CAN'T BE USED TO SHOW COMPLIANCE WITH THE
 SOUND TRANSMISSION REQUIREMENT OF SEC. 1207 OF 2010
 FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-09-30 Cont ID  
Sent By jgomez Date 2014-09-30 Time 17:33 Rev Time 0.00
Received By jgomez Date 2014-09-30 Time 17:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-30 Cont ID  
Sent By jgomez Date 2014-09-30 Time 16:14 Rev Time 0.00
Received By jgomez Date 2014-09-30 Time 16:01 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved