Plan Review Details - Permit 14090787
Plan Review Stops For Permit 14090787
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2014-09-29 Cont ID  
Sent By jgomez Date 2014-09-29 Time 14:13 Rev Time 0.00
Received By jgomez Date 2014-09-29 Time 14:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2014-09-26 Cont ID  
Sent By jgomez Date 2014-09-26 Time 17:24 Rev Time 0.00
Received By jgomez Date 2014-09-26 Time 17:24 Sent To  
Notes
2014-09-26 17:24:19RESIDENTIAL (R2) FLOORING, RE-SUBMITTAL BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- SOUND INSULATION PROFLEX MSC 90 INFORMATION
 SUBMITED:
  
 A) SOUND TRANSMISSION TEST (ASTM E 90) AND IMPACT SOUND
 TRANSMISSION TEST (ASTM E 492) INFORMATION SUBMITTED IS
 FOR AN 8" CONCRETE SLAB FLOOR-CEILING ASSEMBLY WITH A
 SUSPENDED CEILING SYSTEM. I CAN ISSUE THE PERMIT IF YOU
 CONFIRM THAT THIS IS THE TYPE OF FLOOR CEILING ASSEMBLY
 FOR THE PROPOSED INSTALLATION. OTHERWISE, SUBMITT
 PROPER TESTING INFORMATION MATCHING THE PROPOSED
 INSTALLATION AS REQUIRED BY SEC. 1207.2 AND 1207.3 OF
 2010 FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-09-26 Cont ID  
Sent By jgomez Date 2014-09-25 Time 16:35 Rev Time 0.00
Received By jgomez Date 2014-09-26 Time 14:59 Sent To  
Notes
2014-09-25 16:36:08RESIDENTIAL (R2) FLOORING, SECOND BUILDING REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- SOUND INSULATION MATERIALS: PROVIDE 2 COPIES OF THE
 FLAME SPREAD INDEX AND SMOKE- DEVELOPED INDEX TEST IN
 ACCORDANCE WITH ASTM E 84 OR UL 723 AS REQUIRED BY SEC.
 719.1 OF 2010 FBC.
  
 ***RESPONSE TO E-MAIL FROM MR. RICHARD MOYER:
  
 INFORMATION SUBMITTED DOESN'T PROVIDE ANY INFORMATION
 REGARDING THE ASTM E 84 OR UL 723 TEST TO SHOW
 COMPLIANCE WITH THE FLAME SPREAD INDEX AND
 SMOKE-DEVELOPED INDEX OF THE PROPOSED SOUND INSULATION
 MATERIAL. NEED TO PROVIDE COPIES OF SUCH TEST.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-09-24 Cont ID  
Sent By jgomez Date 2014-09-23 Time 18:18 Rev Time 0.00
Received By jgomez Date 2014-09-23 Time 17:41 Sent To  
Notes
2014-09-23 18:18:24RESIDENTIAL (R2) FLOORING, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- SOUND INSULATION MATERIALS: PROVIDE 2 COPIES OF THE
 FLAME SPREAD INDEX AND SMOKE- DEVELOPED INDEX TEST IN
 ACCORDANCE WITH ASTM E 84 OR UL 723 AS REQUIRED BY SEC.
 719.1 OF 2010 FBC.
  
 2- A) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS
 (STC) TEST SHOWING COMPLIANCE WITH ASTM E90 AS REQUIRED
 BY SEC. 1207.2 OF 2010 FBC..
 B) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS
 (IIC) TEST SHOWING COMPLIANCE WITH ASTM E 492 AS
 REQUIRED BY SEC. 1207.3 OF 2010 FBC.
  
 ***NOTE: INFORMATION SUBMITTED STATES "INDEPENDENT
 SOUND TESTED. IIC=70MIN STC=67MIN". BUT, THERE IS NO
 INFORMATION ABOUT THE INDEPENDENT TEST PERFORMED. NEED
 TO KNOW THE STANDARDS USED FOR THE TEST AND IF THE TEST
 WAS DONE WITH SUSPENDED CEILING ASSEMBLY OR NOT? AND
 THICKNESS OF CONCRETE SLAB, ETC. OTHERWISE IF ASSEMBLY
 DOESN'T MATCH PROPOSED APPLICATION, THEN IT MAY NOT BE
 USED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2014-09-29 Cont ID  
Sent By jgomez Date 2014-09-29 Time 14:13 Rev Time 0.00
Received By jgomez Date 2014-09-29 Time 14:04 Sent To  
Notes
2014-09-29 14:13:37E-MAIL FROM CONTRACTOR USING NATURAL CORK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-09-26 Cont ID  
Sent By jgomez Date 2014-09-26 Time 17:24 Rev Time 0.00
Received By jgomez Date 2014-09-26 Time 16:30 Sent To  
Notes
2014-09-26 16:31:53INCOMING SENT TO J. GOMEZ DESK .JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-09-25 Cont ID  
Sent By jgomez Date 2014-09-25 Time 16:36 Rev Time 0.00
Received By jgomez Date 2014-09-25 Time 17:08 Sent To  
Notes
2014-09-25 17:09:269/25/14 RECEIVED -EMAIL RESPONSE FROM RICHARD MOYER
 (CONTRACTOR).

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-23 Cont ID  
Sent By jgomez Date 2014-09-23 Time 17:41 Rev Time 0.00
Received By jgomez Date 2014-09-23 Time 17:41 Sent To  
Notes
***NONE***