Plan Review Details - Permit 14090650
| Plan Review Stops For Permit 14090650 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-11-03 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-11-04 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-11-03 |
Time |
10:18 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-10-02 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-10-02 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-02 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2014-10-02 09:56:41 | 1ST REVIEW: FBC 2010 | | | | | | R302.1 EXTERIOR WALLS. | | | CONSTRUCTION, PROJECTIONS, OPENINGS AND PENETRATIONS OF | | | EXTERIOR WALLS OF DWELLINGS AND ACCESSORY BUILDINGS | | | SHALL COMPLY WITH TABLE R302.1, FIRE-RESISTANT | | | CONSTRUCTION. | | | WITHIN 3', 1 HOUR-TESTED IN ACCORDANCE WITH ASTM E 119 | | | OR UL 263 WITH EXPOSURE FROM BOTH SIDES | | | THE FLORIDA GLASS WALL PROPOSED AT 1'0" FROM THE | | | PROPERTY LINE IS DOES NOT MEET THE ABOVE REQUIREMENT | | | AND DOES NOT APPEAR TO QUALIFY FOR EXCEPTION 7 AS | | | FOLLOWS: " SCREEN ENCLOSURE WALLS OF INSECT SCREENING | | | WITH A MAXIMUM OF 25 PERCENT SOLID FLEXIBLE FINISHES." | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-11-04 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-11-04 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-29 |
Time |
16:03 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-10-02 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2014-09-18 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-18 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2014-09-30 09:51:05 | 9/30 TO ZONING | | | | | 2014-09-18 13:24:14 | ROUTED TO BLDG $5000 & UNDER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-11-03 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2014-11-03 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2014-11-03 |
Time |
11:31 |
Sent To |
B1 |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-09-30 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2014-09-30 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2014-09-30 |
Time |
14:33 |
Sent To |
B1 |
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy