| Plan Review Stops For Permit 14090314 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-10-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-10-07 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-10-07 |
Time |
07:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-09-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-09-25 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-23 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-22 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-22 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-09-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-09-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-09-12 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2014-09-12 16:15:15 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | ADD ONE EXIT SIGN AT REAR HALLWAY AREA LEADING TO REAR | | | EXIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-10-14 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-14 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-03 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2014-10-03 16:54:28 | INCOMING SENT TO B-24. JW |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-29 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-29 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-10 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-09-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-09-25 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-25 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-30 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-09-30 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-09-30 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-25 |
|
|
Cont ID |
|
| Sent By |
rbergsma |
Date |
2014-09-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-09-30 |
Time |
14:13 |
Sent To |
P |
|
| Notes |
| 2014-09-25 13:40:26 | PLEASE REVIEW AND RESPOND TO FBC-M 510.5.3 AND M | | | 510.5.4, SEE MARKED UP M-1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-10-14 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-14 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-14 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-09-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-09-30 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-29 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2014-09-29 10:50:57 | 1) SUBMIT 2 COPIES OF THE MANUFACTURER'S SPECIFICATIONS | | | AND INSTALLATION INSTRUCTIONS FOR THE PEDICURE CHAIRS. | | | WPB ADMIN. AMEND. TO 2010 FBC SEC. 107.2.1. | | | 2) SHOW THE CLEAR FLOOR SPACE REQUIRED FOR ALL THE | | | FIXTURES ON BOTH SETS OF PLANS. THE CLEAR FLOOR SPACE | | | SHALL COMPLY WITH THE 2010 FL. ACCESSIBILITY CODE | | | SEC.305.1. | | | 3) THE REQUIRED CLEAR FOR SPACE FOR THE DRINKING | | | FOUNTAIN SHALL BE CENTERED ON THE UNIT. FAC SEC.602.2. | | | 4) ONE OF THE HAND SINKS SHALL COMPLY W/ SECS.212.3 & | | | 606 OF THE 2010 FAC. | | | 5) THE WASHER & DRYER SHALL COMPLY W/2010 FAC | | | SEC.611.2, 611.3, 611.4. | | | 6) SHT. P-1 - SIZE THE STUDOR VENTS ON THE NEW SANITARY | | | DRAIN. VENT SIZE SHALL COMPLY W/TABLE 916.1 OF 2010 FL. | | | PLUMBING CODE. | | | 7) CLEANOUTS ARE REQD. IN THE WASTE AND VENT STACKS PER | | | 2010 FPC SEC.708.3.4. | | | 8) DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR | | | CLEARANCE REQUIRED FOR ANY FIXTURE PER THE 2010 FAC | | | SEC. 603.2.3. | | | | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2014-09-22 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2014-09-22 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2014-09-22 10:15:12 | PROJECT DOES NOT EXCEED 50 PERCENT OF THE VALUE OF THE | | | STRUCTURE. | | | | | | ZONED: GC | | | PROPOSED USE: #23: PERSONAL SERVICES. | | | | | | | | 2014-09-19 16:14:24 | 9/19/14 |
|
|