Plan Review Details - Permit 14090140
Plan Review Stops For Permit 14090140
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-11-19 Cont ID  
Sent By jgomez Date 2014-11-18 Time 19:01 Rev Time 0.00
Received By jgomez Date 2014-11-18 Time 19:01 Sent To  
Notes
2014-11-18 19:03:17BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE 2 COPIES OF PRODUCT APPROVAL FOR THE TERRACE
 UNDERLAYMENT SPECIFIED ON PLANS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-09-25 Cont ID  
Sent By jgomez Date 2014-09-25 Time 17:28 Rev Time 0.00
Received By jgomez Date 2014-09-25 Time 17:22 Sent To  
Notes
2014-09-25 17:36:42RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR NEW MASTER BEDROOM DOOR AS SHOWN ON
 PLANS.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVAL AS
 REQUIRED BY SEC. 107.3.4.1 OF CITY AMENDMENTS TO FBC.
  
 3- DESIGNER OF RECORD TO SPECIFY THE DESIGN PRESSURES
 FOR NEW MASTER BEDROOM EXTERIOR DOOR. SEC. R301.1 OF
 2010 FBC.
  
 4- PROPOSED SECOND FLOOR TERRACE AND EXISTING FIREPLACE
 TERMINATION CREATES A HAZARD. REVISE PLANS TO SHOW
 COMPLIANCE WITH THE FIREPLACE TERMINATION AS REQUIRED
 BY SEC. R1003.9.
  
 5- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 INSTALLATION OF THE NEW T & G CYPRESS CEILING AND CROWN
 MOLDING IN THE NEW LOGGIA CEILING. SEC. R703.1.3.
  
 6- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 TERRACE FLOORING AS REQUIRED BY SEC. R903.1.
  
 7- SHEET S100: ENGINEER TO CLARIFY WHY THE DESIGN
 CRITERIA FOR THIS NEW LOGGIA AND TERRACE IS "ENCLOSED".
 SEE DEFINITION FOR ENCLOSED BUILDING SEC. 26.2 OF ASCE
 7-10 AND REVISE INFORMATION AND DESIGN PRESSURES AS
 REQUIRED.
  
 8- BASED ON THE SPECIAL TYPE OF CONSTRUCTION SHOWN ON
 PLANS THE VALUATION DECLARED IN THE PERMIT APPLICATION
 IS TOO LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND THE PROFESSIONAL
 DESIGNERS FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS TO FBC. UPDATE VALUATION AS REQUIRED.
  
 9- BASED ON THE SPECIAL TYPE OF CONSTRUCTION SHOWN ON
 PLANS (8" ELEVATED CONCRETE SLAB WITH FC = 5000 PSI) AN
 SPECIAL INSPECTOR WILL BE REQUIRED BY SEC. 110.3.9 CITY
 AMENDMENTS TO FBC.
  
 10- BASED ON THE SPECIAL TYPE OF CONSTRUCTION SHOWN ON
 PLANS ENGINEER OF RECORD TO PROVIDE SHORING DETAILS AND
 SPECIFICATIONS. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 ***NOTES:
 * PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ** PLEASE REMOVE AND REPLACE ALL REVISED SHEETS TO
 EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-11-19 Cont ID  
Sent By rmcdouga Date 2014-11-19 Time 07:27 Rev Time 0.00
Received By rmcdouga Date 2014-11-19 Time 07:21 Sent To  
Notes
2014-11-18 19:02:47NEW ELECTRICAL SHEETS SUBMITTED., JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2014-10-11 Cont ID  
Sent By rmcdouga Date 2014-10-11 Time 12:17 Rev Time 0.00
Received By rmcdouga Date 2014-10-11 Time 12:04 Sent To  
Notes
2014-10-11 12:17:45APPROVED WITH EXCEPTION.
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S).
 1) NEC 210.52(E) OUTDOOR OUTLETS. (3) BALCONIES, DECKS
 AND PORCHES THAT ARE ACCESSIBLE FROM INSIDE THE
 DWELLING UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET
 INSTALLED WITHIN THE PERIMETER OF THE BALCONY, DECK OR
 PORCH. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN
 6.5 FT ABOVE THE BALCONY, DECK OR PORCH SURFACE.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-11-19 Cont ID  
Sent By jgomez Date 2014-11-19 Time 07:39 Rev Time 0.00
Received By jgomez Date 2014-10-31 Time 06:31 Sent To  
Notes
2014-11-01 06:32:08GAVE TO GOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-10-11 Cont ID  
Sent By rmcdouga Date 2014-10-11 Time 12:17 Rev Time 0.00
Received By rmcdouga Date 2014-09-08 Time 11:06 Sent To  
Notes
2014-09-09 11:06:38SENT TO R3 SHELF FOR REVIEW. JG.
2014-09-04 14:27:49ROUTED TO ELECTRICAL $5000 & UNDER

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2014-09-25 Cont ID  
Sent By jgomez Date 2014-09-25 Time 17:36 Rev Time 0.00
Received By jgomez Date 2014-09-25 Time 17:36 Sent To  
Notes
2014-09-25 17:39:03NO FEES DUE. STAMPED BY D.B. (PERMIT TECH) ON SEP 04
 2014. SEE SHEET A000. JG.

Review Stop Z ZONING
Rev No 1 Status P Date 2014-09-11 Cont ID  
Sent By sgraham Date 2014-09-11 Time 16:12 Rev Time 0.00
Received By sgraham Date 2014-09-11 Time 16:12 Sent To  
Notes
2014-09-11 15:15:099/11/14