| Plan Review Stops For Permit 14090135 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-09-17 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-17 |
Time |
10:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-10-02 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-10-02 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-10-02 |
Time |
10:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-09-16 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2014-09-16 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2014-09-16 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2014-09-16 14:56:59 | 14090135 | | | 6901 OKEECHOBEE BLVD #81 | | | RESTAURANT REMODEL | | | | | | PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING | | | REVIEW COMMENTS. | | | | | | THE TOTAL SCOPE OF THE ELECTRICAL WORK IS NOT CLEAR. | | | ARE THE PANELS NEW OR EXISTING? SHOW ALL NEW CIRCUITS | | | AND OUTLETS. PROVIDE AN ELECTRICAL RISER SHOWING | | | EXISTING AND NEW WORK ANDLOCATION OF MAIN SERVICE | | | DISCONNECTS. NEC 215.5 | | | | | | VERIFY A SAFETY LABELING SCHEDULE FOR FLASH PROTECTION | | | FOR THE ELECTRIC SERVICE, PANEL BOARDS AND MAIN | | | DISCONNECTING MEANS HAS BEEN PROVIDED. NEC 110.16, | | | 110.22 | | | | | | PROVIDE A LIGHTING DENSITY SUMMARY ON THE ELECTRIC PLAN | | | WHICH SHOWS COMPLIANCE WITH THE FLORIDA BUILDING ENERGY | | | CODE REQUIREMENTS. FBC ENERGY CONSERVATION 505.5; | | | 505.5.3; T. 505.5.3 | | | | | | PROVIDE A SIGN CIRCUIT AND DISCONNECT. NEC 600.5 | | | | | | CONFIRM THAT THE INTERIOR AND EXTERIOR LIGHTING | | | CONTROLS PROVIDED FUNCTION IN ACCORDANCE WITH THE | | | FLORIDA ENERGY CODE. EXTERIOR AUTOMATIC CONTROLS SHALL | | | BE CAPABLE OF RETAINING PROGRAMMING AND THE TIME | | | SETTING DURING LOSS OF POWER FOR A PERIOD OF AT LEAST | | | 10 HOURS. VERIFY THE LIGHTING AND SIGN TIME CLOCKS HAVE | | | BATTERY BACKUP. FBC ENERGY CONSERVATION 505.2 | | | | | | | | | ROBERT LECKY, CBO | | | ELECTRICAL PLANS REVIEW | | | 561-373-3701 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-09-10 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-09-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-09-09 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2014-09-10 10:55:53 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF THE | | | FIRE ALARM AND SPRINKLER SYSTEM FOR CODE COVERAGE AND | | | COMPLIANCE. | | | | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS, | | | SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE | | | WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL | | | AND COMPLETE PROTECTION IS RETURNED. | | | | | | ADD EXITS SIGNS IN THE PATH OF EGRESS AS SHOWN ON THE | | | LIFE SAFETY AND ELECTRICAL DRAWINGS WHERE INDICATED. | | | | | | THE HOOD SYSTEM AND FIRE SUPPRESSION SYSTEM SHALL BE | | | DONE UNDER SEPARATE SHOP DRAWINGS. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2014-10-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-21 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-20 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2014-10-28 10:06:04 | SEPARATE PERMIT REQD. FOR GAS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2014-10-21 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-21 |
Time |
06:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-16 |
Time |
10:52 |
Sent To |
P |
|
| Notes |
| 2014-10-17 10:52:57 | TO T.L'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-10-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-10-03 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-09-30 |
Time |
15:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-22 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-04 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-09-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-09-17 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-09-17 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-10-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-10-03 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-10-03 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
rbergsma |
Date |
2014-09-22 |
Time |
|
Rev Time |
1.50 |
| Received By |
rbergsma |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-09-22 10:15:43 | M-1, (1) THERE ARE 3 BATH FANS INDICATED ON THE AIR | | | BALANCE CHART, PROVIDE LOCATION OF 3RD BATH. | | | (2) THERE ARE A TOTAL OF 5 MUA FANS ON THE DRAWING, | | | THERE ARE 6 ON THE AIR BALANCE CHART ? | | | (3) AGAIN THE AIR BALANCE CHART INDICATES 10 TEPPAN | | | YAKI EXHAUST FANS, ONLY 8 ARE SHOWN? | | | (4) MUA DUCT AND FANS ARE SHOWN BETWEEN THE TEPPAN YAKI | | | HOODS BUT ARE REMOTE TO THE EXHAUST ON THE ROOF, | | | INDICATE DUCT AND SIZES | | | AND ROUTING ON PLANS. | | | (5) WILL THE MUA UNIT(S) PROVIDE 100% OF THEIR CAPACITY | | | IF ONLY ONE TEPPAN YAKI GRILL IS IN OPERATION OR IS IT | | | A TWO SPEED STAGGED OPERATION | | | (6) PROVDE PARAPET WALL HEIGHT BEHIND MAIN HOOD OR | | | STRUCTURAL RAILING DETAIL | | | M-2 (1) PROVIDE DETAIL OF GREASE DUCT PENETRATION THRU | | | CEILIN, WOOD TRUSSES AND ROOF ASSEMBLY (NFPA 96) | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2014-10-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-21 |
Time |
06:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-20 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2014-10-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-10-02 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-10-02 |
Time |
06:39 |
Sent To |
|
|
| Notes |
| 2014-10-02 07:49:02 | 1) 2ND REQUEST - SUBMIT MANUF. SPECIFICATION SHEETS FOR | | | THE HIBACHI TABLE. THE TABLES SHALL BE LISTED AND | | | LABELED PER THE 2010 FLORIDA FUEL GAS CODE SEC. 301.3. | | | THE SHEETS THAT WERE SUBMITTED DO NOT SHOW THAT THE | | | TABLES ARE LISTED AND LABELED. | | | 2) YOU HAVE ADDED A TABLE ABOVE THE GAS RISER THAT | | | READS "IRON PIPE SIZE". WHAT IS THE REASON FOR THIS | | | TABLE? | | | 3) SUBMIT TWO COPIES OF THE APPLICABLE GAS SIZING | | | TABLES THAT ARE BEING USED FOR THIS PROJECT. | | | 4) SHT. P-1 - I HAVE REFERENCED THE 2010 EDITION | | | FLORIDA FUEL GAS CODE IN MY REVIEW COMMENTS AND YOU | | | HAVE REFERENCED THE 2006 IFGC. REVISE THE NOTE TO | | | COMPLY W/ THE 2010 FLORIDA FUEL GAS CODE. | | | 5) YOUR RESPONSE TO MY FIRST REVIEW COMMENT #5 REFERS | | | TO FLEXIBLE GAS PIPING WITH A POLYETHYLENE SLEEVE. THIS | | | DOES NOT SATISY THE REQUIREMENT FOR CONDUIT. COMPLY | | | WITH THE 2010 FLORIDA FUEL GAS CODE 404.12.2. TRACPIPE | | | ALSO REQUIRES THE CONDUIT. YOUR RESPONSE REFERS TO | | | 'SUBMITTED ATTACHMENT." THERE WAS NO ATTACHMENT FOR | | | TRACPIPE. | | | 6) SHOW THE LENGTH OF EACH SECTION OF TRACK PIPEON THE | | | PLAN AND THE RISER. | | | 7) SUBMIT THE CORRESPONDING EHD NUMBER FOR THE TRAC | | | PIPE FROM THE APPLICABLE SIZING TABLE BEING USED. | | | 8) PLEASE SHOW THE SIZE OF THE EXISTING GREASE TRAP. | | | 9) CLARIFY THE SIZE OF THE WATER HEATER. THE PLAN SHOWS | | | "7 I". CLARIFY. | | | 10) INDICATE ON THE PLAN WHAT WILL BE THE USE OF THE | | | TWO ADDED SINKS? |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-09-19 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-19 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-19 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2014-09-19 14:27:38 | WPB AMEND. TO 2010 FBC SEC. 107.2.1. | | | 1) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR THE | | | HIBACHI TABLES. THE TABLES SHALL BE LISTED AND LABELED | | | PER THE 2010 FLORIDA GAS CODE 301.3. | | | 2) THE ADDED GAS LOAD FOR THE HIBACHI TABLES HAS NOW | | | MADE THE ENTIRE GAS SYSTEM UNDERSIZED. THE GAS SYSTEM | | | SIZING SHALL COMPLY WITH TABLE 402.4 (2) AS SPECIFIED | | | ON THE PLANS FOR A TOTAL RUN OF 128 FT. IF YOU INCREASE | | | THE GAS PRESSURE TO A 2 PSI SYSTEM AND SIZE THE SYSTEM | | | TO TABLE 402.4 (30 YOU WILL BE IN COMPLIANCE. | | | 3)SHT. P-2 - THE 3" WASTE LINE WITH THE AIR ADMITTANCE | | | VALVES FROM THE HAND SINKS TO THE EXISTING GREASE TRAP | | | REQUIRES A VENT TO THE OPEN AIR PER THE 2010 FBCP | | | SEC.917.7. THE VENT COULD BE INSTALLED AGAINST THE | | | EXTERIOR WALL ON THE OUTSIDE OF THE BUILDING TO COMPLY | | | WITH THIS CODE SECTION. | | | 4) IDENTIFY THE SQUARE ON THE GAS PIPING DIAGRAM WITH | | | THE LETTERS "GS" IN IT. | | | 5) GAS PIPING UNDER THE SLAB TO THE HIBACHI TABLES | | | SHALL BE ENCASED IN CONDUIT PER THE 2010 FBCG | | | SEC.404.12.2. SUBMIT A DETAIL FOR THIS INSTALLATION | | | SHOWING THE SIZE OF THE CONDUIT. THE CONDUIT SHALL | | | TERMINATE IN AN ACCESSIBLE PORTION OF THE BUILDING. | | | 6) SUBMIT A SANITARY AND WATER RISER FOR THE PLUMBING | | | WORK TO BE DONE. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-09-11 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2014-09-11 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2014-09-11 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|