Plan Review Details - Permit 14090114
| Plan Review Stops For Permit 14090114 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-10-24 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-10-24 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-24 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-09-30 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-30 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-30 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2014-09-30 10:48:59 | 9/30/2014 | | | PROJECT: SERVICE CHANGE + SMOKE DETECTORS. | | | PERMIT#: 14090114 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE PANEL SCHEDULE FOR NEW 200AMP. MB PANEL. WPB | | | AMENDMENTS TO FBC 107.3.2 | | | | | | 2) PROVIDE SIZE OF GROUNDING ELECTRODE CONDUCTOR. NEC | | | 250.66 | | | | | | 3) PROVIDE MULTI-SYSTEM BONDING STRIP AT GROUNDING | | | ELECTRODE SYSTEM. NEC 250.94 | | | | | | 4) PROVIDE FLOOR PLAN TO INDICATE LOCATION OF SMOKE | | | DETECTORS IN COMPLIANCE WITH FBC 314-315 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-10-24 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-10-24 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-10-23 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2014-10-23 13:40:46 | TO DAH DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-30 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-30 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-04 |
Time |
11:27 |
Sent To |
|
|
| Notes |
| 2014-09-04 11:30:18 | <5000 ELEC |
|
|
|