Plan Review Details - Permit 14090074
| Plan Review Stops For Permit 14090074 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-23 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-23 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2014-09-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-08 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2014-09-08 10:04:10 | 1) SUBMIT 2 COPIES OF SIGNED & SEALED DRAWINGS BY | | | A.GEZELMAN, P.E. PER THE FL. ADMIN. CODE RULE | | | 61G15-23.002. REFER TO THE NOTE IN THE UPPER RIGHT HAND | | | CORNER OF THE PLAN THAT STATES" VOID WITHOUT RAISED OR | | | ELECTRONIC SEAL.MAY NOT BE USED FOR PLANS ON FILE.EVERY | | | PERMIT PULLED REQUIRES A SEALED ELECTRONIC PLAN OR | | | SEALED ORIGINAL PAPER COPY OF THIS PLAN." | | | 2) PLEASE SUBMIT TWO COPIES OF THE DRAWING BY A. | | | GEZELMAN THAT ARE LEGIBLE. THE PRINTING IS SO SMALL IT | | | IS EXTREMELY DIFFICULT TO READ. WPB AMENDMENTS TO 2010 | | | FBC SEC. 107.2.1. | | | | | | PLAN REVIEW | | | TIM LARGE- | | | CITY OF WEST PALM BEACH. | | | TEL:561-805-6692 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-08 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-08 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2014-09-08 10:27:08 | DATE: 9/8/2014 | | | PROJECT: SOLAR WATER HEATER | | | PERMIT#: 14090074 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | A SEPARATE ELECTRICAL PERMIT APPLICATION IS REQUIRED | | | FOR THE INSTALLATION OF THE REQUIRED 120V RECEPTACLE | | | OUTLET IS ONE IS NOT READILY AVAILABLE FOR THE | | | INSTALLATION OF THE CORD CONNECTED SYSTEM. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-23 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-17 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2014-09-22 10:23:29 | 9/22 TO TL DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-07 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-03 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2014-09-03 16:20:02 | TO PLUMBING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-09-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-23 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-23 |
Time |
11:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2014-09-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2014-09-07 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2014-09-07 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2014-09-07 10:34:49 | 1) SUBMIT 2 COPIES OF SIGNED & SEALED DRAWINGS BY | | | A.GEZELMAN, P.E. PER THE FL. ADMIN. CODE RULE | | | 61G15-23.002. REFER TO THE NOTE IN THE UPPER RIGHT HAND | | | CORNER OF THE PLAN THAT STATES" VOID WITHOUT RAISED OR | | | ELECTRONIC SEAL.MAY NOT BE USED FOR PLANS ON FILE.EVERY | | | PERMIT PULLED REQUIRES A SEALED ELECTRONIC PLAN OR | | | SEALED ORIGINAL PAPER COPY OF THIS PLAN." | | | 2) PLEASE SUBMIT TWO COPIES OF THE DRAWING BY A. | | | GEZELMAN THAT ARE LEGIBLE. THE PRINTING IS SO SMALL IT | | | IS EXTREMELY DIFFICULT TO READ. WPB AMENDMENTS TO 2010 | | | FBC SEC. 107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE- | | | CHIEF PLUMBING INSPECTOR | | | TEL:561-805-6692 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
|