Plan Review Details - Permit 14090065
Plan Review Stops For Permit 14090065
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2014-12-01 Cont ID  
Sent By shill Date 2014-12-01 Time 11:52 Rev Time 0.00
Received By shill Date 2014-12-01 Time 11:52 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2014-11-08 Cont ID  
Sent By shill Date 2014-11-08 Time 15:59 Rev Time 0.00
Received By shill Date 2014-11-08 Time 15:59 Sent To  
Notes
2014-11-08 16:03:55****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FROM PREVIOUS LIST:
  
 1. CLEAR OPENINGS FOR THE PROPOSED WINDOWS STATED ARE
 NOT POSSIBLE. CLEAR OPENING PROPOSED IS OVER HALF OF
 THE WINDOW HEIGHT. PROVIDE CLEAR OPENING FROM THE
 MANUFACTURER. FBC R310, FBC EB 604.1
  
 2ND REVIEW:
  
 BASED ON JELD-WEN'S WEBSITE, FOR A FIN INSTALLATION,
 THE MEETING RAIL (1.25") AND FRAME (1.25"+.75"+1 3/16"
 = 3 3/16"), APPROXIMATELY 4" SHOULD BE DEDUCTED FROM
 HALF THE WINDOW SIZE, GIVING AN APPROXIMATE CLEAR
 OPENING (AKA "DAYLIGHT OPENING") OF 20" HIGH. THIS
 EXCEEDS THE 5% CLEAR OPENING REDUCTION PERMITTED.
  
 HTTP://WWW.JELD-WEN.COM/CATALOG/WINDOWS/PREMIUM-ATLANTI
 C/ALUMINUM/SINGLE-HUNG
  
 FOR THE 48" HIGH WINDOW, NEW DIMENSION FOR CLEAR
 OPENING NOT PROVIDED. HOWEVER, USING THE DIMENSIONS
 FROM THEIR WEBSITE FOR A FIN WINDOW (FLANGE FRAME IS
 LARGER, SO AN EVEN SMALLER CLEAR OPENING WOULD RESULT),
 THE PROPOSED WINDOW EXCEEDS THE 5% REDUCTION.
  
 11/12 - SPOKE WITH APPLICANT; SUGGESTED A CASEMENT
 WINDOW FOR THIS OPENING
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2014-10-22 Cont ID  
Sent By shill Date 2014-10-22 Time 14:28 Rev Time 0.00
Received By shill Date 2014-10-22 Time 14:28 Sent To  
Notes
2014-10-22 14:31:38****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. CLEAR OPENINGS FOR THE PROPOSED WINDOWS STATED ARE
 NOT POSSIBLE. CLEAR OPENING PROPOSED IS OVER HALF OF
 THE WINDOW HEIGHT. PROVIDE CLEAR OPENING FROM THE
 MANUFACTURER. FBC R310, FBC EB 604.1
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-09-30 Cont ID  
Sent By shill Date 2014-09-30 Time 17:54 Rev Time 0.00
Received By shill Date 2014-09-30 Time 17:54 Sent To  
Notes
2014-09-30 17:57:03****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS,
 SIZES, WINDOW TYPE, ROOM DESIGNATIONS.
  
 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND
 OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 604.1. THE
 CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%.
  
 TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION
 NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN
 HEIGHT:
  
 STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS
 - AWNING, CASEMENT, SINGLE HUNG?
  
 STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE.
 CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE
 WINDOW IS FULLY OPEN.
  
 STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE.
 THIS CAN BE OBTAINED FROM THE MANUFACTURER.
  
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2014-12-02 Cont ID  
Sent By fmittner Date 2014-12-02 Time 16:23 Rev Time 0.00
Received By fmittner Date 2014-12-02 Time 16:23 Sent To  
Notes
2014-12-02 16:24:30READY TO ISSUE. BROUGHT TO BLDG DEPT.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-09-15 Cont ID  
Sent By fmittner Date 2014-09-15 Time 15:36 Rev Time 0.00
Received By fmittner Date 2014-09-15 Time 15:36 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By shill Date 2014-12-01 Time 11:53 Sent To  
Notes
2014-12-01 11:53:21TO ZONING
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2014-11-08 Cont ID  
Sent By shill Date 2014-11-08 Time 16:03 Rev Time 0.00
Received By shill Date 2014-10-28 Time 17:05 Sent To  
Notes
2014-10-28 17:06:20RE-SUBMITTAL SENT TO SAMANTHA HILL FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-10-22 Cont ID  
Sent By shill Date 2014-10-22 Time 14:31 Rev Time 0.00
Received By shill Date 2014-10-15 Time 13:35 Sent To  
Notes
2014-10-15 13:40:24TO SH DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-09-30 Cont ID  
Sent By shill Date 2014-09-30 Time 17:58 Rev Time 0.00
Received By shill Date 2014-09-30 Time 17:58 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved