Plan Review Details - Permit 14090043
| Plan Review Stops For Permit 14090043 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-10-26 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-10-26 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-26 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-10-07 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-10-07 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-07 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2014-10-07 14:01:24 | 1ST REVIEW: FBC 2010 | | | | | | THE APPLICATION DOES NOT QUALIFY FOR THE OWNER BUILDER | | | EXEMPTION PURSUANT TO FS 489. A QUALIFIED LICENSED | | | CONTRACTOR IS REQUIRED. | | | | | | THE APPLICATION IS UNDER VALUED, FBC 109.3 BUILDING | | | PERMIT VALUATION. FOR PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE | | | TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, | | | INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND | | | DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT; | | | EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | | MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE | | | CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET | | | BY THE BUILDING OFFICIAL. | | | | | | THE PRODUCT FL15558.1, JEN WELD DOOR HAS NO EVIDENCE OF | | | REVIEW BY REGINALD COX. FBC 107.3.4 - PROVIDE PRODUCT | | | APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. | | | | | | THE PLAN IS UNCLEAR AND NOT APPARENTLY INCONSISTANT | | | WITH PLANS ON RECORD. PLEASE FURTHER CLARIFY THE SCOPE | | | OF WORK. THE ELECTRICAL NOTES INDICATE A NEW ADDITION | | | WHEREAS THE PLAN OTHERWISE INDICATES THE SPACE IS | | | EXISTING. | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-10-07 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-10-07 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-07 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-10-07 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-10-07 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-03 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2014-09-03 09:13:39 | ZONING | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2014-10-26 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-10-26 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-26 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-10-07 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-10-07 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-07 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2014-10-07 13:16:02 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | | WITH A COPY OF RECEIPT AS APPLICABLE. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2014-10-26 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-10-26 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-26 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2014-10-07 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-10-07 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-10-07 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2014-10-07 14:05:21 | 1ST REVIEW: FBC 2010 | | | | | | THE ROOFING PRODUCT NOA-12-0716.18 DOES NOT CLEARLY | | | BEAR EVIDENCE OF REVIEW BY REGINALD COX. FBC 107.3.4 - | | | PROVIDE PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE | | | REGULATED BY FAC RULE 9N-3 REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD. ADDITIONALLY THE | | | DESIGNER SHALL PROVIDE DESIGN PRESSURE CALCULATIONS FOR | | | ENHANCED FASTENING FOR THE PRODUCT PER LIMITATION #7 AS | | | MAY BE NEEDED. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-10-07 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2014-10-07 |
Time |
12:50 |
Rev Time |
0.00 |
| Received By |
sgraham |
Date |
2014-10-07 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
|