| Plan Review Stops For Permit 14090024 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-28 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-28 |
Time |
12:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-10 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-09 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2014-09-10 16:26:30 | 1ST REVIEW: FBC 2010 | | | | | | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | THE EXAMINATION OF THE DOCUMENTS BY THE | | | BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM | | | CRITERIA AND DOCUMENTS: A FLOOR PLAN; SITE | | | PLAN; FOUNDATION PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS | | | LAYOUT; ALL FENESTRATION PENETRATIONS; | | | FLASHING; AND ROUGH OPENING DIMENSIONS; AND ALL | | | EXTERIOR ELEVATIONS: | | | | | | PROVIDE STRUCTURAL DETAILS AND CLARIFY CONFLICTS IN THE | | | PLAN AS FOLLOWS: | | | | | | DETAIL THE RETROFIT OPENINGS FOR WINDOWS IDENTIFIED TO | | | BE RELOCATED ON SHEET A-3 & A-4. | | | PROVIDE DOCUMENTTATION FOR "WINDOWS TO BE RELOCATED" TO | | | DEMONSTRATE SUCH WINDOWS COMPLY WITH THE FLORIDA | | | BUILDING CODE. | | | DETAIL THE CLOSING OF OPENING OF FORMER WINDOWS. | | | DETAIL THE NEW OPENINGS FOR NEW WINDOWS AND DOORS ON | | | SHEET A-3 &A-4. | | | CLARIFY THE ROOF SHEATHING TYPE. THE PLAN CONLICTS | | | INDICATING 1/2" AND 5/8." | | | CLARIFY ALL SHEATHING NAILING SPECIFICATIONS. ARE RING | | | SHANK NAILS INTENDED? NOTES REFER TO A DETAIL WHICH | | | APPARENTLY IS NOT UPON THE PLAN. | | | CLARIFY THE PORCH CORNER POST. IS IT A 3" PIPE, OR A | | | 6X6 WOOD POST? | | | | | | THANK YOU, | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-09-27 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-27 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-27 |
Time |
14:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-02 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-02 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2014-09-02 16:45:22 | DATE: 9/2/2014 | | | PROJECT: 918 30TH ST | | | PERMIT#: 14090024 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) IT APPEARS BY WHAT IS INDICATED ON THE PLANS THE | | | ELECTRICAL PANEL IS LOCATED IN THE KITCHEN UTILITY | | | CLOSET BEHIND WASHER/DRYRER. THE ELECTRICAL PANEL | | | REQUIRES CLEAR UNOBSTRUCTED WORKING ACCESS. NEC 110.26. | | | REVVISE PLANS FOR CODE COMPLIANCE. | | | | | | 2) ONE GFI RECEPTACLE IS REQUIRED WITHIN SIGHT OF | | | MECHANICAL EQUIPMENT. REVISE PLANS TO INDICATE REQUIRED | | | OUTLETS BY MECHANICAL EQUIPMENT. NEC 210.63 SEE | | | 210.8(A)(3), | | | | | | 3) SMOKE/CO DETECTORS ARE REQUIRED PER THE FBC-R 314, | | | 315. IDENTIFY THE REQUIRED SMOKE DETECTORS. | | | FBC-RESIDENTIAL 314.3 AND 314.3.1 | | | | | | 4) PROVIDE A RISER DIAGRAM, PANEL SCHEDULE, LOAD | | | CALCULATION AND SITE PLAN TO INDICATE THE LOCATION OF | | | THE ELECTRICAL SERVICE AND MAIN DISCONNECT FBC 107.2.1, | | | NEC 230.70 | | | | | | 5) TWO SETS OF PLANS AND SPECIFICATIONS ARE REQUIRED | | | FOR REVIEW. WPB FBC 107.3.5 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT | | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | | ITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-09-26 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-28 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-09-26 |
Time |
15:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-09-02 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-09-02 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-28 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-26 |
Time |
15:03 |
Sent To |
HIST |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-10 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-02 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2014-09-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-28 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-27 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2014-09-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-10 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-10 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2014-09-10 13:09:07 | 1ST REVIEW: FBC 2010 | | | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2014-09-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-28 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-28 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2014-09-28 12:42:04 | PROVISO: | | | | | | THE BREAKER SIZES SPECIFIED ON THE PANEL SCHEDULE ARE | | | NOT THE SAME AS ON THE A/C SHEET FOR THE AHU & | | | CONDENSER. PLEASE ADVISE IF YOU WOULD LIKE TO RESOLVE | | | THIS AS A REVISION LATER, OR A RE-SUBMITTAL PRIOR TO | | | ISSUANCE. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2014-09-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-10 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-10 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2014-09-10 14:01:49 | 1ST REVIEW: FBC 2010 | | | | | | FBC- 107.3.5.3 - PROVIDE A LARGER, MORE LEGIBLE | | | MECHANICAL PLAN TO SHOW SUPPLY DUCTS PER FBC-R M16 & | | | BATH EXHAUST PER FBC-R M15. | | | | | | FBC 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2014-09-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-28 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-28 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2014-09-28 13:02:36 | 1ST REVIEW: FBC 2010 | | | | | | REVIEW OF 9/10/14 WAS ERRONEOUS. | | | | | | PROVISIONALLY APPROVED; REVISION REQUIRED FOR PLUMBING | | | RISER. FBC 107. MINIMUN PLAN REVIEW CRITERIA. | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-10 |
Time |
13:11 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-10 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2014-09-10 13:11:56 | THERE ARE NO PROPOSED PLUMBING MODIFICATIONS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2014-09-28 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2014-09-28 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2014-09-28 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2014-09-28 12:45:29 | ROOFING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2014-09-26 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-09-26 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-09-26 |
Time |
15:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2014-09-02 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2014-09-02 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|