| Plan Review Stops For Permit 14081169 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2015-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-02-26 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-02-26 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2015-02-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-02-24 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-02-24 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2015-02-24 10:44:57 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | | | | 1. PLEASE REVISE THE INSTALLATION SCHEDULE AS FOLLOWS: | | | | | | ONLY ONE OPENING SHOWN, BUT MULTIPLE WINDOWS ARE BEING | | | INSTALLED. REVISE TO INCLUDE ALL OPENINGS. OK TO USE | | | "WORST CASE" (SAME INFORMATION) FOR ALL OPENINGS. | | | | | | SHUTTER MOUNTING CONNECTION TYPE SHOULD CORRELATE WITH | | | THE ANCHOR CHARTS (EXAMPLE - C1, C2, C3, C4, C5), SEE | | | SHEET 4 | | | | | | ANCHOR SPACING WAS LEFT BLANK, NEED PROPOSED ANCHOR | | | SPACING | | | | | | ONLY ONE SET PROVIDED; TWO REQUIRED | | | | | | 2. THE NOA PROVIDED IS DIFFICULT TO READ AS IT WAS | | | PRINTED "PORTRAIT" RATHER THAN "LANDSCAPE". PROVIDE | | | LEGIBLE SHEETS, FBC 107. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-01-20 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-20 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2015-01-20 09:08:28 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | | | 2. THE STORM PANEL NOA NUMBER ON THE PLAN IS NOT | | | CONSISTENT WITH THE NUMBER OF THE PRODUCT APPROVAL | | | SUBMITTED, FBC 107. PLEASE CORRELATE. | | | | | | 3. PLAN DOES NOT INDICATE WHERE THE INFILL DETAIL 2-A1 | | | WILL BE INSTALLED, FBC 107. | | | | | | 4. BOND BREAK REQUIRED, REVISE INFILL DETAIL 2-A1, FBC | | | 2010 RESIDENTIAL 703.6.3. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2014-10-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-10-08 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-10-07 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2014-10-08 07:47:51 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2010 | | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | | | | 1. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE | | | ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER | | | FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED. | | | THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET | | | AT | | | | | | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ | | | 2013/09/SCHEDULE_FOR_INSTALLATION.PDF | | | | | | 2. SHOW THE EMERGENCY MEANS OF ESCAPE, FBC R310.4. | | | INCLUDE THE ROOM DESIGNATION. | | | | | | 3. TWO COMPLETE SETS OF PERMIT DOCUMENTS REQUIRED. ONLY | | | ONE STORM PANEL PRODUCT APPROVAL WAS SUBMITTED, FBC | | | 107. | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-08 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-08 |
Time |
17:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2015-02-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-02-24 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-02-10 |
Time |
11:10 |
Sent To |
B |
|
| Notes |
| 2015-02-11 11:10:32 | TO S. HILL'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2015-01-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-01-20 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-01-13 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2015-01-13 17:45:43 | TO SHILL DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-10-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-10-08 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-18 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2014-09-19 07:25:16 | SENT TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-08 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-08-27 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2014-08-27 09:03:56 | ROUTED TO MISC 1 |
|
|