Plan Review Details - Permit 14081090
Plan Review Stops For Permit 14081090
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2014-12-23 Cont ID  
Sent By jgomez Date 2014-12-22 Time 16:11 Rev Time 0.00
Received By jgomez Date 2014-12-22 Time 16:11 Sent To  
Notes
2014-12-22 16:14:54TALKED TO JOHN (561)818-6979.
  
 BUILDING REVIEW APPROVED WITH PROVISO:
 1- ENGINEER TO REVISE ROOF VENTILATION SPECIFIED ON
 SHEET #4. EIGHT 10" X 10" GOOSE NECK ROOF VENTS DON'T
 PROVIDE 11SQ. FT. OF VENTILATION AS SPECIFIED. R806 OF
 2010 FBC-RESIDENTIAL.
  
 2- PROVIDE COMPLETE ROOFING INFORMATION UNDER A
 SEPARATE PERMIT.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2014-10-01 Cont ID  
Sent By jgomez Date 2014-10-01 Time 10:20 Rev Time 0.00
Received By jgomez Date 2014-10-01 Time 10:17 Sent To  
Notes
2014-10-01 10:23:05RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID
 RECEIPT IF FEES ARE DUE. REQUIRED BY THE COUNTY IMPACT
 FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT CODE.
  
 2- A) NO OPENINGS ARE ALLOWED WHEN THE WALL IS LESS
 THAN 3' FROM THE PROPERTY LINE. TABLE R302.1 OF 2010
 FBC-RESIDENTIAL. REVISE PLANS.
  
 B) EXTERIOR WALL TO BE 1 HOUR FIRE RATED (TESTED IN
 ACCORDANCE WITH ASTM E 119 OR UL 263 WITH EXPOSURE FROM
 BOTH SIDES. TABLE R302.1. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR SUCH 1 HR FIRE RATED WALL.
  
 3- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR ALL DOORS AND WINDOWS AS SHOWN ON PLANS. SPECIFY
 ALL HEADERS. PROVIDE FRAMING DETAILS AND SPECIFICATIONS
 FOR ARCHED OPENINGS AS SHOWN ON PLANS. SEC. R301.1 OF
 2010 FBC- RESIDENTIAL.
  
 4- WALL SECTIONS TO SPECIFY FINISH GRADE TO SHOW
 COMPLIANCE WITH SEC. R404.1.6 AND SEC. R704 OF 2010
 FBC-RESIDENTIAL.
  
 5- SPECIFY ROOF VENTILATION AS REQUIRED BY SEC. R806 OF
 2010 FBC-RESIDENTIAL. CLEARLY SPECIFY IF DESIGNING
 VENTED OR UNVENTED ATTIC AND SHOW COMPLIANCE IN
 DRAWINGS.
  
 6- REVISE SPECIFICATIONS IN ALL WALL SECTIONS. MINIMUM
 STUCCO THICKNESS IS 7/8". TABLE R702.1(1) OF 2010
 FBC-RESIDENTIAL.
  
 7- PROVIDE SPECIFICATIONS FOR THE ROOF SHEATHING
 FASTENING AS REQUIRED BY SEC. R803.2.3.1 OF 2010
 FBC-RESIDENTIAL. SPECIFY THE RING -SHANK NAIL TYPE AND
 SPACING FOR ALL ROOF ZONES.
  
 8- SPECIFY CARBON MONOXIDE ALARMS IN PLANS AS REQUIRED
 BY SEC. R315 OF 2010 FBC-RESIDENTIAL.
  
 9- ENERGY CALCULATIONS SUBMITTED: (NEED AN ACCURATELY
 COMPLETED FORM. SEC. 103.2.1.1.1 OF 2010 FBC-ENERGY
 CONSERVATION).
 A) FORM 402-2010 CAN NOT BE USED. SEE FORM 402-2010
 GENERAL INSTRUCTION #1. EXCEEDS THE 20% GLASS AREA.
 B) SEE GENERAL INSTRUCTIONS #2 AND #3: ALL THE
 INFORMATION ON PAGE 1 IS BASED ON THE INFORMATION ON
 TABLE 402A AND VALUES MUST BE EQUAL TO OR MORE
 EFFICIENT THAN THE REQUIRED LEVELS.
 C) COMPLETE ALL THE INFORMATION ON TOP OF FORM.
 INCLUDING BUILDER, PERMITTING OFFICE AND JURISDICTION
 #.
 D) OWNER/AGENT TO SIGN AND DATE FORM. SEC. 103.2.3.2 OF
 2010 FBC-ENERGY CONSERVATION.
  
 NOTE: THIS IS A CONTRIBUTING HISTORIC HOUSE. IT'S
 EXEMPT FROM THE ENERGY CODE. ENERGY CALCULATIONS ARE
 NOT REQUIRED.
  
 10- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) WINDOW MULLIONS. NOA 10-1115.03 SUBMITTED WITH
 FLORIDA PRODUCT APPROVAL FL15587-R1 EXPIRED ON AUGUST
 19, 2014. NEED TO PROVIDE CURRENT NOA.
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED BY THE
 ENGINEER IN ALL PLANS AND SECTIONS. ***NOTE: PROVIDE
 ONLY THE FLORIDA PRODUCT APPROVAL COVER PAGE AND PAGE
 SHOWING THE CONNECTOR. OR PROVIDE THE FLORIDA PRODUCT
 APPROVAL NEXT TO THE SPECIFIED CONNECTOR.
  
 11- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS,
 INCLUDING THE DOORS, WINDOWS, ETC. AS REQUIRED BY SEC.
 107.3.4.1 OF CITY AMENDMENTS TO FBC.
  
 *** PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 *** PLEASE REMOVE AND REPLACE ALL REVISED SHEETS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2014-12-23 Cont ID  
Sent By skennedy Date 2014-12-23 Time 11:29 Rev Time 0.00
Received By skennedy Date 2014-12-23 Time 11:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2014-09-04 Cont ID  
Sent By sciard Date 2014-09-04 Time 11:59 Rev Time 0.00
Received By sciard Date 2014-09-04 Time 11:59 Sent To  
Notes
2014-09-04 12:26:111ST REVIEW: FBC 2010; NEC 2008
  
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 FBC- 107.3.5.3 ? PROVIDE SMOKE DETECTORS PURSUANT TO
 FBC-R 314.3.1 AS REQUIRED FOR NEW DWELLINGS.
  
 FBC-R 315.1 ? PROVIDE CARBON MONOXIDE ALARMS WITHIN 10
 FEET OF EACH SLEEPING ROOM.
  
 NEC 210.52(A)(1)&(2) OUTLET SPACING, IT APPEARS SOME
 POINTS ALONG THE WALL EXCEED 6? FROM AN OUTLET
  
 N.E.C. 250.104 (3)B BOND OTHER METAL PIPING,GAS PIPING
 AT TANKLESS WATER HEATER.
  
 STEPHEN CIARDIELLO,
 CHIEF ELECTRICAL INSPECTOR
 (561) 805-6743
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2014-09-30 Cont ID  
Sent By fmittner Date 2014-09-30 Time 10:00 Rev Time 0.00
Received By fmittner Date 2014-09-30 Time 09:21 Sent To  
Notes
2014-09-11 15:08:549/11/14

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2014-12-23 Cont ID  
Sent By skennedy Date 2014-12-23 Time 11:31 Rev Time 0.00
Received By skennedy Date 2014-12-09 Time   Sent To  
Notes
2014-12-10 16:44:22INCOMING SENT TO R30.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2014-10-01 Cont ID  
Sent By jgomez Date 2014-10-01 Time 10:23 Rev Time 0.00
Received By jgomez Date 2014-08-25 Time 08:17 Sent To  
Notes
2014-08-26 08:26:55R16

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2015-01-02 Cont ID  
Sent By skennedy Date 2015-01-02 Time 09:46 Rev Time 0.00
Received By skennedy Date 2015-01-02 Time 09:46 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2014-12-23 Cont ID  
Sent By jgomez Date 2014-12-23 Time 08:49 Rev Time 0.00
Received By jgomez Date 2014-12-23 Time 08:49 Sent To  
Notes
2014-12-23 08:49:441- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK COUNTY
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
 REQUIRED BY THE COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2014-10-01 Cont ID  
Sent By jgomez Date 2014-10-01 Time 10:17 Rev Time 0.00
Received By jgomez Date 2014-10-01 Time 10:17 Sent To  
Notes
2014-10-01 10:19:451- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK COUNTY
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
 REQUIRED BY THE COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2014-12-23 Cont ID  
Sent By jgomez Date 2014-12-23 Time 13:49 Rev Time 0.00
Received By jgomez Date 2014-12-23 Time 13:49 Sent To  
Notes
2014-12-23 13:51:4512/23/14 TALKED TO JOHN (561)818-6979.
  
 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS AND
 A/C PLAN UNDER A SEPARATE PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2014-12-23 Cont ID  
Sent By jgomez Date 2014-12-23 Time 07:51 Rev Time 0.00
Received By jgomez Date 2014-12-23 Time 07:51 Sent To  
Notes
2014-12-23 07:58:23RESIDENTIAL (R3) ADDITION, SECOND MECHANICAL REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE EQUIPMENT SIZING CALCULATIONS FOR ENTIRE
 HOUSE INCLUDING THE PROPOSED ADDITION. CALCULATIONS
 SUBMITTED ARE ONLY FOR THE ADDITION AND DON'T SHOW THE
 EXISTING EQUIPMENT SPECIFICATIONS. UNABLE TO VERIFY IF
 THE EXISTING EQUIPMENT IS ADEQUATE FOR THE ADDITIONAL
 LOAD. PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS
 SHOWING ALL THE EXISTING EQUIPMENT SPECS. INFORMATION
 LIKE "GENERIC" IS NOT ACCEPTABLE TO SHOW COMPLIANCE.
 SEC. 107.3.5.3 (10) OF CITY AMENDMENTS TO FBC.
  
 REPEAT COMMENT. CALCULATIONS SUBMITTED DON'T PROVIDE
 ENOUGH INFORMATION TO REVIEW IF THE EQUIPMENT IS
 PROPERLY SIZED FOR THE EXISTING HOUSE AND PROPOSED
 ADDITION. THERE ARE NOT SPECS FOR THE EQUIPMENT. THERE
 IS NO INFORMATION IF THE EQUIPMENT IS EXISTING OR NEW.
 PLEASE PROVIDE COMPLETE INFORMATION TO AVOID DELAYS OR
 CONFLICTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2014-10-01 Cont ID  
Sent By jgomez Date 2014-10-01 Time 10:23 Rev Time 0.00
Received By jgomez Date 2014-10-01 Time 10:23 Sent To  
Notes
2014-10-01 10:23:33RESIDENTIAL (R3) ADDITION, MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- SHEET 7: PROVIDE THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE A/C DESIGN AS REQUIRED BY
 SEC. 107.2.1 OF CITY AMENDMENTS TO FBC.
  
 2- PROVIDE EQUIPMENT SIZING CALCULATIONS FOR ENTIRE
 HOUSE INCLUDING THE PROPOSED ADDITION. CALCULATIONS
 SUBMITTED ARE ONLY FOR THE ADDITION AND DON'T SHOW THE
 EXISTING EQUIPMENT SPECIFICATIONS. UNABLE TO VERIFY IF
 THE EXISTING EQUIPMENT IS ADEQUATE FOR THE ADDITIONAL
 LOAD. PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS
 SHOWING ALL THE EXISTING EQUIPMENT SPECS. INFORMATION
 LIKE "GENERIC" IS NOT ACCEPTABLE TO SHOW COMPLIANCE.
 SEC. 107.3.5.3 (10) OF CITY AMENDMENTS TO FBC.
  
 ***NOTE: SURVEY AND SITE PLAN ON SHEET 1 SHOW THAT THE
 CONDENSER UNIT IS ENCROACHING INTO THE NEIGHBOR'S
 PROPERTY. SEE ZONING COMMENTS AND RESPPOND TO THIS
 ISSUE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2014-12-23 Cont ID  
Sent By tklarge Date 2014-09-17 Time 13:48 Rev Time 0.00
Received By skennedy Date 2014-09-17 Time 13:48 Sent To  
Notes
2014-09-17 13:54:571) SEPARATE PERMIT REQUIRED FOR GAS. MANUFACTURER'S
 SPECIFICATION SHEETS SHALL BE SUBMITTED FOR ALL GAS
 APPLIANCES.TKL.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2014-12-23 Cont ID  
Sent By jgomez Date 2014-12-23 Time 13:33 Rev Time 0.00
Received By jgomez Date 2014-12-23 Time 13:25 Sent To  
Notes
2014-12-23 13:36:1612/23/14 TALKED TO JOHN (561)818-6979.
  
 1- PROVIDE COMPLETE ROOFING INFORMATION UNDER A
 SEPARATE PERMIT.

Review Stop Z ZONING
Rev No 2 Status P Date 2014-12-18 Cont ID  
Sent By fmittner Date 2014-12-18 Time 15:39 Rev Time 0.00
Received By fmittner Date 2014-12-18 Time 15:39 Sent To  
Notes
2014-12-18 15:40:02BACK TO R 30

Review Stop Z ZONING
Rev No 1 Status F Date 2014-10-01 Cont ID  
Sent By fmittner Date 2014-09-30 Time 10:00 Rev Time 0.00
Received By fmittner Date 2014-09-30 Time 10:00 Sent To  
Notes
2014-10-01 13:19:31A/C ON WEST SIDE IS ENCROACHING INTO SETBACK AND
 POSSIBLY NEIGHBORS PROPERTY. ISSUE MUST BE ADDRESSED.
 QUESTIONS, CONTACT FRIEDERIKE MITTNER CITY HISTORIC
 PRESERVATION PLANNER AT 822-1457.
2014-09-30 11:47:18BACK TO R16
2014-09-11 15:09:169/11/14