Plan Review Details - Permit 14080915
| Plan Review Stops For Permit 14080915 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-22 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-22 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2014-09-22 13:04:26 | ****PROVISO**** | | | ****ISSUED AT CONTRACTOR'S RISK**** | | | ****REVISION REQUIRED**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SEE FBC 3103, TEMPORARY STRUCTURES. THE FOLLOWING | | | ITEMS ARE REQUIRED: | | | | | | 3103.2, CONSTRUCTION DOCUMENTS ARE TO INCLUDE | | | INFORMATION DELINEATING THE MEANS OF EGRESS AND | | | OCCUPANT LOAD. PLAN IS NOT CLEAR AND OCCUPANT NOT LOAD. | | | SUBMIT AS A REVISION. | | | | | | 3103.3, TEMPORARY STRUCTURES SHALL BE LOCATED IN | | | ACCORDANCE WITH THE REQUIREMENTS OF TABLE 602. IT IS | | | NOT CLEAR WHETHER THIS IS ATTACHED TO AN EXISTING | | | BUILDING OR FREE STANDING, AND IF IT IS ATTACHED TO AN | | | EXISTING BUILDING, HOW THE PROPOSED TENT WILL AFFECT | | | THE EXITING FOR THE EXISTING BUILDING. | | | | | | 3103.4, EXIT ACCESS TRAVEL DISTANCE NOT TO EXCEED 100 | | | FEET. | | | | | | PROVIDE A LIFE SAFETY PLAN WHICH SHOWS OCCUPANT LOAD, | | | EXITING, TRAVEL DISTANCE, FBC CHAPTER 10. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2014-09-11 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-11 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-11 |
Time |
16:40 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-09-02 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-02 |
Time |
09:38 |
Sent To |
B |
|
| Notes |
| 2014-09-02 09:44:45 | DATE: 9/2/2014 | | | PROJECT: IBIS TEMP TENT | | | PERMIT#: 14080915 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) THERE IS NO ELECTRICAL INFORMATION INCLUDED IN | | | SUBMITTAL PACKAGE. PLEASE PROVIDE THE MINIMAL PLAN | | | REVIEW CRITERIA TO INCLUDE BUT NOT BE LIMITED TO THE | | | FOLLOWING: | | | A. A RISER DIAGRAM, LOAD CALCULATION, AND PANEL | | | SCHEDULE(S) | | | B. A FLOOR PLAN INDICATING GENERAL LIGHTING, LIGHTING | | | CONTROL, EMERGENCY AND EXIT LIGHTING, PROVIDING A SAFE, | | | ILLUMINATED MEANS OF EGRESS. | | | C. THE FLOOR PLAN TO ALSO INDICATE GENERAL POWER | | | OUTLET(S) GFI(S) EQUIPMENT LOCATIONS, INCLUDING LOAD | | | AND VOLTAGE, WIRING METHODS, AND CONNECTION DETAILS | | | INDICATING DISCONNECTS AS REQUIRED, | | | D. A SITE PLAN TO INCLUDE LOCATIONS FOR UTILITIES, | | | ELECTRICAL SERVICE EQUIPMENT, AIR CONDITIONING UNITS | | | WITH ASSOCIATED WIRING AND DISCONNECTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT | | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | | ITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2014-09-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-09-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-09-12 |
Time |
13:55 |
Sent To |
B |
|
| Notes |
| 2014-09-12 14:14:37 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE APPROVAL IS CONTIGENT ON VERIFICATIONS FROM A SITE | | | FIRE INSPECTION BY A WEST PALM BEACH FIRE INSPECTOR. | | | | | | THE OCCUPANCY LOADS SHALL BE VERIFIED AND OCCUPANCY | | | LOADS SIGNS SHALL BE INSTALLED. | | | | | | EXIT SIGNS AND EMERGENCY LIGHTING SHALL BE VERIFIED. | | | THE FIRE INSPECTOR RESERVES THE AUTHORITY TO ADD EXIT | | | SIGNS AND/OR EMERGENCY LIGHTING AS NEEDED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2014-08-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-08-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-08-21 |
Time |
12:11 |
Sent To |
E |
|
| Notes |
| 2014-08-21 12:44:22 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | THE PROPOSED LOCATION OF THE TENT WAS NOT, IS NOT, | | | DESIGNED FOR THIS TYPE OF OCCUPANCY OR STRUCTURE. | | | | | | IN THE EVENT OF AN EMERGENCY IN THE EXISTING BUILDING | | | AND/OR IN THE PROPOSED TENT STRUCTURE, THE OCCUPANTS | | | SHALL BE AFFORDED A CLEAR, SAFE EXIT PATH, EXIT DOOR | | | AND EXIT DISCHARGE LEADING TO A PUBLIC WAY. | | | | | | NO EXITS, EXIT DISCHARGES, OR EMERGENCY LIGHTS ARE | | | IDENTIFIED ON THE PLAN. THE WORD "DOOR" IS ON THE PLAN; | | | HOWEVER, THE SIZE OF THE DOOR IS NOT INDICATED OR THE | | | TYPE OF EXIT DOOR HARDWARE THAT IS REQUIRED FOR THIS | | | ASSEMBLEY OCCUPANCY. | | | | | | NOT EXIT PATH LEADING TO A PUBLIC WAY FROM THE EXIT | | | DISCHARGE (DOOR) IS NOT IDENTIFIED ON THE PLAN. | | | | | | A LIFE SAFETY PLAN, INCLUDING ALL EXITS, EXIT PATHS, | | | CORRIDORS, EXIT DISCHARGES, OCCUPANCY LOADS, EMERGENCY | | | LIGHTING SHALL BE PROVIDED. | | | | | | A COMPREHENSIVE LIFE SAFETY PLAN THAT INCLUDES THE | | | EXISTING BUILDING'S OCCUPANY LOADS, EXIT PATHS, AND | | | EXIT DISCHARGES OF THE SURROUNDING STRUCTURES, | | | INCLUDING FENCING, MUST BE CONSIDERED, PLANNED FOR AND | | | SUBMITTED FOR APPROVAL. | | | | | | THE SEATING PLAN IS NOT APPROVED AND MUST BE SUBMITTED | | | SEPARATLY, INLUDING ALL DIMENSIONS BETWEEN CHAIRS AND | | | TABLES AND ENSURING A CLEAR AND CONTINUOUS EXIT PATH | | | LEADING TO AN EXIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2014-09-22 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2014-09-09 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2014-09-11 16:41:54 | MISC. 2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-02 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-02 |
Time |
10:16 |
Rev Time |
|
| Received By |
dhayes |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2014-08-21 10:35:13 | ROUTED TO FIRE (TWO APPLICATIONS ARE TOGETHER IN THIS | | | PACKAGE ONE FOR THE TEMPORARY TENT AND ONE FOR THE | | | ELECTRICAL) |
|
|
|