Plan Review Details - Permit 14080799
| Plan Review Stops For Permit 14080799 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2014-09-10 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-10 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-10 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2014-08-26 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-26 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-26 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2014-08-26 15:35:59 | DATE: 8/26/2014 | | | PROJECT: POTTER | | | PERMIT#: 14080799 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 2ND ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | DUPLICATE COMMENTS: | | | 1) PROVIDE A SITE PLAN TO INDICATE THE LOCATION OF THE | | | ELECTRICAL PANEL TO BE CHANGED TO ILLUSTRATE THE | | | REQUIRED SERVICE ENTRANCE OVER CURRENT PROTECTIVE | | | DEVICE AS PER NEC 230.91 LOCATION. | | | REVISE THE RISER DIAGRAM TO INDICATE THE LOCATION OF | | | THE MAIN DISCONNECT (SERVICE OCPD) | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT | | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | | ITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-19 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-19 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2014-08-19 13:52:31 | DATE: 8/19/2014 | | | PROJECT: POTTER | | | PERMIT#: 14080799 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: DENIED | | | | | | 1) THE GROUNDING ELECTRODE CONDUCTOR INDICATED ON THE | | | PLANS IS UNDERSIZED. PRODIDE ADAQUATE GEC SIZE PER NEC | | | 250.66. | | | | | | 2) PROVIDE A SITE PLAN TO INDICATE THE LOCATION OF THE | | | ELECTRICAL PANEL TO BE CHANGED TO ILLUSTRATE THE | | | REQUIRED SERVICE ENTRANCE OVER CURRENT PROTECTIVE | | | DEVICE AS PER NEC 230.91 LOCATION. | | | REVISE THE RISER DIAGRAM TO INDICATE THE LOCATION OF | | | THE MAIN DISCONNECT (SERVICE OCPD) | | | | | | 3) REVISE THE VALUATION OF THE PROJECT INDICATED ON THE | | | PERMIT APPLICATION AND PROVIDE SUPPORTING DOCUMENTATION | | | FOR THE VALUATION OF THE PROJECT ON THE APPLICATION. | | | INCLUDE ALL LABOR MATERIAL, SUB CONTRACTS ASSOCIATED | | | UTLITY COSTS OVERHEAD PROFIT ETC... FBC WPB AMENDMENTS. | | | SECTION 109.3 | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. SEE LINK: | | | HTTP://WPB.ORG/DEVELOPMENT | | | /WP-CONTENT/UPLOADS/SITES/33/2013/09/APPLICATION_RESUBM | | | ITTAL_FORM_04132010.PDF | | | | | | ADDITIONALLY, PLEASE INSERT CORRECTED PAGES INTO | | | SUBMITTAL PACKAGE AND LEAVE THE PREVIOUSLY REVIEWED | | | SHEETS FOR COMPARATIVE REVIEW. | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-29 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2014-08-26 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-26 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-22 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2014-08-25 08:46:01 | RE-SUBMITTAL SENT TO DAVID HAYES' DESK FOR REVIEW. JG. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-08-19 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-18 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2014-08-18 15:01:41 | ROUTED TO ELECTRICAL $5000 & UNDER |
|
|
|