Plan Review Details - Permit 14080726
| Plan Review Stops For Permit 14080726 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-27 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-27 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-08 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-09-08 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2014-09-08 09:32:26 | DATE: 9/8/2014 | | | PROJECT: ADS DIRECT | | | PERMIT#: 14080726 | | | CODE: 2008 EDITION OF THE NEC | | | 2010 EDITION OF THE FBC | | | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, | | | ADMINISTRATION, 2012 FBC SUPPLEMENTS. | | | | | | 1ST ELECTRICAL PLAN REVIEW | | | ACTION: PROVISO | | | | | | 1) MAINTAIN STRUCTURAL AND FIRE RATING INTEGRITY OF | | | FLOOR WHEN PENETRATING WITH FLOOR BOXES. USE APPOVED | | | FIRE RATED POKE THROUGH BOXES. NEC, 110.3, 314.27(C) | | | | | | 2) MAINTAIN SEPARATION OF POWER AND DATA/COM CABLING | | | WHEN INSTALLING FLOOR BOXES. USE BOXES APPROVED FOR | | | THIS USE. NEC, 110.3, 314.27(D) | | | | | | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, | | | 561-805-6717 OR [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2014-08-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2014-08-19 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
dhayes |
Date |
2014-09-08 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
dhayes |
Date |
2014-08-15 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2014-08-18 08:52:09 | SENT TO B3 SHELF FOR REVIEW. JG. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-27 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-27 |
Time |
07:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2014-08-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2014-08-19 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2014-08-19 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2014-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2014-08-27 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2014-08-27 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2014-09-08 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2014-08-26 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2014-08-26 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
|