| 2014-08-15 08:03:41 | DATE: 8/15/2014 |
| | PROJECT: NALBANDIAN 400 N. FLAGLER |
| | PERMIT#: 14080626 |
| | CODE: 2008 EDITION OF THE NEC |
| | 2010 EDITION OF THE FBC |
| | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER 1, |
| | ADMINISTRATION, 2012 FBC SUPPLEMENTS. |
| | |
| | 1ST ELECTRICAL PLAN REVIEW |
| | ACTION: DENIED |
| | |
| | 1) WHEN ALTERATIONS, REPAIRS, OR ADDITIONS REQUIRING A |
| | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE |
| | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL |
| | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS |
| | LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC-RESIDENTIAL |
| | 314.3 AND 314.3.1. INDICATE LOCATION OF NEW AND/OR |
| | EXISTING SMOKE DETECTORS AND SUBMIT WITH ASBUILTS. |
| | |
| | 2) LUMINAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED IN |
| | ACCORDANCE WITH THE PROVISIONS OF THE NEC 410.16(A) AND |
| | (B). INDICATE THE LOCATION OF THE FIXTURES IN THE |
| | CLOTHES CLOSETS AND SUBMIT WITH ASBUILTS |
| | |
| | 3) METAL FRAMING MEMBERS SHALL BE BONDED TO THE |
| | EQUIPMENT GROUNDING CONDUCTOR FOR THE CIRCUIT THAT MAY |
| | ENERGIZE THE FRAMING AND BE SIZED IN ACCORDANCE WITH |
| | THE NEC TABLE 250.122. FOR THE PURPOSE OF THIS SECTION, |
| | A GROUNDED METAL OUTLET BOX ATTACHED TO THE FRAMING |
| | SHALL BE PERMITTED. AS REQUIRED. |
| | |
| | 4) ALL NEW GENERAL PURPOSE OUTLETS MUST BE TAMPER |
| | RESISTANT AND AFCI PROTECTED. NEC 210.12, NEC 406.11. |
| | INDICATE NOTE TO INCLUDE TAMPER RESISTANT RECEPTACLES |
| | AND SUBMIT WITH ASBUITS. |
| | |
| | 5) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND |
| | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF |
| | THE PERSON RESPONSIBLE FOR THE DESIGN. WPB AMENDMENTS |
| | TO FBC 107.2.1. SIGN PLANS AND SUBMIT WITH ASBUILTS. |
| | |
| | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, |
| | 561-805-6717 OR [email protected] |
| | |